ML20062F307
| ML20062F307 | |
| Person / Time | |
|---|---|
| Site: | Brunswick |
| Issue date: | 08/03/1982 |
| From: | Harrison F CAROLINA POWER & LIGHT CO. |
| To: | |
| Shared Package | |
| ML20062F305 | List: |
| References | |
| NUDOCS 8208120016 | |
| Download: ML20062F307 (11) | |
Text
I l
9 APFENDIX B AVERAGE LPJLY POWER LEVEL DOCKET NO. 059-03i5 UNIT BRUNSWICK UNIT 1 DATE G8/03/82 COMPLETED DY FRANCES HARRISCN TELEPHONE 919-407-9521 l
JULY 82 l
l DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY c'0WER LEVEL l
(MWE-NET)
(MWE-Nd-)
1 606.
17
-12.
f 2
596.
18
-8.
3 593.
19
-8.
1 l
4 591.
20
-8.
l 5
589.
21
-8.
l 6
587.
22
-10.
7 582.
23
-9.
8 580.
24
-8.
9 576.
25
-8.
10 335.
26
-9.
11 70.
27
-10, 12 495.
28
-9.
13 600.
29
-10.
14 571.
30
-10.
15 479.
31
-10.
16 433.
1.16 - 8 8208120016 820804 PDR ADOCK 05000324 R
PDR d
.. - -. - - - ~. - - - - - - -..
i l
l
.i OPERATING DATA REPORT I
DOCKET NO. 050-0325 DATE 08/03/82 COMPLETED BY FRANCES HARRISON i
TELEPHONE 919-457-9521 OPERATING STATUS 1.
UNIT NAME: BRUNSWICK UNIT 1 I NOTES I
- 2. REPORTING PERIOD: JULY 82 I
I
- 3. LICENSED THERMAL POWER (MWT): 2436 I
I
- 4. NAMEPLATE RATING (GROSS MWE): 867.0 I
I
- 5. DESIGN ELECTRICAL RATING (NET MWE): 821.0 I
I l
6.
MAX DEPENDABLE CAPACITY (GROSS MWE): 815.0 I I
- 7. MAX DEPENDABLE CAPACITY (NET MWE): 790.0 l
8.
IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT,
{
GIVE REASONS:
l
- 9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE): NONE
- 10. REASONS FOR RESTRICTION IF ANY:
I THIS YR TO CUMUL MONTH DATE ATIVE
- 11. HOURS IN REPORTING PERIOD 744.0 5087.0 47088.0 1
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL 366.7 4352.0 32617.3
(
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1647.1
- 14. HOURS GENERATOR ON LINE 358.2 4224.5 30764.1
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 654785.0 7541286.9 61959091.5 l
l '/. GROSS ELECTRICAL ENERGY GENERATED (MWH) 207507.0 2425439.0 20426647.0
- 18. NET ELECTRICIAL ENERGY GENERATED (11WH) 195573.0 2333300.0 19636791.0
- 19. UNIT SERVICE FACTOR 48.1 83.0 65.3
- 20. UNIT AVAILABILITY FACTOR 48.1 83.0 65.3
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 33.3 58.1 52.8 l
- 22. UNIT CAPACITY FACTOR (USING DER NET) 32.0 55.9 50.8 l
- 23. UNIT FORCED OUTAGE RATE 51.9 14.4 21.0
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHb (TYPE, DATE, AND DURATION OF EACH):
i l
25: IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START UP:
8/ 5/82
- 26. UNITS IN TEST STATUS (PRIOR TO COMMERICIAL OPERATION): FORCAST ACHEIVED INITIAL CRITICALITY INITIAL ELECTRICITY l
COMMERICIAL OPERATION l
1.16 - 9
APPENDIX Docket No:
050-325 Unit:
Brunswick No. 1 Date: August 1982 Completed by:
Frances Harrison OPERATIONS
SUMMARY
BRUNSWICK UNIT NO. 1 Brunswick Unit No. 1 operated at 48.1 percent availability factor for the month of July with a 33.3 percent capacity factor. There were two off-line outages this month. They are detailed in Appendix D, the unit shutdowns and power reduction log. The unit operated at reduced power because of core coastdown.
There are 476 BWR and 160 PWR spent fuel bundles in the Brunswick No. I fuel pool.
Investigation on Outage Report #82-074 completed.
It is included in this months report.
h O
DOCKET NO. 050-0M _
UNil'SliUTDOWNS AND POWER REDUCTIONS 4'""*"l
UNIT NAME DATE
^"""S' 1"2 July 1982 COMPLETED BY Frances Harrison REPORT MON 111 TELEPilONE t919 N3/-9321
$g 3
Licensee
,E *r, Cause & Corrective f
No.
Date e-E :)
R EEy Event
=?
c-3 Action to S
jh 5
3d~
Report :
N0
$0 Prevent Recurrence L
u
>d I
82-074 820607 F
37.1 A
3 NA HB VALVEX RX SCRAM - Blown fuse to MSIV Wire on position indication for MSIV was found grounded. Wire was lifted.
Problem will be repaire*d during the, fall 1982. Refueling Outage as TT #1-E-82-2014.
E s
i I
2 3
4 F: Forced Reason:
Method:
Exhibit G. Instructions S: Scheduled A-l'quipment I ailure (Explain)
- 1. Manual for Preparation of Data ll M tintenance of Test 2-Manual Scram.
Entry Sheets for Licenser C-Refochng 3-Automatic Scram.
Event Report (LER) Fde(NUREC.
D Regulatory Restriction 4 Continuations 0161)
E Operator Training & License Examination 5-Load Reductions F Adnsnistrative 6-Other 5
G-Operational Error (Explain)
Exhibit 1. Same Source P7/77)
Il Other (Explain)
F
h O
i DOCKET NO. 050-012s UNIT SliUTDOWNS AND POWER REDUCTIONS ii.ruaswic k 1
[
UNIT N. ole l
DATE Aucust 1982 irances narrison REPORT MONT11 July 1982 COMPLETED IlY TELEPIIONE (919) 457-9521 3
i<
L E
c
.$ E 3
4 5 ~;
Licensee
,E v, g*3 Cause & Corrective No.
Date g
g 3
.3 s U Event gi Action to gO F-f5 5
~5 Report #
in u Prevent Recurrence r
o
.a u
d
=
6 82-089 July 10, 198.
F 24.2 A
3 NA liA TURBINE Turbine trip as a result of deiective tracking rectifier.
Defective rectifier was taken out of service. Presently EllC is being fed.
by alternate until rectifier can be repaired.
J.-
i 1
I 2
3 4
F: Forced Reston:
Method:
Exhibit G. Instructions S: Scheduled A l'quipment Failure (Explain) 1-Manual for Preparation of Data 11 Maintenance of Test 2-Manual Scram.
Entry Sheets for Licensee C. Refueling 3 Automatic Scram.
Event Report (LER) Fde (NUREC.
D Regulatory Restriction 4 Continuations 0161)
E Operator Training & License Examination 5-Load Reductions F-Administrative 6-Other I
G-Operational Error (Explain)
Exhibit I.Same Source (9/77) 11-O:her (Explain)
F
p p
y 1
(
f,J DOCKET NO.
UNITSilUTDOWNS AND POWER REDUCTIONS UNIT NAM E DATE Aucust 1982 COMPLETED BY July 1982 N*>'-9'"
REPORT MONTil TELEPilONE b
t n.
.$ ?
'h h.5; Licensee 5-r, Cause & Corrective o
Action to No.
Date g
3 ij jyJ Event y
Q i
F f5 j5-Report #
mo Prevent Recurrence g
d 82-90' 820711 S
94.6 F
5 NA RC ZZZZZZ END OF CYCLE COASTDOWN.
ALL RODS OUT AND 100% CORE FLOW.
i i
y l
1 I
2 3
4 F: ForecJ R:a n-Method:
Exhibit C Instructions S: Scheduled A l'.pn;iment Failure (Explain) 1 Manual for Preparation of Data Il Maintenance or Test 2-Manual Seram.
Entry Sheets for Licensee C. Refueling 3 Automatic Scram.
Event Report (LER) Fde (NUREG.
D Regulatory Restriction 4 Continuations 0161)
E-Operator Training & Ucense Examination 5-Load Reductions 5
F-Adninistrative 6-Other Exhibit I Same Source G-Operational Errur (Explain) 19/77) li Other (Explain) i
DOCKET NO.
050-0325 UNIT SliUTDOWNS AND POWER REDUCTIONS l
UNIT N AME Brunswick I DATE Aucust 1982 COMPLETED BY Fr'ncoe 9,vrison REPORT MONT1f July 1982 TELEPllONE (919) 457-9521 q
.$ g 3
5 Licensee E r, h,
Cause & Corrective No.
Date g
3g 4
- y U Event gy g3 Action to
$E 35 Report #
in u O
Prevent Recurrence H
ou x
zC 82 92 July 16,1982 F
in B
1 NA XX ZZZZZZ Local Leak Rate Testing progress)
(LLRT outage in progress) t t
II i
~
I 2
3 4
F: Forced Reason:
Method:
Exhibit G. Instructions S: Scheduled A l'quipment Failure (Explain) 1-Manual for Pseparation of Data II. Maintenance or Test 2-Manual Scram.
Entry Sheets for Licensee C. Refueling
- 3. Automatic Scram.
Event Report (LER) File (NUREC.
D. Regulatory Restriction 4 Continuations 0161)
E Operator Training & License Examination 5-Load Reductions F Adnunistrative f.Other 5
G-Operational Error (Explain)
Exhibit I-Same Source 19/77)
Il Other (Explain)
O
1 1
APPENDIX B AVERACE DAILY POWER LEVEL DOCKET NO. 050-0324 UNIT BRUNSWICK UNIT 2 DATE 08/03/82 COMPLETED BY FRANCES HARRISON TELEPHONE 919-457-9521 JULY 82 DAY AVG. DAILY POWER LEVEL DAY AVG. DAILY POWER LEVEL (MWE-NET)
(MWE-NET) 1
-7.
17
-10.
2
-8.
18
-10.
3
-10.
19
-10.
4
-10.
20
-10.
5
-13.
21
-10.
6
-13.
22
-10.
7
-12.
23
-9.
8
-11.
24
-7.
9
-13.
25
-8.
10
-10, 26
-8.
11
-9.
27
-9.
12
-9.
28
-10.
13
-9.
29
-9.
14
-10.
30
-9.
15
-9.
31
-9.
16
-8.
1.16 - 8
OPERATING DATA REPORT l
i DOCKET NO. 050-0324 DATE 08/03/82 COMPLETED BY FRANCES HARRISON TELEPHONE 919-457-9521 OPERATING STATUS
- 1. UNIT NAME: BRUNSWICK UNIT 2 I NOTES I
- 2. REPORTING PERIOD: JULY 82 I
I
- 3. LICENSED THERMAL POWER (MWT): 2436 I
I
- 4. NAMEPLATE RATING (GROSS MWE): 867.0 I
I
- 5. DESIGN ELECTRICAL RATING (NET MWE): 821.0 I
I
- 6. MAX DEPENDABLE CAPACITY (GROSS MWE): 815.0 I I
- 7. MAX DEPENDABLE CAPACITY (NET MWE): 790.0 8.
IF CHANGES OCCUR IN CAPACITY RATINGS (ITEMS 3 THRU 7) SINCE LAST REPORT, GIVE REASONS:
- 9. POWER LEVEL TO WHICH RESTRICTED IF ANY (NET MWE): NONE
- 10. REASONS FOR RESTRICTION IF ANY:
THIS YR TO CUMUL MONTH DATE ATIVE l
- 11. HOURS IN REPORTING PERIOD 744.0 5087.0 59112.0
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL 0.0 2465.2 37632.1 l
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 14. HOURS GENERATOR ON LINE 0.0 2384.6 35153.9 i
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL ENERGY GENERATED (MWH) 0.0 4467965.8 64465503.4 l
- 17. GROSS ELECTRICAL ENERGY GENERATED (MWH) 0.0 1415289.0 21409226.0 l
- 18. NET ELECTRICIAL ENERGY GENERATED (MWH)
-7095.0 1344813.0 20534226.0
- 19. UNIT SERVICE FACTOR 0.0 46.9 59.5
- 20. UNIT AVAILABILITY FACTOR 0.0 46.9 59.5
- 21. UNIT CAPACITY FACTOR (USING MDC NET)
-1.2 33.5 44.0
- 22. UNIT CAPACITY FACTOR (USING DER NET)
-1.2 32.2 42.3
- 23. UNIT FORCED OUTAGE RATE 0.0 17.1 17.1
- 24. SHUTDOWNS SCHEDULED OVER NEXT 6 MONTHS (TYPE, DATER AND DURATION OF EACH):
l l
- 25. IF SHUTDOWN AT END OF REPORT PERIODr ESTIMATED DATE OF START UP:
8/ 5/82 l
- 26. UNITS IN TEST STATUS (PRIOR TO COMMERICIAL OPERATION): FORCAST ACHEIVED INITIAL CRITICALITY INITIAL ELECTRICITY COMMERICIAL OPERATION 1.16 - 9
APPENDIX Docket No: 050-324 Unit:
Brunswick No. 2 Date: August 1982 Completed by: Frances Harrison OPERATIONS SUMARY BRUNSWICK UNIT NO. 2 Brunswick Unit No. 2 was shut down the entire month of July for a refueling outage. Estimated startup date is August 5, 1982.
There are 824 BWR and 144 PWR spent fuel bundles in the Brunswick No. 2 fuel pool.
g n
n v
050-0325 DOCKETNO.
UNIT SliUTDOWNS AND POWER REDUCTIONS Brunswick 11 UNIT N AME DATE Anonst Jos, COMPLETED ilY rr,- ",rrienn REPORT MONT11 Julv 1982
,E (o m m o W
,I l
E c
3?
3 455 Licensec Eg je.
Cause & Corrective Action to
,l No.
Date 5g i
.s y J Event p
g"g H
y, E 5
5g.
Report #
v) U Prevent Recurrence oo e
3, C
I.
744 82-054 Aug. 4, 1982 s
C 4
NA RC FUELXX Refueling outage i
V i
I 2
3 4
F: Forced Reason:
Method:
Exhibit G Instructions S: Scheduled A l'quipment Failure (Explain) 1 Manual for Preparation of Data ll Maintenance of Test 2 Manual Scram.
Entry Sheets for Licensee C Refuchng 3 Automatic Scram.
Event Report (LER) Fde (NUREG.
D Regulatory Restriction 4 Continuations 0161)
E-Operator Training & Ucense Examination 5-Load Reductions 5
F. Administrative 6-Other G-Operational Error (Explain)
Exhibit 1.Same Sourec (9/77)
Il Other (Explain) p