ML20059J232

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Accepting LAR 92-14,submitted Via for TS Changes to Allow Independent Fixed Incore Detector Sys at Facility to Be Used for Periodic in-core Power Distribution TS SRs
ML20059J232
Person / Time
Site: Seabrook 
Issue date: 11/05/1993
From: Rosalyn Jones
Office of Nuclear Reactor Regulation
To: Stolz J
Office of Nuclear Reactor Regulation
Shared Package
ML20059J234 List:
References
TAC-M85020, NUDOCS 9311120104
Download: ML20059J232 (1)


Text

_.

November 5, 1993 MEMORANDUM FOR:

John F. Stolz, Director (14-C-7)

Project Directorate I-4

^

Division of Reactor Projects I/II t

FROM:

Robert C. Jones, Chief Reactor Systems Branch-l Division of Systems Safety and Analysis

SUBJECT:

TECHNICAL SPECIFICATION CHANGES TO ALLOW THE USE OF A FIXED INCORE DETECTOR SYSTEM AT SEABROOK STATION (TAC NO. M85020)

Plant Name:

Seabrook Nuclear Power Station Utility:

North Atlantic Energy Service Corporation TAC No(s).:

M85020 Docket No(s).:

50-443 Operating License:

NPF-86 Project Directorate:

Project Directorate I-4 Project Manager:

A. DeAgazio 1

Review Branch:

SRXB/DSSA Review Status:

Complete By letter of November 25, 1992, North Atlantic Energy Service Corporation-l (NAESC) submitted License Amendment Request 92-14 for Technical Specification (TS) changes to allow the independent Fixed Incore Detector System (FIDS) at Seabrook Station to be used for the periodic in-core power distribution TS surveillance requirements, as an alternate to the standard Movable Incore Detector System.

We have reviewed the submittal and find the NAESC request regarding TS changes l

required for use of the Seabrook FIDS to be acceptable, as discussed in the safety evaluation report provided as Enclosure 1. _ The SER does require some limited continued use of the movable detector system. This condition was discussed with the licensee in a telecon with Mr. DeAgazio and Dr. Schwenk and 1

is acceptable to NAESC. Our SALP evaluation is provided in Enclosure 2. -This completes our effort on TAC No. M85020.

nic o.: w _r;,.

Q9 t ;4 C *.~ m Robert C. Jones, Chief Reactor Systems Branch Division of Systems Safety and Analysis

Enclosure:

DISTRIBUTION-As stated

' Central e files /PDRt SRXB R/F cc:

A. DeAgazio (14C7)

RJones A. Thadani LPhillips G. Schwenk EKendrick L. Lois EKendrick R/F

Contact:

E. Kendrick, DSSA/SRXB; 504-2891

  • SEE PREVIOUS CONCURRENCE PACE SRXB:DSSA*-

SRXB:DSSA*

SRXB:DSSA*

DSSA EKENDRICK:jh GSCHWENK LPHILLIPS S-10/13/93 10/27/93 10/28/93 11/3 /93 DOCUMENT NAME: G:\\SEABROOK' y

i 9311120104'931105

$9

)

PDR ADOCK 05000443 j. l P

PDR tb

.