P October 21, 1993 ar.
Docket No. 50-331 DISTRIBUTION Docket File JHannon OPA NRC & Local PDRs MRushbrook Mr. Lee Liu PDIII-3 Reading RPulsifer Chairman of the Board and TMurley/FMiraglia 0GC Chief Executive Officer JPartlow EJordan Iowa Electric Light and Power Company ERossi GHill(2)
P. O. Box 351 JLieberman ACRS(10)
Cedar Rapids, Iowa 52406 JRoe ED0 JZwolinski OC/LFDCB
Dear Mr. Liu:
PD3-3 Gray File Region III, DRP
SUBJECT:
DUANE ARNOLD ENERGY CENTER - NON-CODE REPAIR OF THE "D" OUTBOARD l
MAIN STEAM ISOLATION VALVE (TAC NO. M87666)
By letter dated September 18, 1993, you submitted a request for relief from l
the American Society of Mechanical Engineers (ASME) Code,Section XI requirements regarding repair of the "D" outboard main steam isolation valve (MSIV). The NRC staff responded by letter dated September 24, 1993, granting the requested relief provided a radiographic inspection of the MSIV body is accomplished after the next two scheduled refueling outages.
A question regarding the meaning of "after the next two scheduled refueling outages" was raised. The staff's intent of this statement is to assure that a radiographic inspection of the repaired areas is performed on the MSIV body during each of the next two refueling outages.
Sincerely, Allen G. Hansen/for John N Hannon, Director Project Directorate III-3 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation cc:
See next page E
9310280030 931021 PDR ADOCK 05000331 h G
PDR y;
LA PM:P E
OGC PD:PD3-3
- MRusbrbsk R%1
/bj
- MYoung JHanno I e [ _
d'
\\
10/4/93 0 % Q 10/L 93 10/8/93
/o f/ /9 1
- See previbus concurrence 0FFICIAL RECORD DOCUMENT NAME:
g:\\duanearn\\dua87666.ltr 500 fliY b
=
20000,~
<y t,9' u
~.
~
(.-
>R Rf C 6
UNITED STATES 4
j j
NUCLEAR REGULATORY COMMISSION i
WASHINGTON D.C. 20lili6-0001 i
\\.,,,.*
October 21, 1993
{
Docket No. 50-331 i
Mr. Lee Liu Chairman of the Board and Chief Executive Officer Iowa Electric Light and Power Company P. O. Box 351 Cedar Rapids, Iowa 52406
Dear Mr. Liu:
SUBJECT:
DUANE ARNOLD ENERGY CENTER - NON-CODE REPAIR OF THE "D" OUTBOARD MAIN STEAM ISOLATION VALVE (TAC NO. M87666)
By letter dated September 18, 1993, you submitted a request for relief from the American Society of Mechanical Engineers (ASME) Code,Section XI requirements regarding repair of the "D" outboard main steam isolation valve (MSIV). The NRC staff responded by letter dated' September 24, 1993, granting the requested relief provided a radiographic inspection of the MSIV body is accomplished after the next two scheduled refueling outages.
'l A question regarding the meaning of "after the next two scheduled refueling outages" was raised. The staff's intent of this statement is to assure'that a radiographic inspection of the repaired areas is performed on the MSIV-body during each of the next two refueling outages.
Sincerely, Y
w John N Hannon, Director Project Directorate III-3 Division of Reactor Projects - III/IV/V Office of Nuclear Reactor Regulation l
cc:
1 See next page
m s
13 Mr. Lee Liu Iowa Electric Light and Power Company Duane Arnold Energy Center cc:
Jack Newman, Esquire Kathleen H. Shea, Esquire Newman and Holtzinger 1615 L Street, N.W.
Washington, D.C.
20036 Chairmar., Linn County Board of Supervisors Cedar Rapids, Iowa 52406 lowa Electric Light and Power Company ATTN:
David L. Wilson Plant Superintendent, Nuclear 3277 DAEC Road Palo, Iowa 52324 Mr. John F. Franz, Jr.
Vice President, Nuclear Duane Arnold Energy Center 3277 DAEC Road Palo, Iowa 52324 Mr. Keith Young Manager, Nuclear Licensing Duane Arnold Energy Center 3277 DAEC Road Palo, Iowa 52324 U.S. Nuclear Regulatory Commission Resident Inspector's Office Rural Route #1 Palo, Iowa 52324 Regional Administrator, Region III U.S. Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137 Mr. Stephen N. Brown Utilities Division Iowa Department of Commerce Lucas Office Building, 5th Floor Des Moines, Iowa 50319