___

a, w

f Lee g

UNITED STATES p,

NUCLEAR REGULATORY COMMISSION j

r, j

wAswiscToN, o. c.aoses

...../

i SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION SUPPORTING THE' THERMAL HYDRAULIC MARGINS FOR EXXON TOPROD FOR PRAIRIE ISLAND NUCLEAR GENERATING PLANT UNIT 1, CYCLE 7 DOCKET NO. 50-282 The Exxon Nuclear Company,(ENC) TOPROD fue.1 assembly was designed for use in two loop Westinghouse reactors having fuel assemblies with a 14 x 14 array of fuel rods. The outside diameter of the fuel rods and the fuel pellet diameter have been reduced by approximately 2% relative to the ENC standard assembly. This change results in an improved water-to-fuel ratio of about 7%.

~

From a themal-hydraulic standpoint the effects on interbundle diversion crossflow of the diff erent fuel pin diameters and increased flow area (3%)

and the consequential effects on DNB must be analyzed. Supplement No.1 (Ref.1) to XN-NF-80-56, " Generic Mechanical, Themal Hydraulic and Neutronic Design for Exxon TOPROD Reload Fuel Assemblies for Pressurized Water Reactors, Thermal Margin Analysis" presents the methodology used by Exxon to assess the thermal-hydraulic impacts of a mixed core containing TOPROD and ENC standard assemblies.

The generic review of this documentation is still being performed. However we have evaluated the impact of this mixed core. arrangement on the Prairie Island Unit No.1 (PI-1) Cycle 7 Re' load, and 'our evaluation is as follows:

The thermal margin analysis results for the PIl Cycle 7 are presented in Table 4.1 of Reference 1 assuming a full core of the TOPROD fuel assemblies. The limiting transient has been detemined to be the two-pump coastdown. With 1025 rated power, the initial DNBR is 2.24 using, the W-3 CHF correlation. The minimum DNBR of 1.85 occurs at 3.35 seconds into the transient.

In order to show that the full-core TOPROD assumption is the most limiting, ENC also-perfomed a sensitivity study of the effect on minimum CNBR of core fuel arrangement. As shown in table 4.2 of reference'1 fcr the same transient, a full core of the. standard ENC fuel' assemblies woilld result in minimum DNBR of 1.92, whereas, a mixed core of 1/3 standard fuel and 2/3 TOPROD would result in minimum DNBR of 1.86 and 1.88, respectively, for standard fuel and TOPROD fuel limiting cases.- Therefore, the full core TOPROD assumptions results in the most limiting minimum DNBR compared to the mixed core or full core of standard assemblies.

The themal margin analysis is done in two steps.

First a core wide assembly flow distribution is performed to establish minimum flow to the limiting i

assembly. A subcharinel calculation is then done to determine the minimum i

DNBR for the limiting subchannel in the hot assembly. The core-wide analysis 1

is performed with an open lattice model. The interbundle diversion crossflow and turbulent mixing are considered using small values of crossflow resistance and turbulent mixing. A mass velocity flow factor is obtained for the limiting i

DTIG M f> 031CI " L Cortified By

?

R-V 8208040646 820722 PDR ADOCK 05000282 P

PDR

t 1

f 2-3, hot assembly by averaging the axial flow distribution in the assembly. This mass velocity flow factor is then used to perform the limiting assembly hot.

channel minimum DNBR analysis. In the hot channel analysis.the limiting assembly

~

is assumed closed to the neighboring assemblies with.the assembly mass velocity equal to the product of the flow factor and core average mass velocity.

ENC contends that th3s-simolified approach is conservative.

The staff is still reviewing the uncertainty due to the simplified closed hot assembly approach. The effect of crossflow resistance on interbundle diversion crossflow in the core wide analysis, and the validity of input parameters and assumptions implicit to the analytical technique are being evaluated with respect-to the overall effect of mixed core on minimum DNBR calculation. However, our review has progressed sufficiently to conclude that the full core TOPROD calculation is a reasonable approximation if not a conservative analysis of the limiti.ng assembly in the mixed core.

Using the methodology described in XN-NF-75-32, Supplement 1 (Ref. 2), ENC' also presented, in Table A-4 of reference 1, a rod bow penalty of 13.7% based on a maximum fuel burnup of 42500 MWD /MTU Since this methodology ~~~

is still under review by the staff, we have calculated the amount of gap closure, for the TOPROD assembly, using(the methods described in our interim safety evaluation report on rod bowing Ref. 3). We have calculated the amount of gap closure to be 62.1% for a burnup of 15000 MWD /MTU which is the maximum burnup for the limiting TOPROD assembly by the end of Cycle 7.

The resultant DNBR penalty is 21.14. With this rod bow penalty, the MDNBR for PIl TOPROD will be reduced from 1.85 to 1.46 for the limiting two pump coastdown transient compared to the 1.30 MDN5R limit for W-3.

The staff concludes that the available thermal margin of 12% is large enough to account for the interbundle crossflow uncertainties. We therefore, conclude that the operation of PIl Cycle 7 is acceptable. However, we shall continua our generic review on the effect of mixed core arrangement and interbundle crossflow on DNBR, and the rod bow methodology described in reference 2.

Our findings will be addressed separately in a generic evaluatio,n report and will be applicable to Prairie Island.

References:

XN-NF-80-56, Supplement 1, " Generic Mechanical, Thermal Hydraulic and Neutronic 1.

Design for Exxon Nuclear Neutronic Design for Exxon Nuclear TOPROD Reload Fuel Assemblies for Pressurized Water Ther-=1 Margin Analysis", October 1981 2.

XN-NF-75-32, Supplementi, " Computational Procedure for Evaluating Fuel Rod Bowing", July.1981 3.

Memo from D. R. Ross to D. B. Vassallo, " Revised Interim Safety Evaluation Report on the Effects of Fuel Rod Bowing on Thermal Margin Calculations for Light Water Reactors", dated February 16, 1977 October 20, 1981

  • ~ ~ '