Docket N . 50-305
i
f
- .:
Wisconsin Pu
Service
.
l
Corporation
ATIN:
Mr. E. W. James
i
Senior Vice President
Power Generation and
Engineering
Post Office Box 1200
,
Green Bay, WI 54305
Gentlemen:
This refers to the inspection conducted by Messrs. J. R. Creed and
J. C. Howell of this office on Nove=ber 27-December 1,1978, of
I
activities at the Kewaunee Nuclear Power Plant' authorized by KRC
Operating License No. DPR-43 and to the discussion of our findings
with Messrs. M. Stern, G. Ruiter, C. Luoma, T. Moore and D. Raine
at the conclusion of the inspection.
The enclosed copy of our inspection report identifies areas
i
examined during the inspection. Within these areas, the
!
inspection consisted of a selective examination of procedures
and representative records, observations, and interviews with
personnel.
During this inspection, certain of your activities appeared
,
to be in noncompliance with NRC requirements, as described
in the enclosed Appendix A.
t
(
This notice is sent to you pursuant to the provisions of'Secticn
2.201 of the NRC's " Rules of Practice," Part 2, Title 10, Code
.
j
of Federal Regulations. Section 2.201 requires you to submit to
j
this office within twenty days of your receipt of this notice a
'
written statement or explanation in reply, including for each
I
item.of noncompliance: (1) corrective action taken and the results
achieved; (2) corrective action to be taken to avoid further ncn-
compliance; and (3) the date when full compliance will be achieved.
I
!
!
,
s
7 9 0 2 010 3c/o
.
. -
.
.
.
.
.
.. ..
.
. .
. .
.
. - - . ~.
,
-
\\
2
1
Wisconsin Public Service
-2-
Corporation
Areas examined during this inspection concern a subject matter
which is exempt from disclosure according to Section 2.790 of
theNRC's"Rulesoffractice,"Part 2 Title 10, Code of Federal
Regulations. Consequently, the enclosure to this letter, our
_
ri
report of this inspe'ction, and your response to the noncompliance
~
,7
identified in the enclosure to this letter will not be placed in
the Public Document Room. Therefore, your statement of corrective
action regarding the noncompliance identified in the enclosure
should be submitted as a separate enclosure to your transmittal
letter.
We will gladly discuss any questions you have concerning this
inspection.
Sincerely,
,gf.f'
-
J. A. Hind, Chief
Safeguards Branch
Enclosures:
1.
Appendix A, Notice
of Violation
2.
IE Inspection Report
No. 50-305/78-23
(Part 2.790(d) Information)
cc w/encls:
Mr. C. Luoma, Plant
Superintendent
Central Files
Reproduction L' nit NRC 20b
cc w/o encls:
Local PDR
t
I
1