DAL Carolina Power & Light Company SEP 071982 Office of Nuclear Reactor Regulation ATTN:

Mr. D. B. Vassallo, Chief Operating Reactors Branch No. 2 United States Nuclear Regulatory Commission Washington, D.C.

20555 BRUNSWICK STEAM ELECTRIC PLANT, UNIT NOS. 1 AND 2 DOCKET NOS. 50-325 AND 50-324 LICENSE NOS. DPR-71 AND DPR-62 REQUEST FOR LICENSE AMENDMENT -

MISCELLANEOUS TECilNICAL SPECIFICATION REVISIONS

Dear Mr. Vassallo:

SUM:1ARY In accordance with the Code of Federal Regulations, Title 10, Part 50.90 and Part 2.101, Carolina Power & Light Company (CP&L) hereby requests revisions to the Technical Specifications (TS) for the Brunswick Steam Electric Plant (BSEP) Unit Nos. I and 2.

DISCUSSION A review of the Brunswick TS has identified certain TS items for which revisions are needed. These revisions (1) provide a clarification of certain TS requirements, (2) provide editorial and/or administrative corrections of certain TS requirements, and (3) provide TS changes to reflect consistency with the actual plant design. The revisions are discussed in detail in the attachments.

ADMINISTRATIVE INFORMATION Enclosed are separate sti.achments for the proposed TS ravisions, each of which includes a discussion of the unit-specific applicability, a description of the item changed, the basis for the proposed change, and retyped TS pages reflecting the proposed revisions. The revisions on the enclosed TS pages are indicated by vertical lines in the right-hand margin.

We have evaluated this request in accordance with the criteria in 00 10 CFR 170.22 and have determined that this submittal constitutes a Class IV and a Class I license amendment request for Brunswick-1 and Brunswick-2, respectively. Therefore, our check for $12,700 is enclosed in payment of the required fees.

Y I 1,70 *#

411 Fayetteville Street

  • P. O. Box 1551
  • Raleigh, N C. 27602

""**N*"

=aM 8209100221 820907 PDR ADOCK 05000324 P

PDR a

l Should you have any questions concerning this submittal. please contact our staff.

i l

Yours very truly, 1

.U' P. W. Howe Vice President Technical Services WRM/cr (4028C6T5)

Enclosures P. W. Howe, having been first duly sworn, did depose and say that the information contained herein is true and correct to his own personal knowledge or based upon information and belief.

Att WT1 t 1/

Notary (Seal) o,,f[,,t, OCT 041986 g g My commission expires:

cc:

Mr. D. O. Myers (NRC-BSEP)

Mr. J. P. O'Reilly (NRC-RII)

E [goTARyt 5 p U B t.1C l!

E Mr. J. A. Van Vliet (NRC)

E j

5 5 5 e..Ohkk ' s

/

3 ATTACHMENT 1 S UBJECT: Remote Shutdown Monitoring Instrumentation APPLICABILITY: Unit I and Unit 2 DESCRIPTION OF TECHNICAL SPECIFICATION (TS) CHANGE: Technical Specification Table 4.3.5.2-1, Remote Shutdown Monitoring Instrumentation Surveillance Requirements, Item 2, Reactor Vessel Water Level: Revise the monthly channel check to "Not Applicable" for instruments B21-LT-N017D-3 and B21-LSH-N017D-3.

i l

BASIS FOR CHANGE: Transmitter B21-LT-N017D-3 and its associated level switch B21-LSH-N017D-3 provide an input to bistable logic and dc)_ not provide a signal to an indicator; therefore, the requirement for a channel check for these instruments is not appropriate. The requirement for a monthly channel check should be revised to "Not Applicable." The requirement for a quarterly channel calibration should remain unchanged.

i i

i l

l I

- - -