Text
v
+,
==
Log # TXX-94030 File # 10010.1
~
905.4 (clo)
C C
Ref. # 10CFR50.55(a)(g)
TUELECTRIC William J. Cubill, Jr.
Govup Vice Presoderut U. S. Nuclear Regulatory Commission Attention:
Document Control Desk Washington, DC 20555
SUBJECT:
COMANCHE PEAK STEAM ELECTRIC STATION (CPSES) - UNIT 1 DOCKET NO. 50-445 TRANSMITTAL OF INSERVICE INSPECTION PROGRAM PLAN INTERIM CHANGE REQUEST NO. ISI-1R2-006 Gentlemen:
Enclosed is the following document to update your copy of the CPSES Unit 1 Inservice Inspection Program Plan:
Interim Change Request No. ISI-1R2-006 This transmittal is for the purpose of a manual update only.
If you have any questions regarding the change, please contact Mr. C. B. Corbin at (214) 812-8859 or Mr. R. B. Mays at (817) 897-6816.
Sincerely, William J. Cahill, Jr.
By:
D. R. Woodlan Docket Licensing Manager CBC/vid Enclosure c-Mr. L. J. Callan, Region IV Resident Inspectors, CPSES Mr. T. A. Bergman, NRR Mr. G. Bynog, TDLR
'l
/
9402040136 940126 F
~
PDR-ADOCK 0500 5
6 m m m o m m mi
s
- a r.
a, i
5 F
4 5
f-I I
e n-4 s
i t
k t
i i
b h
t m
. i
- i I
b Enclosure to TXX-94030 l
1
. \\
l l
1 l
l l
. 1 t
...i.-..,-._,-. - - -..
.re.
.m--.*L---~5---.----+.e+----e-,-
e.* - -==,' - =.
4*r, w
w~-.*
r-'~+=r-1
'-w'"*w-Y i
-Tm-***
r-* r r
+*
i.
n1UELECTRIC
/ +;
N.)
OFFICEMEMORANDUbi CPSES-9400562 January 18,1994 TO:
Diane Bleeker - M21
SUBJECT:
CPSES UNIT 1 INSERVICE INSPECTION PROGRAM PIAN REVISION 2, INTERIM CHANGE 6 In accordance with paragraph 6.1.3 of STA-703, " Inservice Inspection Program", distribution of the subject document shall be made as follows:
No. of Conies Resn. for Change Nuclear Regulatory Commission Document Control 2*
C. Cortin-ST24 Region 1*
Resident 1*
Texas Department of Licensing and Regulation 1*
Dallas Licensing 2*
C. Corbin 1*
Manford Steam Boiler (ANII-sate) 1 J. C. Hair - 006 SSB Ubrary 1
A08 Qualr4 Control 1
B. R Snellgrove - M38
/]
Mechanical Codes and Standards 1
J. DeBonis - 006 V
Operations DCC 1
OOGA CDCCIlbrary 1
F04A
=
CDCC Procedures 1
F04 Engineering Library 1
FO4 Perfortnance & Test 1
M. W. Sunscri - M35 Please ensure that each copy holder receives the appropriate number of copies along with a copy of this letter. The copies denoted by "*" shall be distributed by Dallas Licensing. Each copy of the attached document shall be inserted as a page replacement to the applicable plan.
If you have any questions, please call John DeBonis at extension 8707.
R. B. Mays - 006 Codes and Standards Engineering Supervisor JFD:Jcc Attachment cc:
CCS E06 (IL)
R D Walker ST24 (IL)
f'l
~
~
~
n tu,m oi,e copy y INTERIM CHANGE REOUEST O
7/dd 84#,
2*
Plan Tirle/Rev. /1/
ICR No.
Reference:
Page - ll6 Table - 9 Relief Request, and/or Component: La wo' 5 IB -F*l- 04 M 010 - l'$o3-2.-
Reason for Change:
g of the Esr Plan 6 clocument. t/s e o'eSeri ec)
Repair / Rep /aeement Aydro s in Ge. tes t-af tie
<ys o,'.g
/8 fW-t-ol8 a& e2 0 - 19 0 3 ~ 2-.
Proposed Revision:
Rep / ace a vii Ung secbon Q ro w 7, p9e //s wl9, e,e A
atta ch ed' &6le 9, page //L wish* y seeban C m,ks eme with %g.
- Replace se n
a.bl& e f Sedon S vo*te.s f>qa.,
a
- Rep ace the 41iWn9 /?ppend'sx B ps 2 wlh atipehe/ Arp 6, eg3, f
s run;s %vM iviecA cr's ihe /W Initia6cf Department Date N at/>
/~20ff Approved: %} Yes
[] No 4-CodesandStand/rdsfpptvisor Date Reason for Disapproval:
STA-703-5 Page 1 of 1 R0
06/01/93 UNIT 1 ASME SECTION XI INSERVICE PRESSURE TEST LINE LIST TA8LE 9 ASME Exas Test Type Exas Test Test REC Line/ Component No.
Flow Dia8 ram No.
Ites CAT Freq.
Test Method Pressure Temp.
Notes /Comunents NO.
.===============================
= = = = = = = = = = = = = = = = =
==
=
==
=
==
= = = = =
==
= = = = = = = = = = =
=
- FEEDWATEN (FW) FW-1-017-1303-2 M1-0203-1A C7.30 C-H P
Sif VT 2 Po To 345 C7.40 I
SNT TA8LE 4 TABLE 5 18-FW-1-018-1303-2 M1-0203-1A C7.30 C-N P
Sli VT-2 Po To fe e-344 gg g C7.40 I
SNT TABLE 4 TA8LE 5 ICA-6 18-FW-1-010-1303-2 M1 0203-1A C7.30 C-N P
Sli VT-2 Po To 347 C7.40 I
SNT TA8LE 4 TA8LE 5 18 FW-1 020-1303-2 M1 0203-1A C7.30 C-N P
SIT VT-2 Po To 600-348 yo75 6 C7.40 1
SNT TABLE 4 TABLE 5 p.,
1 1/2-FW-1-030-1303-2 M1-0203-1 CT.30 C-N P
SIT VT-2 Po To EXEMPT DNSTRM 349 ry.156 C7.40 I
SNT TABLE 4 TABLE 5 1 1/2-FW 1-031-1303-2 M1-0203-1 C7.30 C-H P
SIT VT-2 Po To EXEMPT DNSTRM 350 FW-157 C7.40 1
SNT TABLE 4 TABLE 5 1 1/2-FW-1-032-1303-2 M1-0203-1 C7.30 C-N P
SIT VT-2 Po To EXEMPT DNSTRM 351 ry.153 C7.40 1
SNT TABLE 4 TAsLE 5 1 1/2 FW-1-033-1303 2 M1 0203 1 CT.30 CN P
SIT VT-2 Po To EXEMPT DNSTRM 352 ry.159 C7.40 I
SNT TABLE 4 TABLE 5 18-FW-1-034-2003-2 M1-0203-1 C7.30 C-N P
SNT TABLE 4 TABLE 5 18-FW-1-035-2003-2 M1-0203-1 C7.30 C-N P
SNT TA8LE 4 TA8LE 5 18-FW-1-036-2003-2 M1 0203-1 C7.30 C-N P
SNT TABLE 4 TA8LE 5 4
O O
O
,.d
. TCR. ~ J S t - IK%. - O O co
~
P & %>[y NOTES:
1.
Storage tank or extension of storage tank.
2.
Containment isolation piping.
3.
Demonstration of an open flow path test shall be performed in lieu of the system hydrostatic test.
4.
Confirmation of adequate flow during system operation shall be performed in lieu of system hydrostatic test.
5.
See Relief Request D-1.
6.
Those portions of the reactor coolant (RC) system main coolant loop piping between the reactor vessel and the outer portion of the missile shield are considered inaccessible. The outer surface of the shield wall shall be examined for evidence of leakage.
7.
The Repair / Replacement hydrostatic test for BRP-CT-2-SB-027, Sht.1, welds 17 p
and 18A and for BRP-CT-2-SB-011, Sht.1, weld 3A is deferred until this y
regularly scheduled system hydrostatic test as permitted by Code Case N-416.
Reference Work Order 1-93-052173-00 and DCN 6740 Rev. O.
t 8.
The Repair / Replacement hydrostatic tests for BRP-FW-1-SB-018, Sht.1, weld 6
I TU1-23 and for BRP-FW-1-SB-020, Sht.1, weld TU1-25 are deferred until these regularly scheduled system hydrostatic tests as permitted by Code Case N-416.
}
Reference Work Orders 1-92-002158-00 and 1-92-002160-00.
Section 5 Notes - Page 1
a ; ;. t _. ';.
....j_c-
.1r8 -ist R2 ~ **"ps M c4 t{
~
ISI-1R2-002 ~
' Appendix C Add Code Case N-416 :
j
" Alternative Rules for Hydrostatic Testing of Repair i
or Replacement of Class 2 -
' Piping" Section 5 Add reference to Note 7 on
' i
~
Table 9 page 100 and add Note 7 to i
note page.
-i ISI-1 R2-003 Section 2 Revised the following
]
drawings:
j CC - Sh. 3 q
DO - Sh.1, 2 SI - Sh. 7, 8, 9 Section 5 Replace the following
=
pages from Table 9:
j 58,86, 96,'101,-102,107, 110,112,113,149,158 1
ISI-1 R2-004 Appendix C Add Code Case N-457
" Qualification Specime;n
- Notch Location for Ultrasonic-r Examination'of Bolts and Studs"
]
Section 4.1 Replace the following pages:
51,52,53 Add the following pages:
37.1,45.1, 51.1,62.1-i ISI-1R2-005 Section 4.1,4.2 Replace pager,:
'l
'4-2,9,11.16,17,19,24,25, 26,31,32,39,54,140,145,-
j 147,'189,190,191,261,262, j
.265,266 l
Add page'54.1,93.1,96.1, 96.2 i
e ISI-1 R2-006
~ Section 5
' Add reference to Note 8 on
'i Table 9 page 115 and add Note 8 to i
note page.
O Appendix B - Page 3 j
_ =