REVISED COPY t-d-
co***3*******************************==*************************************
UNIT;l OPERATING DATA REPORT
- oo**************************************************************************
Docket No. 50-317 August 12, 1993 Prepared by Frank Piazza Telephone: (410)260-3821 OPERATING STATUS
- 3. UNIT NAME Calvert Cliffs Unit 1 7.
REPORTING PERIOD JUNE 1993 3.
LICENSED THERMAL POWER (MWT) 2700 4.
NAMEPLATE RATING (GROSS MWe) 918 5.
DESIGN ELECTRICAL RATING (NET MWe) 845 6.
MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 860 7.
MAXIMU:1 DEPENDABLE CAP'Y (NET MWe) 830 8.
CHANGE IN CAPACITY RATINGS NONE 9.
POWER LEVEL TO WHICH RESTRICTED N/A
- 10. REASONS FOR RESTRICTIONS N/A Cumulative.
I This acnth
_____________' lear-to-Date to Date R11. HOURS IN REPORTING PERIOD 720 4,343 159,084
- 12. NUMBER OF HOURS REACTOR WAS CRITICAL 579.0 4,202.0 112,552.0
- 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0
'3,019.4-
- 14. HOURS GENERATOL ON LINE 559.5 4',182.5 110,161.4
- 15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 16'.. GROSS THERMAL ENERGY GENERATED (MWH) 1,479,117 11,217,991.278,496,842
- 17. GROSS ELECTRICAL ENERGY GEN'TED(MWH) 488,044 3,770,439 92,597,973
- 18. NET ELECTRICAL ENERGY GENERATED (MWH) 464,053 3,617,633 88,087,019
- 19. UNIT SERVICE FACTOR
'/7.7 96.3 69.2
- 20. UNIT AVAILABILITY FACTOR 77.7 96.3 69.2
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 77.7 100.8 67.1
- 22. UNIT CAPACITY FACTOR (USING DER NET) 76.3 98.6 65.5
- 23. UNIT FORCED OUTAGE RATE 22.3 3.7 9.0-24.' SHUTDOWNS SCHEDULED OVER THE NEXT f
SIX MONTHS (TYPE, DATE AND DURATION):
N/A i
- 25. IF SHUTDOWN AT END OF REPORT. PERIOD, ESTIMATED DATE OF START-UP:
N/A l
9308100174'930G12 ET ADDCKOSOOO317fg
.?DR PDR g
R
~
4 RERASED COPY QQ**************************************************************************-
UNIT 2 OPERATING DATA REPORT.
00**************************************************************************
j Docket No. 50-318 August 12, 1993 i
Prepared by Frank Piazza Telephone: (410)260-3821 OPERATING STATUS l
F
- 1. UNIT NAME Calvert Cliffs Unit 2
- 2. REPORTING PERIOO JUNE 1993 l
3.
LICENSED THERMAL POWER (MWT) 2700 4.
NAMEPLATE RATING (GROSS MWe) 911 5.
DESIGN ELECTRICAL RATING (NET MWe) 845
~!
6.
MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 860
.}
- 7. MAXIMUM DEPENDABLE CAP'Y (NET MWe) 830 8.
CHANGE IN CAPACITY. RATINGS NONE 9.
POWER LEVEL TO WHICH RESTRICTED N/A i
- 10. REASONS FOR RESTFTCTIONS N/A Cumulative' This' month Year-to-Date.to Date
- 11. HOURS IN REPORTING PERIOD
, 720 4,343 142,439'
- 12. NUMBER OF HOURS' REACTOR WAS CRITICAL 451.8 1,655.4 101,619.8
' 13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1,~ 2 9 6. 6 -
i
- 14. HOURS GENERATOR sN :,T.N E 368.5 1,570.2 100,152.0 l'
- 15. UNIT RESERVE SH'JTD011N HOURS 0.0 0.0 0.0
- 16. GROSS THERMAL E4ERGY GENERATED (MWH) 800,569 4,022,693 255,167,485
- 17. GROSS-ELECTRICA.' ENERGY GEN'TEP'MWH) 257,901 1,330,548 -84,289,326
- 18. NET ELECTRICAL ENERGY GENERATT
'4H )
236,239 1,264,911 80,533,340
+
4
- 19. UNIT SERVICE FACTOR 51.2
'36.2 70.3
- 20. UNIT AVAILABILITY. FACTOR 51.2 36.2 70.3
- 21. UNIT CAPACITY FACTOR (USING MDC NET) 39.5 35.3 63.5 l
'22.
UNIT CAPACITY FACTOR (USING DER NET) 38.8 34.5 66.9
- 23. UNIT FORCED OUTAGE RATE 11.4 2.9 5.9
- 24. SHUTDOWNS SCHEDULED OVER THE NEXT l
SIX MONTHS (TYPE, DATE AND DURATION):
N/A 25, IP UNIT IS SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START-UP:
N/A'-
l L
L