ML20058G228

From kanterella
Jump to navigation Jump to search
Second Interim Deficiency Rept Re Incorrect Insp Code on Hanger Drawings by Itt Grinnell.Initially Reported on 820301.Weld Documentation & Hanger Drawings for ASME Section III Class 2 Under Review.Also Reported Per Part 21
ML20058G228
Person / Time
Site: Bellefonte  
Issue date: 07/26/1982
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-82 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8208030238
Download: ML20058G228 (2)


Text

t TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 37401 400 Chestnut Street Tower II v>

~f

~3 July 26, 1982 M

BLRD-50-438/82-24 e

'A BLRD-50-439/82-21 T 34 c:.;,

y T

Td U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James P. O'Reilly, Regional Administrator i

~~

101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - INCORRECT INSPECTION CODE ON HANGER DRAWINGS BY ITT GRINNELL - BLRD-50-438/82-24, BLRD-50-439/82 SECOND INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector Don Quick,on March 1, 1982 in accordance with 10 CFR 50.55(e) as NCR 1748.

This was followed by our first interim report dated March 30, 1982.

Enclosed is our second interim report. We expect to submit our next report by October 27, 1982. We consider 10 CFR Part 21 applicable to this deficiency.

If you have any questions concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY D5%

L. M. Mills, Manager Nuclear Licensing Enclosure oc:

Mr. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555

bg @ C G P T j' 8208030238 820726

- ~

PDR ADOCK 05000438 s

PDR An Ecual Opportunity Employer

S A

ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 INCORRECT INSPECTION CODE ON HANGER DRAWINGS BY ITT GRINNELL NCR 1748 BLRD-50-438/82-24, BLRD-50-439/82-21 10 CFR 50.55(e)

SECOND INTERIM REPORT Description of Deficiency During a review of weld documentation and pipe hanger drawings, plate and shell welds on safety-related hangers were discovered which did not receive a dye-penetrant inspection as required in ASME Section III, Class 2, Subsection NF.

Two causes for this deficiency were determined.

(1) Inspection requirements were overlooked by TVA personnel reviewing the hunger drawings to generate the automated process control (APC) weld cards used in construction of the support.

(2) TVA's hanger vendor (ITT Grinnell, Providence, Rhode Island) specified some ASME Section III, Class 2, welded joints to the wrong inspection code paragraphs (NF-5231, etc.).

The vendor portion of this NCR is not applicable to other plants since ITT Grinnell has a hanger contract only with Bellefonte. The improper inspection of the hanger drawings for weld inspection requirements may be of generic nature; and therefore, the NCR will be directed to other plants for consideration.

Interim Progress TVA is in the process of reviewing ~ all weld documentation and hanger drawings for ASME Section III, Class 2, supports to determine if the proper weld inspection was performed.

ITT Grinnell is reviewing all ASME Section III, Class 2, supports for adequacy of inspection code specified.

o

__