Surveillance Pace No.
l l
3.7 CONTAINMENT SYSTEMS 4.7 152 A.
152 B.
Standby Gas Treatment System and B
158 Control Room High Efficiency Air Filtration System C.
159 3.8 RADI0 ACTIVE EFFLUENTS 4.8 177 A.
Liquid Effluents Concentration A
177 B.
Radioactive Liquid Effluent B
177 Instrumentation C.
Liquid Radwaste Treatment C
178 D.
Gaseous Effluents Dose Rate D
179 E.
Radioactive Gaseous Effluent E
180 Instrumentation F.
Gaseous Effluent Treatment F
181 G.
182 H.
Mechanical Vacuum Pump H
183 3.9 AUXILIARY ELECTRICAL SYSTEM 4.9 194 A.
Auxiliary Electrical Equipment A
194 B.
Operation with Inoperable Equipment 196 3.10 CORE ALTERATIONS 4.10 202 A.
Refueling Interlocks A
202 B.
Core Monitoring B
202 C.
Sr Fuel Pool Water Level C
203 l
D.
Muit spie Control Rod Removal D
203 3.11 REACTOR FUEL ASSEMBLY 4.11 205a A.
Average Planar Linear Heat A
205a
)
Generation Rate (APLHGR)
B.
Linear Heat Generation Rate (LHGR)
B 205b C.
Minimum Critical Power Ratio (MCPR)
C 205c D.
Power / Flow Relationship D
205d l
3.12 FIRE PROTECTION - ALTERNATE SHUTDOWN 4.12 206 PANELS 3.13 INSERVICE CODE TESTING 4.13 206C l
A.
Inservice Code Testing of A
206C l
Pumps and Valves 9311120066 931104 l
PDR ADOCK 05000293 l
P PDR j
Revision 168 Amendment No.
15r-27; 355-45; 84r-89;-113;-114 -133 143 149 ii 5
7 f
LIMITING CONDITIONS FOR OPERATION SURVEILLANCE RE0UTREMENTS l
3.13 INSERVICE CODE TESTING 4.13 INSERVICE CODE TESTING t
APPLICABILITY:
APPLICABILITY:
Applies to ASME Code Class 1, 2 and 3 Applies to the periodic testing or equivalent pumps and valves.
requirements of ASME Code Class 1, 2 l
and 3 or equivalent pumps and valves.
l
)
OBJECTIVE:
OBJECTIVE:
l To assess the operational readiness j
To assure the operational readiness of of safety and safety-related pumps j
ASME Code Class 1, 2, and 3 (Safety and valves by performance of Related) or equivaler.t (important to inservice tests.
i safety) pumps and valves.
SPECIFICATION:
SPECIFICATION:
A.
INSERVICE CODE TESTING OF PUMPS A.
INSERVICE CODE TESTING OF PUMPS l
AND VALVES AND VALVES 1.
Based on the Facility Commercial Operation Date, Inservice Code 1.
Inservice Code Testing Testing of safety and safety-activities shall be performed related pumps and valves shall in accordance with Section XI be performed in accordance with of the ASME Boiler and Pressure i
the ASME Boiler and Pressure Vessel Code and applicable l
Vessel Code,Section XI " Rules Addenda as required by for Inservice Testing of Nuclear 100FR50.55a(f), with the Power Plant Components" exemptions and alternate Subsections IWP and IWV as testing that have been approved required by 10CFR50.55a(f),
by the NRC pursuant to except where specific relief has 10CFR50.55a(f)(6)(i). These been granted by the NRC pursuant exemptions and alternate l
4 to 10CFR50.55a(f)(6)(i).
testing are included in the i
PNPS Inservice Testing Program.
l f
2.
Test Frequencies for Code Terminology when performing Inservice Test activities.
Code Terminology Freouencies Weekly 7 Days Monthly 31 Days Quarterly or 3 Mths 92 Days Semiannually /6 Mths 184 Days 9 Months 276 Days j
Yearly / Annually 366 Days j
Biannual /2 Yrs 732 Days 3.
The provisions in Definitions (1.0) for REFUELING INTERVAL,
{
SURVEILLANCE FREQUENCY, and SURVEILLANCE INTERVAL are applicable to Code testing and d
Revision 168 Amendment No. 149 206C
l e
LIMITING CONDITIONS FOR OPERATION SURVEILLANCE RE0VIREMENTS 3.13 INSERVICE CODE TESTING 4.13 INSERVICE CODE TESTING to the above frequencies for performing Code testing activities.
4.
Performance of Code testing shall be in addition to other specified Surveillance Requirements.
]
5.
Nothing in the ASME Boiler and i
Pressure Vessel Code shall supersede the requirements of Technical Specifications.
l i
Revision 168 Amendment No. 149 2060
f BASES:
3.13 and 4.13 Inservice Code Testina The Limiting Conditions for Operation establishes the requirement that inservice testing of ASME Code Class 1, 2, and 3 pumps and valves shall be performed in accordance with the periodically updated edition of Section XI of the ASME Boiler and Pressure Vessel Code and Addenda as required by 10CFR50, Section 50.55a(g). These requirements apply except when relief has been requested pursuant to 10CFR50.55a(g)(6)(i) and granted by the NRC. The NRC may grant relief pursuant to 10CFR50.55a(a)(3)(i), 10CFR50.55a(a)(3)(ii) or 10CFR50.55a(a)(6)(i).
The detailed procedures for testing of pumps and valves are documented in the PNPS Inservice Testing Program.
This specification includes a clarification of the frequencies for performing the testing act'vities required by Section XI of the ASME Boiler and Pressure Vessel Code and applicable Addenda.
This clarification is provided to ensure consistency in Surveillance Frequencies throughout the Technical Specifications and to remove any ambiguities relative to the frequencies for performing the required inservice testing activities.
Under the terms of this Specification, the more restrictive requirements of the Technical Specifications take precedence over the ASME Boiler and Pressure Vessel Code and applicable Addenda.
For example:
Technical Specifications require components to be declared operable prior to entry into an operational mode. The ASME B&PV Code provision which allows pumps and valves to be tested up to one week after return to normal operation is superseded (and not allowed) by the more restrictive requirements of Technical Specifications.
The allowance for a valve to be incapable of performing its specified function for up to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> before being declared inoperable is superseded (and not allowed) by the more restrictive Technical Specification definition of operability which does not allow a grace period.
Revision 168 Amendment 149 206E l