i t

t ATTACHMENT CONSUMERS POWER COMPANY BIG ROCK POINT PLANT DOCKET 50-155 i

1993 INSERVICE INSPECTION REPORT i

Submitted November 29, 1993 22 Pages

]

i 9312070217 931129

.4 PDR ADOCK 06000155 1

Q PDR u

1993 INSERVICE INSPECTION 3-1 BIG ROCK POINT PLANT F

Inservice Inspection No. 3-1 was conducted during the period of June 26, 1993 through September 5, 1993 in accordant? I ch Section 9.0 of the Big Rock Point i

Technical Specifications, except as specified by Consumers Power Company letter dated January 22, 1993, which updated the applicable ASME Boiler and Pressure Vessel Code,Section XI to the 1986 Edition.

Areas examined during this inspection included various components of the portions of the nuclear steam system and portions of various support systems piping as itemized in the attached Table 2 - Inservice Inspection No. 3-1 Examination Table.

The examinations were performed using Radiographic (RT) Ultrasonic (UT),

l Liquid Penetrant (PT) and Visual (VT) techniques. The various examinations were conducted in accordance with Consumers Power Company Engineering and Technical Services Department (E&TS), Southwest Research Institute (SWRI) and EBASCO Services Inc using approved procedures.

Examinations were performed by personnel qualified in the NDT process utilized in accordance with the requirements of Section XI IWA-2300, 1986 ASME Boiler and Pressure Vessel e

Code.

Instances of reportable indications are itemized in the attached Table 1 - Resolution of Reportable Indications.

The following is a list of repairs / replacements which have been performed from May 1992 through the end of the 1993 refueling outage for which HIS-2 forms are attached:

Replacement of the feedwater regulating valve i

Replacement of the reactor head vent line Replacement of RDS Target Rock valve bolting Replacement of reactor head vent line flange Repair of steam drum level sensing line weld Repair of RDS branch connection socket weld During the 1993 ISI inspections augmented IGSCC inspections were performed in accordance with the IGSCC Inspection Program approved by the NRC in a letter dated October 19, 1992. The results of these inspections were acceptable.

It should be noted that weld 24-MRS-121-01 (this weld contains an IGSCC like indication) was re-examined and the indication noted in previous exams has not i

changed in size.

All records detailing procedures, personnel and equipment certifications, examination data, and disposition of reportable indications are on file at the Big Rock Point Plant and also in General Office,1945 West Parnall Road, Jackson, Michigan 49201.

h l

FORM NIS 1 OWNER'S REPORT FOR INSERVICE INSPECTIONS l

As required by the Pr:vitns of the ASME Code Rules' l

l i

1. Owner Constaners Power Conpany, 212 W. Midtigan Ave., Jackson, MI 49201 (Name and Address of Owner)
2. Plant Big Rock Point Power Plant,10269 US 31 North, Ourlevoix, MI 49720 l

(Name and Address of Plant) l

3. Plant Unit 1
4. Owner Certificate of Authorization (if required)

N/A

5. Commercial Service Date 12/8/62 6. Natior.at Board Number for Unit 14431'
7. Components Inspected i

Manufacturer l

Component or Manufacturer or Installer State or National l

Appurtenance or Installer Serial No.

Province No.

Board No.

I See Big Rod Ibint Power Plant

{

1993 Inservice inspection No. 3-1 Outage Plan

'i Reactor Vessel Canbustion Engineering 16512 M-064954-M 14431 Also see attached NIS-2 forms l

I 3

i P

l I

i

.i l

Note: Supplemental sheets in form of lists, sketches, or drawings may be used, provided (1) size is 8% in. x I1 in.,

(2) information in items I through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/s21 This Form (E00079) may be obtained from the Order Dept., ASME,345 E.47th St.,New York, N.Y.10017 i

i

e s

i FORM NIS 1 (Back) i

8. Examination Datas 6-28-93 8-25-93
9. Inspection Interval from _1-1-92 _ to ~12-31-2001 to

{

10. Abstract of Examinations. Include a list of examinations and a statement concerning status of work required.

-f' for current interval.

See ISI Report Table 2 l

11. Abstract of Conditions Noted j

See ISI Report Table 1

12. Abstract of Corrective Measures Recomrnended and Taken See ISI Report Table 1

[

t We certify that the statements made in this report are correct and the examinations and corrective mea-sures taken conform to the rules of the ASME Code, Sectic.n XI.1986 Felition Certificate of Authorization No. (if applicable) n/a Expiration Date n/a j

Date October 18 19.9_3__ signed Consumers Power Co.sy -

[

Owner CERTIFICATE OF INSERVICE INSPECTION I, the unde: signed, holding a valid egmgssion issued by the N tional Board of Boiler and Pressure VesselInspectors M

gan

.ind employed by on Mutual og and the State or Province of NomoodoM have inspected the components described in this wner s epo he period 6-28-93 to B-25-93

, and state that to the best of my knowledge and belief,the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the i

requirements of the ASME Code,Section XI.

4 -

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinatinns and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer sha!! be liable in any manner for any personalinjury or property damage or a loss of any kind arising from or connected with thisinspection.

Factory Mutual Engr. Assn Commissions k, 7(oo2 Inspecior's Signature National Board, State, Province, and Endorsements Date

/O - /k 19 1 t:2/82) i

)

~i

)

4 r,-

4

I FORM Nis 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI 1 o nor Consmers Power Ctmpany o,,, October 18, 1993 Name 212 W. Michigan Ave., Jackson, MI 49201 1

1 sheet of Address

2. Plant Big Rock Point Nuclear Plant 1

unit Nom.

10269 US 31 North, G arlevoix, MI 49720 to-92-FWS-0008 Addr see Repolt Orpentration P.O. No., Job No., etc.

3. Work Performed by Consmers PNer %3nY Type Code Symbol stamp N/A Authoritation No.

N/A 10269 US 31 North, Garlevoix, MI 49720 g,p;,,,;,n o,,,

N/A Ad drene

4. Identification of System P h ter @ h
5. (a) Applicable Construction Code ASME B31.1 3, 55 goi,,on, th th goo,no Code Case (b) Applicable Edition of Section XI Utilised for Repairs or Reptocements 19 86
6. Identification of Components Repaired or Raptaced and Replacement Components ASME Code National
Repaired, Stamped Name of Name of Manufacturer Board Other Yest
Replaced, (Yes Component Manufacturer Serial No.

N o, Identification Built D' Replacement or Not M IEr QIIIQ1 ftsplating Wlve Gaquuis Irt: I6ZT4 IVA ON00C 1990 Rpbrrrl 16

7. Description of Work Replaced Feedeter Regulating Valve
8. Tests Conducted: Hrdrostatic @ Preumstic Nominal Operating Pressure O Other] Pressure 2520 psi Test Temp.__65 r

NOTE: Supplemental sheets in form of lists, sketches, or drawings iney be used, provided til site is 8% in. x 11 in., (2) informs-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

(12/821 This Form (E00030) may be otneined from the Order Dept., A$ME,345 E. 47th St., New York, N.Y.10017

j 1

t i

FORM NIS-2 (Beck) f

9. Remerks Appilceble Manufacturer's Date Reports to t>e efteched j

t i

I i

CERTIFICATE OF COMPLIANCE We certihr that the statements arr de in the report ere correct end this M)lNMonforms to the ruiss of the I

'*P'"D****"'

ASME Code,Section XI, i

N/A Type Code Symbol $temo i

certificate of Authorization No, N/A r,p;,,,;,, o,,, N/A ISI Coordinator hedvire.-

[6 ig 'f 3 9,,,

~

signed e

Owner er Owner's Desiones, T#tte CERT 8FICATE OF INSERVICE INSPECTION -

-i holding a votid commission luued tnr the National Board of Boiler and Pressure Vessel inspectors and the $ tete k

I, the undersigned.idgan N h l I M rance h of M

=nd employed tsy or Province of N

E have -insucted the components' described 6-28-93 8-25-93

_ end tiete thet to in this owner s Report during the period to the test of my knowtedae end desief, the owner has performed eseminettons and teken corrective measures describedin this Owner's Report in accordence with the requirernents of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any worrenty, expressed or implied, concerning the

[

examirwtions and corrective measures described in this owner t Report, rurthermore, neither the inspector nor his employer j

shell be 16ebte in eny menner for any personet Iriury of property demeos or a loss of any kind erlsing from or connected with this _

j

+

inspection Commissions

' Wspector's Signature Neuonal Board, State, Province, and E noorsements

/o-/6

3. W f

osie (12/82) i P

b

l i

I r

I FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS l

As Required by the Provisions of the ASME Code Section XI f

1

5. con, Consumers Iber Conpany

.o,,, October 18, 1993 name 212 W. Michigan Ave., Jackson, MI 49201.

1 1

-l 33,,,

u dr j

2. Pl nt Big Rock Point Nuclear Plant 1

unit j

nome 10269 US 31 North, Charlevoix, MI 49720 lo-Irr,-12301596 i

Marsee Repair oreenirstion P.o. No., Jon No., etc.

f

3. Work Performed by Consumers M Co.

N/A Type code symbol Stone N/A Authortretion No.

10269 US 31 North, Charlevoix, MI 49720 N/A c,p;,,,3, o,,,

Address

4. Identificetion of System Reactor Vessel Head
s. (a) Applicable Construction Code ASME B31.1 to SS Edition, h Addenda _ h

_ Code Case l

(b) Applicable Edition of Section XI UtillreJ for Herairs or Reptacements 19 Ob

6. Identificetion of Components Repaired or Repisced and Replacement Components i

i' ASME Code.

I National

Repetred, Stamped l

Name of Name of Manufacturer Board Other Year

Replaced,

- (Yes.

Component Manufacturer Serial No.

No.

Identification Bunt or Replacement or No) l i

IIIctrr H n3 N/A N/A N/A 3" Flange 1962 Replaced No i

gg

.I

7. Description ot work R0Placed 3" Reactor Head Vent Lin3 Flange t

B. Tests Condacted: Hydrostatic @ Pneumetic Nomine! Operating Pressure O Other O Pressu,e 147s

,si Ten Temp.

229

'r NOTE: Supplementat sheets in form of lists, sketches. or drawings mey be used, provided (1) size is 8% in a 11 in., (2) Inforrne.

I tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is l

recorded at the top of this form.

4 i

(12/B2)

This Form (E 00030) may be obtained from the Order Dept ASME. 345 E. 47th St. New York, N.Y.10017 I

1 t

l I

I l

FORM NIS 2 (Back)

9. Remarks Applicable Manufacturer's Date Reports to be etteched r

CERTIFICATE OF COMPLIANCE We certdy that the statements made in the report era correct and this TMNkonforms to the rules of the

'*"*iP'*'*""*"'

ASME Cooe,Section XI.

Type Code Symbol Stamp N/A N/A Certificate of Authorisation No. N/A Empiration Dei.

Ockbv i8 Signed h

ISI COOrdinatDr Date e

Owner or Ownere Desionee. Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned holding a velid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State N NU lI M

W of b@

and employed by or Province of No h, E have inspected the components described 6-28-93 8-25-93

, and, tete thei in this owner's Report during the period to the best of my knowledge end belief, the Owner hos performed examinations and teken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificato neither the inspector not his employer makes any warranty, expressed or impfied, concerning the examinations and corrective measures described in this Owner) Report. Furthermore, neither the inspector nor his employer sha!! be lieble in any manner for any personal injury or property s'emage or a loss of any kind arisin0 rom or connected with this f

inspection.

Factory Mutani Engr. Assn.

Commissions N 7 c/

inspectors sieneture National Doord, State, Province, and Endorsements

/0-/2,,93 o,,e am

l FORM NIS 2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

-i i

t. owne, Cammrs Pwer COnpany n,,, October 18, 1993

~ e.

1 1

212 W. Michigan Ave., Jacksmi, MI 49201 sne,t Adorsee

2. Piant Big Rock Point Nuclear Plant unit 1

~arne 10269 US 31 North, ciarlevoix, MI 49720 K)-RSD-12301111 Addrees Repelt Orpenta etion P.O. No., Job No., etc.

I

3. Work Performed by COnSmers PCWer COnpany Type Code Symbol StW N/A l

N/A Authorization No.

10269 US 31 North, Charlevoix, MI 49720 g,p;,,,;on o,,e N/A Address

4. Identificetion of System Main Steam
5. (a) Applicable Construction Code ASME B31.1 is 55 Edition, lh Addende. None Code' Case.

(b) Applicable Edition of Section XI Utilized for Repairs or Reptocements 19 06

{

6. Identification of Cornponents Repaired or Reptoced sad Replacement Components r

ASME i

Code National

Repaired, Stamped Nome of Name of Menviseturer Board Other Year
Reptoced, (Yee Component Manufacturer Serial No.

No.

Identification Built or Reptocement or No) i F

i 1.5-MTr114 WA WA WA

$_h 1962 Reind I Pb l

[

i

7. Description of Wort Rfinir Weld

+

r

8. Tests Conducted; Hydrostetic Pneumatic Nominal Operating Pream-e other O Pres.,1475 psi ves: Temp. 229

+i; NOT E; Supplemental sheets in form of lists, sketches, or drewings mey be used, providec iI) sire is 8% in. x 11 in (2) informe-tion in items 1 through G on this report is included on each sheet, and (3) each sheet is nurnberar.) and the number of sheets is recorded et the top of this form. '

t (12/82)

This Form (E00030) may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017

l

4 b

I k

FORM NIS 2 (Back) 8

9. Remarks Applicable Manufacturer's Date Reports to be etteched e

CERTIFICATE OF COMPLIANCE T @ kE

' conforms to the rules of the

[

We certif y that the statements made in the report are correct and this

'**

  • O' '*P'" * ** at ASME Code, Section X1.

f N/A Type Code Symbol Starno Certificate of Authorization No. N/A g,p;,et;on osta N/A Ooh - (8 is e ISI Coordinator-oste Signed C

e Owr (er or Owner's Des.pnos. Title i

CERTIFICATE OF INSERVICE INSPECTION f, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State Mdm hl Iwan h og_

Midi @

and empioved try or Province of N

M have inspected the components described e

8-25-93

. and state that 6-28-93 in this Owner's Report during the period to the best of my knowledge and befief, the Owner has performed exarninstions and taken corrective rnessures described in this Owner's Report in accordence with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the eneminations and corrective eneasures described in this Owner's Report. Furthermore, neither the inspector nor his employer 3

shell 14 liebte in any menner for any personst 'niury or property damage or a loss of any kind arising from or connected with this inspection' Factory Mutual Engr. Assn.

j Commissions

/e inspector's Signature National Seerd. State, Province, and Endorsemems -

lo -/8,, 93 os,e n2mi

.9.

a FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI.

'f j

1. owner _ Consuners Iber COnpany oste Octrher 18, 1993 Nome 212 W. Middaan Ave. Jackson, MI 49201 Sheet 1

of 1

Addr eae

2. Pt nt Big Rock Point Nuclear Plant yo;,

1 usme i

r 10269 US 31 North, Otarlevoix, MI 49720 K)-RVG-12301490

=

Addross mopelt Orgenlaetion P.O. No., Job No., etc.

N/A

3. Work Performed by COnSunerS M CO*

Type Code Symhol Sternp Name N/A Authorization No.

10269 US 31 North, Charlevoix, MI 49720 t,,;,, tion os,e N/A j

Addreen

4. Identification of System Reactor Vent DkB l

E. (a) Applicable Construction Code N B31.1_ i9 55 Edition, None Addende M Code Case (b) Applicable Edition of Section XI Utittred for Repairs or Replacements 19 86

6. Identification of Components Repaired or Replaced and Replacement Components f

ASME Code National

Repelred, Stemped i

Name of Name of Manufacturer Board Other

' Year '

Reptoced, (Yes Component Manufacturer Serial No.

No.

Identification Built or Reptocement or No!

N/A N/A N/A

1. N 117 Q

Rplzad W

i i

i

7. Description of Work ReplaCOd IOaCtDr Vent lido frOm EOSCtDr head to shield tank.
8. Tests Condseted: Hydrostatic @ Pneumatic Nominst Operating Pressure O l

other O Preii re 1475 ai Te ' Tema 229

  • r l

l

  • JOT E: Supplementat sheets in iorm of fists, sketches, or drawings mey be used, provided (1) sire is 8% in. m 11 in., (2) informe-tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded et the top of this form, f

l (12/B2)

This Form (E00030! may be obtained from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017 l

.n.

j

.I a

~

i l

i

.I FORM NIS 2 (Back) i t

9. Remarks f

Applicatste Menuf eturer's Date Meports to t>e ettached t

.l.

I l

'f J

~l i

CERTIFICATE OF COMPLIANCE We certify that the statements made in the report are correct and this M aced ' conforms to the rules of the ASME Code,Section XI.

- '***i'*********'

'l

.i N/A Type Code Symbol Stamp Certificate of Authorization No. N/A Expiration Dete N/A C & *' IO 93 ISI CoordinatOf Date

_19

$;gned Owner or Owner's Des pnee, Title CERTIFICATE OF INSERVICE INSPECTION

(

t, the undersigned, hold;ng a vefid commission issued ty the National Board of Boiler and Pressure Vessel Inspectors and the State l

Fivbillon Mutual Insuranm tw=umr EdNW and employed ty g

o or Psovince of Nonood, R have inspected the components described 25-93

_ end Mate that -

in this Owner's Report during the period 6-28-93 to to the best of my knowledge and belief, the Owner has performed examinations and teken corrective measures described in this -

i Owner's Report in accordance with the requirements of the ASME Code', Section Kl.

l By signing this certificate neither the inspector nor his employer enskes any worrenty, empressed or irnpfled, concerning the

.l examinations and corrective enessures described in this Owner's Report. Furthermore, nehher the inspector not his employer shall be liable in any manner for any personal inju or property damage or a loss of any kind arising from or connected with this inipeciioa-Factnty Mutual Engr. Assn.

{

j N

Commissions inspectors signature Notenal Board. State, farovince, and E r dorsements

/O-/8 is b D.te i

.5 (12/82) l

s a

.i FORM NIS-2 OWNER'S REPORT FOR REPAIRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI December 10, 1992 Consumers Power Company Date 1 Owner Name 212 W. Michigan Ave., Jackson, MI 49201 Sheet 1

of 1

Address Big Rock Point Nuclear Plant unit 1 2, Plant Name 10269 US 31 North, Charlevoix, MI 49720 M>-92-RDS-0037 & IO-92-11rr-0041

}

P.epair orsentr etion P.0, No., Job No., etc.

Adoress

3. Work Performedby Big Rock Point P1 ant Type Code Symbol Stamp N/A N/A Authorization No.

N/A 10269 US 31 North, Charlevoix, MI 49720 Expiration Date Address

4. Identification of System Reactor Deprgssurization System ASME
5. (a) Applicable Construction CodeSection III

.9 71 _ Edition, NA Addenda, N Code Case (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 $6

6. Identification of Components Repaired or Replaced and Replacement Components ASME Code
Repaired, Stamped National Name of Name of Manufacturer Board Other Year
Replaced, (Yes Component Manufacturer Serial No.

No, Identification Built Of Replacement or No)

Flange Inlet SV-4984 N/A N/A N/A Bolting 1975 Feplaced No ange hiet SV-4985 N/A N/A N/A Bolting 1975 Replaced No I

7. Description ot Work Replace Inlet Flange Bolting
8. Tests Conducted: Hydrostatic Pneumatic 0 Nominal Operating Pressure @

Other O Pressure 1335 psi Test Temp.

585

  • r f

Supplemental sheets in form of lists, sketches, or drawings may be used, provided til she is 8% in. x 11 in., (2) informa-r NOTE.:

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

This f orm (E00030) may be ob:s;ned from the Order Dept., ASME,345 E.47th St., New York, N.Y.10017 (12/82)

,n

6 b

l i

FORM NIS 2 (Back)

9. Remarks Applicable Manufacturer's Date Reports to t>e attached CERTIFICATE OF COMPLlANCE 7/e certify that the statements made in the report are correct and this replacement conforms to the rules of the

'*"*i'*""'"'

ASME Code,Section XI.

F Type Code Symbol Stamp 3IA Certificate of Authorirstion No,M/N Expiration Data _ N b ISI Coordinator Date Us-U

_19 1 -

Signed Owner or Owner's Designee. Title 1

CERTIFICATE OF INSERVICE INSPECTION l, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of _._ Michigan and employed byProtection Mutual Insurance company of

.,Eoaopd, MA have inspected the components described in this Owner's Report durin0 the period IS 'O

  • E=1 to IN 'll
  • f I

_ and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASfAE Code,Section XI, By signing ttus certifcate neither the inspector nor his entployer makes any warranty, empressed or implied, concerning the esaminations and corrective measures described in this Owner's Report, Furthermore, neither the inspector nor his erriployer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

FACTORY MUTUAL SYSTEM Commissions NI~b2 J d~ t/

Inspector's Segnature Nationet posed State, Province, and E noorsements Date M -//

19_fs2 02/82) f 1

1 l

1 FORM NIS 2 OWNER'S H2 PORT FOR REPAlRS OR REPLACEMENTS As Required by the Provisions of the ASME Code Section XI

1. Owner _ Consumers Powe r Company page December 10, 1992 Name 212 W. Michigan Ave., Jackson, MI 49201 Sheet 1

of 1 Addr ess 2, Plant Big Rock Point Nuclear Plant Unit 1

Name 30269 US 31 North, Charlevoix, MI 49720 to-92-F0S-0040 Address Pepair orpeninetion P.O. No., Job No., etc.

3. Work Performedby Consumers Power Company Type Code Symbol Stamp N/A Authorization No.

N/A

[

10269 US 31 North, Charlevoix., MI 49720 Expiration Date N/A Address Reactor Depressurization System

4. Identifration ot System
5. (a) Applicable Construction Code Section IIIjg 71
Edition, N/A Addenda _ N CodeCese 86 (b) Applicable Edition of Section XI Utilized for Repairs or Replacements 19 i
6. Identification of Components Repaired or Replaced and Replacement Components ASME 4

Code

Repaired, Stamped National Name of Name of Manufacturer Board Other Year
Reptoced, (Yes Component Manufacturer Serial No.

No.

Identification Bullt or Replacement or No)

Branch Con-N/A N/A N/A 1.5-10 S-112-11 1975 repaired No nection Socket Weld

.1 7 Description ot Work repaired weld 1.5-RDS-112-11 B. Tests Conducted; Hydrostatic A Pneumatic 0 Nominal Operating Pressure O Other O Pre >>ure 1475 pii Test Temp-70

'r Supplemental sheets in form of hsts, sketches, or drawings may be used, provided (1) size is 84 in. x 11 in, (2) inforrne-NOTE:

tion in items 1 through 6 on this report is included on each sheet, and (3) each sheet is numbered and the numiser of sheets is a

recorded at the top of this form.

112/82)

This Form (F00030) may te obtained f rom the Order Dept., ASME,345 E. 47th St., New York, N.Y.10017

a FORM NIS-2 (Back)

9. Remarks Applicable Manuf acturer's Data Reports to t>e ottached CERTIFICATE OF COMPLlANCE We certify that the statements made in the report are correct and this rePM conforms to the rules of the

P**P'*****"'

ASME Code,Section XI.

Type Code Symbol StampMA Certificate of Authorization No._il/A Expiration Date _ $3/4 Signed A

ISI Coordi n LQL.Oate

%2.- M

_19,9 2_

Owner or Owner's Desieries. Title CERTIFICATE OF INSERVICE INSPECTION t, the undersigned, holdmg a valid commission issued by the National Board of Boiler and Pressure Vessel inspectors and the State or Province of Michigan and employed by Protection Mutual Insurance company of Norwood, MA have inspected the components described O ~ 7"N to /d *//

  • YE

, and state that in this Owner's Report during the period to the best of my knowledge cnd belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code.Section XI.

By signing this certificate neither the inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures describnf in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising ito'm or connected with this inroection.

FACTORY MUTUAL SYSTEM i

Commissions N1. b2 h,A inspector's Signature Nationet Board, State. Province, and Endorsements O

19 N Date e

02/82)

J I

4

Page 1 of 1 -

9 BIG ROCK POINT NUCLEAR PLANT -

INSERVICE INSPECTION 311 DISPOSITION OF REPORTABLE INDICATIONS 1

TABLE 1 EXAM COMPONENT EXAM REPORTING NUMBER IDENTIFICATION METHOD CONDITION REPORTED MECHANISM DISPOSITION REEXAM-DISPOSITION _

3-6 2-RDS-107A-03-PR-2 FUNCT.

BENT SHAFT D-BRP-93 035 REPLACED WITH VT & FUNCTIONAL ACCEPTABLE Pee Snubber PS-115B SPARE SNUBBER OF REPLACEMENT 11,-g 1.5-MSS-117-1 E

LINEAR INDICATION D-BRP-93-034 REPLACED LINE E.

ACCEPTABLE Fla_nge-to-Pee REEXAMINE 11-6 1.5-MSS-117-2 H

LINEAR INDICATION D-BRP-93-034 REPLACED LINE E

ACCEPTABLE Pee-to-Elbow REEXAMINE 11-8 1.5-MSS-117-3A E

LINEAR INDICATION D-BRP-93-034 REPLACED LINE E

ACCEPTABLE Pipe-to_-F,_lb_o_w REEXAM!NE 11-11 1.5-MSS-117-6 5

LINEAR INDICATION D-BRP-93-034 REPLACED UNE E

ACCEPTABLE Elbow-to-Pipe REEXAMINE 11-12 1.5 MSS-117-7 U

LINEAR INDICATION 0-BRP-93-034 REPLACED LINE E

ACCEPTABLE Pipe-to-Elbow REEXAM!NE l

l m-.

=.

=

~

Page 1 of 6 BIG ROCK POINT NUCLEAR PLANT INSERVICE INSPECTION 3/1 TABLE 2 i

EXAM ASME ASME EXAM COMPONENT EXAMINATION NUMBER ITEM CATEGORY METHOD IDENTIFICATION RESULTS 11 eul Aua.

EI RV-5002 (F-1)

Acceptable Steam Drum - Relief Valve 1-2 E-M-2 S12.50 VT-3 10-FWS-101 Acceptable VFW-304

_2d Aua.

IGSCC UT 24-MRS-121-01 Acceptable Reducer-to-Tee 2-2 Aua.

IGSCC UI 5-MRS-131-01 Acceptable Branch Connection-to-Pipe 2-3 Aua.

IGSCC UT 5-MRS-131-02 Acceptable Pipe-to-Elbow 2-3 Aua.

IGSCC UI 5-MRS-131-03 Acceptable Elbow-to-Pipe 3-1 E-C F3.10 VT-3 2-RDS-107A-03-PR-1 Acceptable Pipe Snubber PS-115A 3-2 E-C F3.50 VT-3 2-RDS-107A-03-PR-1 Acceptable Pipe Snubber PS-115A 33 T.S.

FUNCT.

FUNCT, 2-RDS-107A-03-PR-1 Acceptable Pipe Snubber PS-115A 3-4 E-C F3.10 VT-3 2-RDS-107A-03-PR-2 Acceptable Pipe Snubber PS-115H 3-5 F-C F3.50 VT-3 2-RDS-107A-03-PR-2 Acceptable Pipe Snubber PS-115B

}-g LS

FUNCT, FUNCT.

2-RDS-107A-03-PR-2 See Table 1 Pipe Snubber PS-115B 5

~

Page 2 of 6 BIG ROCK PGNT NUCLEAR PLANT INSERVICE INSPECTION 3/1 TABLE 2 EXAM ASME ASME EXAM COMPONENT EXAMINATION NUMBER ITEM CATEGORY METHOD IDENTIFICATION RESULTS E

E-C F3.10 VT-3 10-RDS-103D Acceptable Pipe Snubber PS-1093 M

E-Q F3.50 VT-3 10-RDS-103D Acceptable Pipe Snubber PS-109A M

T.S.

FUNCT.

FUNCT.

10-RDS-103D Acceptable Pipe Snubber PS-109A 3-10 E-Q F3.10 VT-3 10-RDS-103D Acceptable Pipe snubber PS-1098 3-11 E-Q F3.50 VT-3 10-RDS-103D A_cceptable Pipe Snubber PS-109B 3-12 13 FUNCT.

E_UNCT.

10-RDS-103D Acceptable Pipe Snubber PS 109B g-1

Ava, IGSCC

_UT 14-MRS-101-05 Acceptable Pipe-to-Safe End g-g

bug, IGSCC

_UT 14-MRS-101-06 Acceptable Safe End-to-Nozzle g-J Aua.

IGSCC

_Ul 14-MRS-102-06 Acceptable Pipe-to-Safe End 6_-4 Aua.

IGSCC Ul 14-MRS-102-07 Acceptable Safe End-to-Nozzle 6_ -j Aug_

IGSCC UT 14-MRS-103-05 Acceptable Pipe-to-Safe End J.GS_C_C UT 14-MRS-103-06 Acceptable S

$3 Agt Safe End-to-Nozzle

~-

Page 3 of 6 BIG ROCK POINT NUCLEAR PLANT INSERVICE INSPECTION 311 TABLE 2 EXAM ASME ASME EXAM COMPONENT EXAMINATION NUMBER ITEM CATEGORY METHOD IDENTIFICATION RESULTS g-Z Aua.

IGSCO MI 17-MRS-113-01 Acceptable Nozzle-to-Safe End i

D-g Aua.

LGSCC MT 17-MRS-113-02 Acceptable Safe End-to-Pipe Q-9 Aua.

IGSCC UT 17-MRS-114-01 Acceptable Nozzle-to-Safe End 6-10 Aua.

IGSCC MI 17-MRS-114-02 Acceptable Safe End-to-Pipe 11-1 Aug IGSCC UI 4-RDC-101-09 Acceptable Pipe-to-Elbow I

11-2 M

B9.11 UT.PT 4-RDC-101-12 Acceptable Pipe-to-Elbow fj-3 Aua IGSCC UT 4-RDC-101 12 Acceptable Pipe-to-Elbow 11-4 Aug IGSCC UI 4-RDC-101-13 Acceptable Elbow-to-Pipe 11-5 BJ B9.40 EI 1 5-MSS-117-1 See Table 1 Flanae-to-Pipe 11-6 M

B9.40 El 1.5-MSS-117-2 Acceptable Pipe-to-Elbow 11-7 B-J B9 40 PT 1.5-MSS-117-3 Acceptable i

Elbow-to-Pipe l

11-8 M

89.40 EI 1.5-MSS-117-3A See Table 1 Pipe-to-Elbow i

Page 4 of 6 BIG ROCK POINT NUCLEAR PLANT INSERVICE INSPECTION 3/1 TABLE 2 EXAM ASME ASME EXAM COMPONENT EXAMINATION NUMBER

? TEM CATEGORY METHOD IDENTIFICATION RESULTS B

B9.40 E

1.5-MSS-117-4 Acceptable J

11-9 Elbow-to-Pipe 11-10

@-J B9.40 1.5-MSS-117-5 Acceptable Pipe-to-Elbow 11-11

@-J 89.40 1.5-MSS-117-6 See Table 1 Elbow-to-Pipe 11-12 S-J B9.40 E

1.5-MSS-117-7 See Table 1 Pipe-to-Elbow 11-13

.BJ B9.40 E

1.5-MSS-117-8 Acceptable Elbow-to-Pipe i

11-14 B-J

@9 40 E

1.5-MSS-117-9 Acceptable Pipe-to-Elbow 11-15 B-J B9.40 PT 1.5-MSS-117-10 Acceptable Elbow-to-Pipe 11-16 S-J B9.40 1.5-MSS-117-11 Acceptable Pipe-to-Flance 11-17 S-F 85140 E

807-4A Acceptable Nozzle-to-Flance i

11-18

@-F B5140 E

807-4B Acceptable Nozzle-to-Flanae 11-19 B-F B5.140 PT 307-4B1 Acceptable Nozzle-to-Flance 19-1 Aug Aua UT CRD Housing Acceptable CRD F-2

Page 5 of 6 BIG ROCK POINT NUCLEAR PLANT INSERVICE INSPECTION 311 TABLE 2 EXAM ASME ASME EXAM COMPONENT EXAMINATION NUMBER ITEM CATEGORY METHOD IDENTIFICATION RESULTS A

Aua.

E J-Weld Acceptable 193 A

CRD F 2 19-3 An aul

_U_I Reactor Vessel Wall AcEntable CRD F-2 19-4 Aua.

Aug UI Stub Tube-to-Vessel Wall Acceptable CRD F-2 i

i 6

1

Page 6 of 6 i

BIG ROCK POINT NUCLEAR PLANT INSERVICE INSPECTION 311 TABLE 2 PRESSURE TESTS ASME ASME EXAM SYSTEM EXAMINATION ITEM CATEGORY METHOD IDENTIFICATION RESULTS t

g-P B15,51 VT-2 PRIMARY SYSTEM ACCEPTABLE CLASS 1 PIPING j

AND COMPONENTS C-H C7.10 VT-2 SHUTDOWN COOLING SYSTEM ACCEPTABLE C7 20 C7.30 C7.40 t

I