Proposed Tech Specs Re Surveillance Interval Extension for Type B & C Leak Rate Testing & two-yr Interval Exemption from 10CFR50,App J
ML20064G404
Person / Time
Site: Cook 
Issue date: 03/09/1994
From:
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
Shared Package
ML17331B294 List:
References
AEP:NRC:1204, NUDOCS 9403160177
Download: ML20064G404 (4)


Text

.-

i-ATTACHMENT 2 TO AEP:NRC: 1204 EXISTING TECHNICAL SPECIFICATION PAGE MARKED TO REFLECT PROPOSED CHANGES i

l 3

-1 9403160177 940309 3

PDR ADOCK 05000316 P

PDR

4 CONTAINMENT SYSTEMS SURVEILLANCE REQUIREMENTS ( Cont inued }_

b.

If any periodic Type A test fails to meet.75 L,,

the test schedule for subsequent Type A tests shall be reviewed and approved by the Commission.

If two consecutive Type A tests fail to meet.75 L", a Type A test shall be' performed at least every 18 months until two consecutive Type A tests meet.75 L,, at which time the above test schedule may be resumed.

c.

The accuracy of each Type A test shall be verified by a supple-mental test which:

1.

Confirms the accuracy of the Type A test by verifying that the difference between supplemental'and Type A test data is within 0.25 L,,

2.

Has a duration sufficient to establish accurately the change in leakage between the Type A test and the supplemental test.

3.

Requires the quantity of gas injected into the contain-ment or bled from the containment during the supplamental test to be equivalent to at least 25 percent of the total measured leakage rate at P, 12.0 psig.

)

d. Type B and C tests shall be conducted at P, 12.0 poig, at intervals no greater than 24 months except for tests involving air locks.i l.

e.

Each containment air lock shall be verified to be in compliance g

with the requirements of Specification 3.6.1.3.

f. All test leakage rates suall be calculated using observed data converted to absolute values.

Error analyses shall be performed to select a balanced integrated leakage measurement system.

l g.

The provisier.s of specification 4.0.2 are not applicable.

i Dwc_idge eum do lo cSR co, Appen E khs E b,ZN ud a u, w a a u s em r * ~ 4 L 6 d 4 h u.o.e e

to 6 appl lc~ W.

)

COOK NUCLEAR PLANT - UNIT 2 3/4 6-3 AMENDMINT NO. N

4 1

l ATTACitMENT 3 TO AEP:NRC.1204 PROPOSED REVISED TECHNICAL SPECIFICATION PAGE 4

l

, I b

u='

ym

.g n

W.gn, 9

e1 mw,4

.*-+- -

,+-

r...

CONTAINMENT SYSTEME EMRVEILLANCE REOUIREMENTS (Continued) b.

If any periodic Type A test fails to meet 75 L.,

the test schedule for subsequent Type A tests shall be reviewed and' approved by the Commission.

If two consecutive Type A tests fail to meet.75 L., a Type A test shall be performed at least every 18-months until two consecutive Type A tests meet.75 L,, at which time the above test schedule may' be resumed, c.

The accuracy of each Type A test shall be verified by a supple-mental test which:

1.

Confirms the accuracy of the Type A test by verifying -

that the difference between supplemental and Type A test data is within 0.25 L.,

2.

lias a duration sufficient to establish accurately the change in leakage between the Type A test and the supplemental test.

3.

Requires the quantity of gas injected into the contain-ment or bled from the containment during.the supplemental test to be equivalent to at least 25 percent of the total measured leakage rate at P.,

12.0 psig.

d.

Type B and C tests shall be conducted at P,12.0 psig, at intervals no greater than 24 months except for tests involving air locks.t l-e.

Each containment air lock shall be verified to be in compliance with the requirements of Specification 3.6.1.3.

f.

All test leakage rates shall be calculated using observed data converted to absolute values.

Error analyses shall be performed H

to select a balanced integrated Icakage measurement system.

2 The provisions of Specification 4.0.2 are not applicable.

t

.One-time exemption to 10 CFR 50, Appendix J, Sections III.D.2(a) and III.D.3, which allows the. provisions of Technical Specification 4.0.8

'to be applicable.

COOK NUCLEAR PIANT - UNIT 2 3/4 6-3 AMENDMENT NO. 444