l, O * * * %<,
l l.
k
/
,g l
E 9"
E UNITED STATES l
l'
- f NUCLEAR REGULATORY COMMISSION
[
WASHINGTON. D.C. 20555-0001
[
....a l
CONNECTICUT YANKEE ATOMIC POWER COMPANY DOCKET NO. 50-213 HADDAM NECK PLANT t
AMENDMENT TO FACILITY OPERATING LICENSE s
Amendment No. 163 License No. DPR-61 l
1.
The Nuclear Regulatory Commission (the Commission) has found that:
A.
The application for amendment by Connecticut Yankee Atomic Power Company (the licensee), dated March 18, 1993, complies with the standards and requirements of the Atomic Energy Act of 1954, as i
amended (the Act), and the Commission's rules and regulations set l
forth in 10 CFR Chapter I; i
B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without endangering the health and-safety of the public, and (ii) that such activities will be i
conducted in compliance with the Commission's regulations;
)
D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
93KP9140<hs2 930902 PDR ADOCK 05000213-P PDR
2 i 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. DPR-61 is hereby amended to read as follows:
1 (2) Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No.163, are hereby incorporated in the license.
The licensee shall operate the facility in accordance with the l
Technical Specifications.
3.
This license amendment is effective as of the date of issuance, to be implemented within 30 days of issuance.
{
FOR THE NUCl. EAR REGULATORY COMMISSION of Y
c
,1 JYK)
John F. Stolz, Director Project Directorate I-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation
Attachment:
j Changes to the Technical l
Specifications Date of Issuance:
September 2, 1993 O
+.
l 1
ATTACHMENT TO LICENSE AMENDMENT NO. 163 FACILITY OPERATING LICENSE NO. DPR-61 DOCKET NO. 50-213 Replace the following page of the Appendix A Technical Specifications with the enclosed pag =.
The revised page is identified by amendment number and contains vertical lines indicating the areas of change.
Remove Insert 3/4 4-17 3/4 4-17 l
i i
i
,-v w
,y
S i
REACTOR COOLANT SYSTEM OPERATING LIMITING CONDITION FOR OPERATION l
3.4.2.2 All pressurizer Code safety valves shall be OPERABLE with respective l!ft settings of 2485 psig 1%, 2535 psig 1% and 2585 psig 1%
i in accordance with their respective nameplates.*+
l APPLICABILITY: MODES 1, 2, and 3.
ACTION:
l With one pressurizer Code safety valve inoperable, either restore the inoperable valve to OPERABLE status within 15 minutes or be in at least HOT STANDBY within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in at least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
SURVEILLANCE REOUIREMENTS 4.4.2.2 In addition to the requirements of Specification 4.0.5, each pressurizer Code safety valve shall be demonstrated OPERABLE by checking its setpoint each refueling.
i The lift setting pressure shall correspond to ambient conditions of the valve at nominal operating temperature and pressure.
i i
1% applies when a safety valve is tested and set prior to installation
+
( as-l e f t). When a safety valve is removed and tested, the as-found setting may be within +3% and -l% of the setpoint.
l l
l gDDAMNECK 3/4 4-17 Amendment No. JJJ,163,
.