6 ADVANCED NUCLEAR FUELS CORPORATION 2101 e4OhN RAhD5 h0AD. PO BOM iJJ ktCrhAhD. nA 993 9 0130 f Lo[L EtJGINEEHil.G &
(509) 375 0100 TELEX 152870 1ECytytCAg 3,L pqpcgg, September 26, 1988 RAC:059:88 t
Mr. M. W. Hodges, Chief keactor Systems 8 ranch Division of Engineering and Systems Technology Office of flutlear Reactor Regulation U. S. fluclear Regulatory Commission Washington, D. C.
20555
Dear Mr. Hodges:
Subject:
Fuel Performance Annual Renort Ref.:
Letter, M.W.
Hodges (f4RC) to R. A. Copeland (ANF), dated August 4, 1988 The Ottachment provides a summary of Advanced fluclear Fuei's fuel performance through December 1987, as requested in the reference letter.
Please contact me directly if there are any questions.
i Sincerely, O
R. A. Copeland, Manager Reload Licensing gf Attachment Dr. S. L. Wu (USNRC)
?
b i
9402030211 911025 PDR ADOCK 05000605 A
PDR _
t 9
Advanced Nuclear Fuels Corocration ( ANF) Fuel Performance Through 1987, a total of 12,058 ANF fuel assemblies comprising 1,531,649 fuel rods had been irradiated. Of these, 6852 were BWR fuel assemblies and 5,206 were PWR's.
Table 1
summarizes the assembly distribution, fuel rod performance, and gadolinia fuel experience of ANF fuel in both BWR's and PWR's as of December 31, 1987.
Figure 1 highlights the exposure distribution of ANF fuel rods and assemblies as of that time.
Maximum exposure levels in both PWRs and BWRs were reached by fuel in two high burnup programs.
One PWR assembly reached a burnup of 49.98 GWd/MTU after 4 cycles of irradiation at Tihange-1 in Belgium. A peak burnup for BWR fuel of 41.1 GWd/MTV was achieved by a group of Extended Burnup Demonstration fuel rods irradiated at-Big Rock Point.
~
~
L Through 1987, ANF fuel integrity based on failures from fuel-related or unknown causes remained at better than 99.995%.
T i
-O Table 1 Summary of Advanced Nuclear Fuels Corporation Fuel Assembly Distribution, fuel Rod Performance, and Gadolinia fuel Experience, As of December 31,-1987 i
s A.
FUEL ASSEMBLIES Reactor In Core as of Discharged as Tyne Dec. 31. 1987 of Dec. 31. 1987 Total i
BWR 4,927 1,925 6,852 PWR 2.298 2.908 5.206 Total 7,225 4,833 12,058 B.
FUEL RODS In Core Discharoed Peak Assy.
Peak Assy.
Total Reactor Number Burnup Number Burnup Number Failure Type of Rods mwd /MTV of Rods mwd /MTU of Rods Rate. % (al BWR 330,023 37,640 116,912 41,100 446,935-0.011 PWR 493.855 43.000 590.859 49.980 1.084.714 0.003 Total 823,878 707,771 1,531,649 0.005 C.
GAD 0LINIA RODS Reactor Number of Gadolinia Type Rods Irradiated BWR 32,149 PWR
__4 183.
Total 37,037 (a) Failures not directly attributable to external causes (e.g., plant-related causes such as baffle jetting, fretting from the presence of foreign objects or other off-normal core conditions).
9 t-b
'd e
~ p 5 0 a 2
.o m
un 3
3 L
w n n
..o a
W H
O O
0 0
E E
v e
"**h s"
"S
~~0 00 09 a,
U
-8 e2 U C C U a
U n
e 45
}
ai.
m a V Q 1..
.b
=
o a
s
\\-
o ArO Rh\\W :,
HM :i n
225
~
W
&..%3.[
21 g
e,R ER 5 R' 8R 8R C>
E 8
Q a.
n S
g g
g
~
E3n8n3SSY *13M 031Y10VEBI J0 k38nnN gocy g3 y g32yjgygg;jo g3gnny