WASWNGTON, D.C. 255-tm SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION RELATED TO AMENDMENT NOS.173 AND154 TO FACILITY OPERATING tICENSE N05. NPF-4 AND NPF-7 VIRGINIA ELECTRIC AND POWER COMPANY OLD DOMINION ELECTRIC COOPERATIVE NORTH ANNA POWER STATION. UNITS NO. 1 AND NO. 2 DOCKET NOS. 50-338 AND 50-339 l.0 INTRODUCTION t
t By letter dated July 2,1993, the Virginia Electric and Power Company (the licensee) proposed changes to the Technical Specifications (TS) for the North Anna Power Station, Units No. 1&2 (NA-1&2).
Specifically, the changes would revise the NA-l&2 TS 3/4.6.1.2 by removing the schedular requirements for Type A tests to be performed at 40i10 month intervals and instead reference Type A testing in accordance with Appendix J to 10 CFR Part 50.
The changes would also include several editorial / administrative changes.
The NA-]&2 TS currently require a set of three containment integrated leakage rate (Type A) tests be performed specifically at 40 10 month intervals during each 10-year service period with the third test of each set performed during the shutdown for the 10-year plant inservice inspection. Appendix J to 10 CFR Part 50 requires that a Type A test of the containment be performed periodically.
These tests are required to be scheduled as a set of three tests, to be l
performed at approximately eoual intervals, during each 10-year service period with the third test of each set to coincide with the shutdown for the 10-year plant inservice inspection. While the NA-l&2 TS leakage rate testing requirements essentially duplicate the requirements in Appendix J, the TS 1
additionally require the Type A test be performed at 40 10 month intervals.
1 This TS requirement to conduct Type A tests at 40!10 month intervals is too restrictive.
Therefore, the licensee proposes to revise the NA-l&2 TS to delete the detailed surveillance schedule for the Type A tests and instead reference performance of Type A testing in accordance with Appendix J to 10 CFR 50.
2.0 DiswQqn
~
The TS-required schedule provides only a 20-month window for scheduling of Type A tests. This requirement is not appropriate for a facility like NA-l&2 which is on an 18-month fuel cycle. An 18-month fuel cycle does not provide sufficient flexibility for three tests within a 10-year service period when limited by the stipulation that the tests be performed at 40 10 months intervals.
s
- u"Esuansjk l
P
i I
- I
, l i
i During the first 10-year service period for both NA-l&2, TS change requests were submitted requesting approval to deviate from the TS-specified Type A test schedule.
Each of these change requests proposed to alter the schedule by only a few months. However, since such a change has been needed in the past and needed for the current and future service period, the TS requirement is evidently too restrictive.
l l
For 18-month fuel cycles, the Type A tests must be conducted every other i
refueling outage to be within the 30- to 50-month range allowed by the TS for i
the first and second test of the service period.
Then, however, an extension is needed to make tne third and last test coincide with the 10-year inservice inspection outage. Therefore, the licensee would revise the NA-l&2 TS to i
refer to 10 CFR Part 50, Appendix J, which requires only that the tests be conducted "at approximately equal intervals" during the 10-year service period with the third test being conducted during the service inspection outage.
Typically, this would result in tests being conducted at intervals of 4h years, 3 years, and 3 years over a 10-year period.
3.0 Technical Soecfication Chances.
TS Surveillance Requirement 4.6.1.2.a would be revised to remove the specific requirement that the Type A tests be performed at 40 10 month intervals with the third test of each set conducted during the shutdown for the 10-year plant inservice inspection.
The revised requirement _would read:
j
" Type A (Overall Integrated Containment Leakage Rate) tests shall be i
conducted in accordance with the requirements specified in Appendix J to l
10 CFR 50."
l TS Surveillance Requirements 4.6.1.2.b and 4.6.1.2.c would be deleted.
The licensee stated that these surveillance requirements are also specified in Appendix J to 10 CFR 50 and need not be reiterated in the technical specifications.
However, surveillance requirement 4.6.1.2.c.3 is not specified in Appendix J to the same level of detail. This surveillance requirement concerns the accuracy of supplemental testing.
i Section 111.A.3(b) of Appendix J states the requirements for the accuracy l
of supplemental testing in terms of a fraction of L,, while surveillance requirement 4.6.1.2.c.3 is related to a specific test and its success criteria. Although the requirement is not specified in the same level of detail in Appendix J as in the technical specification surveillance requirement, the staff finds the deletion of this survaillance requirement acceptable because:
(1) the requirement for a supplemental test and general requirements for the accuracy of the test are specified i
in Appendix J, and (2) it is not necessary for the technical specifications to contain the level of detail specified in section 4.6.1.2.c.3.
In fact, the new Westinghouse Standard Technical
)
Specifications are consistent with the licensee's proposal in this
.I i
respect. The remaining Surveillance Requirements would be renumbered Dr continuity.
Consistent with this renumbering, the reference in TS 1
1
- ~-. -.
l
)
4.6.1.1.c is revised from " Specification 4.6.1.2.d" to " Specification l
4.6.1.2.b."
.i The format of TS 3.6.1.2.a would be revised to eliminate the single l
subsubparagraph and delete the word "or" at the end of_the statement.
l Both the subsubparagraph format and the conjunction word are unnecessary.
The original format was taken from the Standard Technical Specifications t
(STS) for Westinghouse Pressurized Water Reactors.
The STS had two options under Specification 3.6.1.2.a; however, NA-l&2 were not licensed.
for the second option. This proposed format change does not change the intent of the TS.
i TS 3.6.1.2.a would be revised to add the phrase "the calculated peak l
containment pressure" as a description in front of the term "P,."
The addition of this phrase provides clarificatii and does not change the i
intent of the TS.
r I
Remove the footnotes on the bottom of the NA-l&2 TS Page 3/4 6-2.
]
Removing these special requirement footnotes would not constitute a i
i change to the TS. The special requirements were applicable to a specific j
cycle or outage.
The special requirements have been completed and the i
e footnotes are no longer applicable.
i 4.0 Evaluation 4
Satisfactory leakage results are a requirement for the establishment of f
containment operability..Neither the general frequency nor the required l
number of Type A tests would be changed by the proposed changes.
Also, the maximum allowable leakage rate at the calculateu peak containment pressure i
would not be changed.
Only the detailed 4010 month test interval would be
)
changed to provide more flexibility. Type A, B, and C tests would continue to i
be performed in accordance with Appendix J to 10 CFR 50.
Type A test j
acceptance criteria would not be changed and combined leakage of penetrations subject to Type B and C tests would be maintained within the required limits.
i Also, the proposed changes do not impact the design basis of the containment and would not change the response of containment during a design basis accident.
Finally, the testing method, acceptance criteria, and Bases to the TS are not changed by the proposed revisions to the TS.
Therefore, based on all of the above, the staff finds the proposed changes to be acceptable.
5.0 STATE CONSULTATION
In accordance with the Commission's regulations, the Virginia State official was notified of the proposed issuance of the amendments.
The State official had no comment.
3 j
9
6.0 ENVIRONMENTAL CONSIDERATION
This amendment changes a requirement with respect to installation or use of a facility component located within the restricted area as defined in 10 CFR Part 20 and changes surveillance requirements. The NRC staff has determined that the amendments involve no significant increase in the amounts, and no t
significant change in the types, of any effluents that may be released offsite, and that there is no significant increase in individual or cumulative occupational radiation exposure. The Commission has previously issued a i
proposed finding that these amendments involve no significant hazards consideration and there has been no public comment on such finding (58 FR 41517). Accordingly, these amendments meet the eligibility criteria for categorical exclusion set forth in 10 CFR 51.22(c)(9). Pursuant to 10 CFR 51.22(b) no environmental impact statement or environmental assessment need be prepared in connection with the issuance os the amendments.
7.0 CONCLUSION
The Commission has concluded, based on the considerations discussed above, that:
(1) there is reasonable assurance that the health and safety of the public will not be endangered by operation in the proposed manner, (2) such activities will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendments will not be inimical to the common i
4 defense and security or to the health and safety of the public.