ML20058L166

From kanterella
Jump to navigation Jump to search
Ro:On 740316 & 17,while Performing Local Leak Rate Tests on Primary Containment Isolation Valves,Listed Valves Found to Have Leakage in Excess of Tech Spec Limits.Investigation Will Be Conducted
ML20058L166
Person / Time
Site: Monticello 
Issue date: 03/18/1974
From: Larson C
NORTHERN STATES POWER CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 9105080338
Download: ML20058L166 (1)


Text

. _...

,5.QM

' } ACW,.lg a 6

p f

f u

I

(

L]

5

~ ~ ~ ~

Q[ C NE! b!IS M

~

NORTHERN STATES P

ER C0MPANT r-

., iknticello, Minnesot

  • 55352 t
  • r.

i,.

-Y.

March 18, 1974 g

, e_,f e ** e

/(p

t. )

q

/

5//

/

g

-)!

Mr. J. G.

er, Regional Director

(.

Directorate o Regulstery Operations r

MAR 201974

  • 10 r

Region III j

e thited States Atomic Energy Conmission

~ h 799 Roosevelt. Road en

?,'fn

  1. /

l' Glen Ellyn, Illinois 61073

'f f

Dear Mr. Keppler:

i.,

~

FDhTICELID ?IJCLEAR GENERATIlE PIANI' j

Docket IJo, 50-263 License Ib. DPR-22

?

I

. r-=

=.

Do March 16 and 17,1974, while perfoming local leak rate tests en pritary NN ~ # - I containment isolation valves, the following valves were founi to have leakage in excess of that allowed by the Technical Specifications:

O i

Valve No.

V f g" c 4 -

Description "N[2Y w wn.

w.:e 16IV 2-SGA Inboard Main Steam Isolatica Valve

..; 45=-m 4

AD 10-46A IPCI "A" Ioop Check Valve it.fh =m.

na W ycy 3 !

b 10 2373 Inboard Main Steam Line Drain Isolayan Valve

]

f p

An investigatica intc the cause of the excess leakages will be cen+rted M n-prior to returning to pmer operation.

U-

%s, -

k Yours very tmly, C. E. lArsen m_

Plant Manager

.(s.

i W=M l

.f..

~a,~ _ z,.

i J F O' Leary, Directorate of Lir.ensing C

cc:

G Charreff

,9:NO:

\\p% 'tW9 1

Minnesota Pollution Centrol Agency

\\

gn

,*p' Attn: E A Pry:.ina

, File

&sfV

)

. ~

s v

Copies sent by telecopier to K@pler and O' Leary 9105080338 740318 CF ADOCK 05000263 C

CF

.' ' ' n

~:dU