ML20063P735

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re ASME III Class 1 Joints Welded W/Asme Class 2 & 3 Welding Procedures.Contrary to ,Deficiency Deemed Reportable Per 10CFR50.55(e)
ML20063P735
Person / Time
Site: Nine Mile Point Constellation icon.png
Issue date: 10/06/1982
From: Manno S
NIAGARA MOHAWK POWER CORP.
To: Starostecki R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
10CFR-050.55E, 10CFR-50.55E, NUDOCS 8210150129
Download: ML20063P735 (1)


Text

.  ?

Y NIAGARA o

  • NUMOHAWK NIAGARA MOHAWK POWER CORPORATl0N/300 ERIE BOULEVARD WEST, S' RACUSE, N.Y.13202/ TELEPHONE (315) 4741511 CAMUEL F. MANNO V'CE PRLSIDENT NLCLE AR CONSTRUCTION October 6,1982 Office of Inspection and Enforcement Region I Attention: Mr. R. W. Starostecki, Director Division of Project and Resident Programs U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, PA 19406 Re: Nine Mile Point - Unit 2 Docket No. 50-410 -

Dear Mr. Starostecki:

Our letter of August 31, 1982 indicated that certain ASME III Class 1 joints which were welded using ASME III Class 2 and 3 welding procedures were not reportable in accordance with 10CFR50.55(e). Based upon the September 27, 1982 discussion with Mr. Kister of y.our staff and a review by our staff, Niagara Mohawk wishes to modify the August 31, 1982 letter.

Specifically, the above mentioned matter is reportable within the requirements of 10CFR50.55(e). Corrective action was discussed in the August 31, 1982 letter.

Very truly yours, S. F. Manno Vice President, Nuclear Construction 1

SFM/ jab l

8210150129 821006 PDR ADOCK 05000410 A S PDR g(y

-. - . - -