ATTACHMENT 2 LICENSE AMENDMENT APPLICATION, LCR 93-05, NLR-N93169 ULTIMATE HEAT SINK TEMPERATURE CHANGES REVISED TECHNICAL SPECIFICATION PAGE i
FACILITY OPERATING LICENSE NPF-57 i
HOPE CREEK GENERATING STATION DOCKET NO. 50-354 REVISED TECHNICAL SPECIFICATION PAGE WITH PEN AND INK CHANGES The following Technical Specifications for Facility Operating License No. NPF-57 are affected by this RAI:
Technical Specification Paaes I
3.7.1.3 3/4 7-5 9
i
.L I
L 4
Y i
i I
t'
?
'I l
l l
9312010322 931110 PDR ADOCK 05000354 P
PDR i
\\
.a PLANT SYSTEMS ULTIMATE HEAT SINK LIMITING CONDITION FOR OPERATION I
3.7.1.3 The ultimate heat sink (Delaware River) shall be OPERABLE with:
a.
A minimum river water level at or above elevation -13'O Mean j
Sea Level, USGS datum (76'O PSE&G datum), and a
ggj p l
b.
An average river water temperature of less than or equal toPJ0W.j 1
APPLICABILITY:
OPERATIONAL CONDITIONS 1, 2, 3, 4, 5 and *.
ACTION:
e 145ce v kron w%c. bel
(*ge-m p
lWth AfiejegyJ(emgts,4f tad' abpve sp6cjlicapi'on p6t sat'isfiedVl a.
In OPERATIONAL CONDITIONS 1, 2 or 3, be in at least HOT SHUTDOWN within 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> and in COLD SHUTDOWN within the next 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
b.
In OPERATIONAL CONDITIONS 4 or 5, declare the SACS system and the
{
station service water system inoperable and take the ACTION required by Specification 3.7.1.1 and 3.7.1.2.
c.
In Operational Condition *, declare the plant service water system inoperable and take the ACTION required by Specification 3.7.1.2.
The provisions of Specification 3.0.3 are not applicable.
SURVEILLANCE REQUIREMENTS
- 4. 7.1. 3 The ultimate heat sink shall be determined OPERABLE:
a.
By verifying the river water level to be greater than or equal to the minimum limit at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.
b.
By verifying river water temperature to be within its limit:
i 1-) at least once per 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> when the river water temperature is less tnan or equal to 85'F.
- 2) at least once pe when the river water temperature is greater than 85'F.
"When handling irradiated fuel in the secondary containment.
HOPE CREEK 3/4 7-5
)
~__
r l'
t i
i INSERT FOR PAGE 3/4 7-5 With the river water temperature in excess of 88.6*F, but at or below 89.9'F, continued plant operation is permitted for 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> provided that both loops of SACS /SSWS are verified to be OPERABLE; otherwise, with the requirements of the above specification not satisfied: