ML20059N034

From kanterella
Jump to navigation Jump to search
Forwards Nonproprietary Amend 14 to Advanced BWR SSAR
ML20059N034
Person / Time
Site: 05000605
Issue date: 10/02/1990
From: Robare D
GENERAL ELECTRIC CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20059N035 List:
References
126-90, EEN-9055, NUDOCS 9010090072
Download: ML20059N034 (2)


Text

__

-_.~_____ _._ __._

V GE Nuclest Energy l

Gewo' temt Compey 175 Cuver A.we. San.nst CA 95125 L

October 2,1990 MFN No.126-90 Docket No. STN 50 605 EEN 9055 Document Control Desk l

U.S. Nuclear Regulatory Commission Washington, D.C. 20555 i

Attention:

Charles L. Miller, Director Standardization and Non Power Reactor Project Directorate

Subject:

Submittal of Amendment 14, Non Proprietary Information, to GE's ABWR SSAR

Reference:

Submittal of Amendment 14, Proprietary Information, to OE's ABWR SSAR, MFN No.127 90, dated October 2,1990

Dear Mr. Miller:

Enclosed are thirty four copies of selected sections of Chapter 1, Introduction and General Description of Plant, Chapter 3, Design of Structures, Components, Equipment, and Systems, j

Chapter 4,~ Reactor. Chapter 5, Reactor Coolant System and Connected Systems, Chapter 6, i

Engineered Safety Features, Chapter 7, frutrumentation and Control Systems, Chapter 9, Aunliary i

Systems, Chapter 10, Steam and Power Conversion System, Chapter 11, Radioactive Waste Management, Chapter 12, Radiation Protection, Chapter 13, Conduct of Operations, Chapter 15, Accident Analysis, Chapter 18, Human Factors Engineering, Chapter 19, Response to Severe Accident Po! icy Statement, Chapter 20, Question and Response Guide, of the Standard Safety s

Analysis Report (SSAR) for the Advanced Boiling Water Reactor (ABWR).

This submittalincludes the major revision or addition of the following information: Inservice testing of safety related pumps and valves to Chapter 3; fire hazard analyses for turbine building, service building. radwaste budding and the plant yard to Chapter 9; and PRA based maintenance and reliability to Chapter 19.

In addition, there are other changes to various sections of the SSAR which are identified, along L

with the above changes, on the page change instruction sheet.

C, 9010090072 901002 1

ADOCK'o5oog5 DR 1

w.

\\

[h

..s I

I Document Control Desk Docket No. STN 50-605 U.S. Nuclear Regulatory Commission MFN No.126 90 October 1,1990 Page 2 Revised pages of the Page Status listing are included, please replace the corresponding pages with the enclosed pages.

This submittal also includes a set of chapter tabs, please replace and add these tabs as required.

Please note that all or parts of the following sections contain information that is designated as General Electric Company proprietary information: 1.2, 31, 7.3, 7.6, 9.5, 9A,11.2,11.3, ISB,18A, 18B,18D,19.1,19.3,19B,19K and 20.3. This information is being submitted under separate cover.

Sincerely, N

O D.J. Robare, Acting Manager Regulatory and Analysis Services cc:

D. R. Wilkins (GE)

T.E. Murley (NRC)

D.M.Crutchfield (NRC)

DJ. McGoff (DOE)

FJ. Miraglia, Jr. (NRC)

D.C. Scaletti (NRC)

K.E. Stahlkoph (EPRI)

F.A. Ross (DOE) l I