ML20056D862

From kanterella
Jump to navigation Jump to search
Revised Monthly Operating Repts for May 1993 for Ccnpp,Units 1 & 2
ML20056D862
Person / Time
Site: Calvert Cliffs  
Issue date: 05/31/1993
From: Piazza F
BALTIMORE GAS & ELECTRIC CO.
To:
Shared Package
ML20056D847 List:
References
NUDOCS 9308180172
Download: ML20056D862 (2)


Text

-

- REVISED COPY 0c**************************************************************************-

UNIT 1 OPERATING DATA REPORT

.co**************************************************************************

Docket'No. 50-317.

August 12, 1993 Prepared by Frank-Piazza Telephone: (410)260-3821 OPERATING STATUS

1. UNIT NAME Calvert Cliffs Unit 1.

2.

REPORTING PERIOD MAY 1993

3. LICENSED THERMAL POWER (MWT) 2700
4. NAMEPLATE RATING (GROSS MWe) 918 5.

DESIGN ELECTRICAL RATING (NET MWe) 845 6.. MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 860

7. MAXIMUM DEPENDABLE CAP'Y (NET MWe) 830

'8.

CHANGE IN CAPACITY RATINGS NONE 9.

POWER LEVEL TO WHICH RESTRICTED N/A

-10.

REASONS FOR RESTRICTIONS N/A Cumulative This month Year-to-Date to Date-

11. HOURS IN REPORTING PERIOD 744 3,623 158,364
12. NUMBER OF HOURS REACTOR WAS CRITICAL 744,0 3,623.0 111,973.0.
13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 3,019.4
14. HOURS GENERATOR ON LINE 744.0 3,623.0 109,601.9
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0
16. GROSS THERMAL ENERGY GENERATED (MWH) 1,996,482 9,738,874 277,017,725
17. GROSS ELECTRICAL ENERGY GEN'TED(MWH) 670,614 3,282,395 92,109,929
18. NET ELECTRICAL ENERGY GENERATED (MWH) 643,286 3,153,580 87,622,966-

- 19. UNIT SERVICE FACTOR 100.0 100.0 69.2

.20. UNIT AVAILABILITY FACTOR 100.0 100.0 69.2

21. ' UNIT. CAPACITY FACTOR (USING MDC NET) 104.6 105.5 67.1-
22. UNIT CAPACITY FACTOR (USING DER NET) 102.3 103.0 65.5-
23. UNIT FORCED OUTAGE RATE 0.0 4.2 9.1 24.-SHUTDOWNS SCHEDULED OVER THE NEXT SIX. MONTHS (TYPE, DATE AND DURATION):

N/A 25.-IF SHUTDOWN AT END OF REPORT PERIOD, ESTIMATED DATE OF START-UP:

N/A-

$Bih k

s

  • ~

RE/ISED COPY co**************************************************************************

UNIT 2 OPERATING DATA REPORT Jc***************************************************************************

Docket No. 50-318 August 12, 1993 Prepared by Frank Piazza Telephone: (410) 260-3 821 OPERATING STATUS T

1. UNIT NAME Calvert Cliffs Unit 2 2.

REPORTING PERIOD MAY 1993 3.

LICENSED THERMAL POWER (MWT) 2700

~

4. NAMEPLATE RATING (GROSS MWe) 911
5. DESIGN ELECTRICAL RATING (NET MWe) 845 l

6.

MAXIMUM DEPENDABLE CAP'Y (GROSS MWe) 860 7.

MAXIMUM DEPENDABLE CAP'Y (NET MWe) 830 l

8.

CHANGE IN CAPACITY RATINGS

.NONE k

9.

POWER LEVEL TO WHICH RESTRICTED N/A j

10. REASONS FOR RESTRICTIONS N/A Cumulative-This month Year-to-Date to Date j
11. HOURS IN REPORTING PERIOD 744 3,623 141,719
12. NUMBER 0F HOURS REACTOR WAS CRITICAL 0.0 1,203.6 101,168.0.

j

13. REACTOR RESERVE SHUTDOWN HOURS 0.0 0.0 1,296.6
)
14..HOURSEGENERATOR ON.LINE 0.0 1,201.7 99,783.5_
15. UNIT RESERVE SHUTDOWN HOURS 0.0 0.0 0.0 i
16. GROSS ~ THERMAL ENERGY GENERATED (MWH)-

0 3,222,124 254,366,916

17. GROSS ELECTRICAL ENERGY-GEN'TED(MWH)-

0 1,072,647 84,031,425

18. NET ELECTRICAL ENERGY GENERATED (MWH) 0 1,028,672 80,297,101

~

19.-UNIT SERVICE FACTOR 0.0 33.2 70.4 i

-20. UNIT AVAILABILITY' FACTOR 0.0 33.2 70.4

21. UNIT CAPACITY FACTOR (USING MDC NET) 0.0 34.4 68.7' l'
22. UNIT CAPACITY. FACTOR (USING DER NET) 0.0 33.6' 67.1
23. UNIT FORCED OUTAGE RATE 0.0 3.8 24.' SHUTDOWNS SCHEDULED OVER THE'NEXT

' 6.0 i

I SIX MONTHS (TYPE, DATE'AND DURATION):

N/A l

25. IF. UNIT IS SHUTDOWN AT END OF REPORT PERIOD,

-l ESTIMATED'DATE OF START-UP' l

N/A i

i I

l

}

i

-)

t

.