ML20059B916

From kanterella
Jump to navigation Jump to search
Corrected Pages 3/4 3-4 & 3/4 3-37 of TS to Amends 67 & 46 to Licenses NPF-68 & NPF-81,respectively.Pages Revised to Correct Admninistrative Errors
ML20059B916
Person / Time
Site: Vogtle  Southern Nuclear icon.png
Issue date: 10/19/1993
From:
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20059B920 List:
References
NPF-68-A-067, NPF-81-A-046 NUDOCS 9310290146
Download: ML20059B916 (2)


Text

,.

=.

TABLE 3.3-1 (Continued)

E 5

REACTOR TRIP SYSTEM INSTRUMENTATION 8S

$o E MINIMUM g g c-TOTAL NO.

CHANNELS CHANNELS APPLICABLE h FUNCTIONAL UNIT OF CHANNELS TO TRIP OPERABLE MODES ACTION 7 0-o4 M gS -

b.

Two Loops (Above P-7 and 3/ loop 2/ loop in 2/ loop l'

6

,co a below P-8)

~

two oper-each oper-gaa N ating loops ating loop S

(l00P1 LOOP 2 LOOP 3 LOOP 4 FI-0414 FI-0424 FI-0434 FI-0444 FI-0415

'FI-0425 FI-0435 FI-0445 FI-0416 FI-0426 FI-0436 FI-0446) 13.

SteamGeneratopWater 4/stm. gen.

2/stm. gen.

3/stm. gen.

1, 2 6

I Level--Low-Low in any oper-each oper-ating stm.

ating stm.

gen.

gen.

(LOOP 1 LOOP 2 LOOP 3 LOOP 4 LI-0517 LI-0527 LI-0537 LI-0547 LI-0518 LI-0528 LI-0538 LI-0548 Y

LI-0519 LI-0529 LI-0539 LI-0549

^

LI-0551 LI-0552 LI-0553 LI-0554) 14.

Undervoltage--Reactor Coolant Pumps 4-2/ bus 2

3 l'

9 j

i S5 15.

Underfrequency--Reactor Coolant hh Pumps 4-2/ bus 2'

3 l'

9 l

mo 55 16.

Turbine Trip gg a.

Low Fluid Oil Pressure 3

2 2

l' 6

(PT-6161, PT-6162, PT-6163) gg b.

Turbine Stop Valve Closure 4

4 1

l' 12 EE 17.

Safety Injection Input hh from ESF 2

1 2

1, 2 7

l

'See Specification 3.3.3.6

s.

s TABLE 4.3-2 (Continued)

<8 ENGINEERED SAFETY FEATURES ACTUATION SYSTEM INSTRUMENTATION

[

SURVEILLANCE REQUIREMENTS E

TRIP Z

ANALOG ACTUATING MODES CHANNEL DEVICE MASTER SLAVE FOR WHICH CHANNEL CHANNEL OPERATIONAL OPERATIONAL ACTUATION RELAY RELAY SURVEILLANCE

[FUNCTIONALUNIT CHECK CALIBRATION TEST TEST LOGIC TEST TEST TEST.

IS REQUIRED

1. (Continued)
e. Steam Line S

R Q

N.A.

N.A.

N.A.

N.A.

l##, 2##, 3## l Pressure-Low *

(LOOP 1 LOOP 2 LOOP 3 LOOP 4 PI-0514A,B&C PI-0524A&B PI-0534A&B PI-0544A,B&C PI-0515A PI-0525A PI-0535A PI-0545A PI-0516A PI-0526A PI-0536A PI-0546A)

2. Containment Spray g
a. Manual Initiation N.A.

N.A.

N.A.

R N.A.

N.A.

N.A.

1, 2, 3, 4

[

b. Automatic Actuation N.A.

N.A.

N.A.

N.A.

M(1)

M(1)

Q 1, 2, 3, 4 a,

Logic and Actuation Relays N

c. Containment Pressure-S R

Q N.A.

N.A.

N.A.

N.A.

1",2",3",4" o Pug >

High-3** (PI-0934, PI-0935, PI-0936, yy PI-0937) a~

R E 3. Containment Isolation zu

??

a. Phase "A" Isolation um
1) Manual Initiation N.A.

N.A.

N.A.

R N.A.

N.A.

N.A.

1, 2, 3, 4 EE

2) Automatic Actuation N.A.

N.A.

N.A.

N.A.

M(1)

M(1)

Q 1, 2, 3, 4

3. 3.

Logic and Actuation Relays SC

    • See Specification 4.3.3.6.

.,