ES-401 Written Examination Review Worksheet Form ES-401-9 Facility: BYRON NUCLEAR GENERATING STATION Exam Date: Oct 28 - Nov 12, 2019 Refer to Section D of ES-401 and Appendix B for additional information regarding each of the following concepts.
- 1. Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.
- 2. Enter the level of difficulty (LOD) of each question using a 1 (easy) to 5 (difficult); questions with a difficulty between 2 and 4 are acceptable.
- 3. Check the appropriate box if a psychometric flaw is identified:
Stem Focus: The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).
Cues: The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length).
T/F: The answer choices are a collection of unrelated true/false statements.
Cred. Dist>: The distractors are not credible; single implausible distractors should be repaired, more than one is unacceptable.
Partial: One or more distractors are partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).
- 4. Check the appropriate box if a job content error is identified:
Job Link: The question is not linked to the job requirements (i.e., the question has a valid K/A but, as written, is not operational in content).
Minutia: The question requires the recall of knowledge that is too specific for the closed-reference test mode (i.e., it is not required to be known from memory).
- /Units: The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).
Backward: The question requires reverse logic or application compared to the job requirements.
- 5. Check questions that are sampled for conformance with the approved K/A and those that are designated SRO-only. (K/A and license-level mismatches are unacceptable).
- 6. Enter question source: (B)ank, (M)odified, or (N)ew. Verify that (M)odified questions meet criteria of ES-401 Section D.2.f.
- 7. Based on the reviewers judgment, is the question, as written, (U)nsatisfactory (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?
- 8. At a minimum, explain any U status ratings (e.g., how the Appendix B psychometric attributes are not being met).
Page 1 of 7 Q#
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
B/M/N
- 7.
U/E/S
- 8.
Explanation NRC developed exam. ES-401-9 only used for statistical / metric documentation.
Stem Focus Cues T/F Cred.
Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only 1
H 3
N 2
H 3
B NRC 2006 Byron ILE 3
H 2
B NRC 2017 Byron ILE (previous 2 NRC Exams) 4 H
3 N
5 H
2 B
6 H
3 N
7 F
3 N
8 H
3 N
9 H
4 M
ES-401 2
Form ES-401-9 Facility: BYRON NUCLEAR GENERATING STATION Exam Date: Oct 28 - Nov 12, 2019 Page 2 of 7 Q#
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
B/M/N
- 7.
U/E/S
- 8.
Explanation NRC developed exam. ES-401-9 only used for statistical / metric documentation.
Stem Focus Cues T/F Cred.
Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only 10 F
3 N
Question 10 deleted during the grading process. Final written examination and answer key revised to reflect the deletion. Reference Byron Exam Report 05000454/2019302; 05000455/2019302, Enclosure 2, for NRC disposition of the post-exam comments submitted by the Licensee for this question.
11 F
3 N
12 F
3 B
NRC 2014 Braidwood ILE 13 H
3 B
14 F
2 B
NRC 2014 Byron ILE 15 H
3 N
16 F
3 B
NRC 2010 Ginna ILE 17 H
3 N
18 F
2 B
19 H
3 N
20 F
3 M
21 H
3 N
22 H
3 M
23 F
3 N
24 F
3 N
25 F
3 M
26 F
2 N
27 F
2 B
28 F
2 N
29 H
3 B
30 F
2 B
ES-401 3
Form ES-401-9 Facility: BYRON NUCLEAR GENERATING STATION Exam Date: Oct 28 - Nov 12, 2019 Page 3 of 7 Q#
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
B/M/N
- 7.
U/E/S
- 8.
Explanation NRC developed exam. ES-401-9 only used for statistical / metric documentation.
Stem Focus Cues T/F Cred.
Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only 31 H
3 B
32 H
2 N
33 H
3 M
34 H
2 N
Embedded Graphic: Plant Computer Data Handout for PRT.
35 H
3 N
36 H
3 N
37 F
2 B
38 H
3 B
39 H
3 B
40 H
3 N
41 H
2 N
Reference provided: BAR 2-4-B3, SOLID STATE PROT CAB GENERAL WARNING 42 F
2 M
43 H
2 B
44 H
2 N
45 F
2 N
46 H
2 N
47 F
3 N
48 H
4 N
49 H
3 B
50 H
3 N
51 F
3 N
52 F
3 N
53 F
2 N
54 H
3 N
ES-401 4
Form ES-401-9 Facility: BYRON NUCLEAR GENERATING STATION Exam Date: Oct 28 - Nov 12, 2019 Page 4 of 7 Q#
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
B/M/N
- 7.
U/E/S
- 8.
Explanation NRC developed exam. ES-401-9 only used for statistical / metric documentation.
Stem Focus Cues T/F Cred.
Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only 55 H
3 N
56 F
2 N
57 H
4 N
58 F
2 B
NRC 2012 Prairie Island ILE 59 H
2 B
NRC 2016 Byron ILE 60 F
3 N
61 H
2 B
62 F
2 N
63 F
3 B
64 F
3 B
NRC 2013 Braidwood ILE 65 H
3 N
66 H
3 N
Reference Provided: BTC 1.3, Boric Acid Storage Tanks 1/2AB03T 67 F
2 B
NRC 2009 Braidwood ILE 68 F
2 N
69 F
2 N
70 H
2 N
71 F
3 N
72 F
2 B
NRC 2011 Salem ILE 73 H
2 N
74 F
2 M
2 N
76 H
3 N
Reference Provided: EAL Matrix 77 F
3 N
78 H
4 N
Reference Provided: FIGURE 1BOA RCP-1-1, NO. 1 SEAL NORMAL OPERATING RANGE
ES-401 5
Form ES-401-9 Facility: BYRON NUCLEAR GENERATING STATION Exam Date: Oct 28 - Nov 12, 2019 Page 5 of 7 Q#
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
B/M/N
- 7.
U/E/S
- 8.
Explanation NRC developed exam. ES-401-9 only used for statistical / metric documentation.
Stem Focus Cues T/F Cred.
Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only 79 H
3 N
Reference Provided: LCO 3.8.1, AC Sources - Operating 80 H
3 N
81 F
3 N
82 H
2 N
Reference Provided: EAL Matrix 83 H
3 N
84 H
3 N
85 H
2 B
NRC 2014 Byron ILE 86 H
3 N
87 H
3 N
88 H
3 N
Reference Provided: LCO 3.8.4, DC Sources - Operating 89 H
3 N
Reference Provided: LCO 3.8.1 90 F
2 N
91 F
3 N
92 F
2 N
Correct answer for Question 92 changed from choice C to A during the grading process. Final written examination and answer key revised to reflect the answer change. Reference Byron Exam Report 05000454/2019302; 05000455/2019302, Enclosure 2, for NRC disposition of the post-exam comments submitted by the Licensee for this question.
93 H
2 N
94 F
4 N
Question 94 deleted during the grading process. Final written examination and answer key revised to reflect the deletion. Reference Byron Exam Report 05000454/2019302; 05000455/2019302, Enclosure 2, for NRC disposition of the post-exam comments submitted by the Licensee for this question.
95 H
3 N
96 H
2 N
97 H
2 N
ES-401 6
Form ES-401-9 Facility: BYRON NUCLEAR GENERATING STATION Exam Date: Oct 28 - Nov 12, 2019 Page 6 of 7 Q#
- 1.
LOK (F/H)
- 2.
LOD (1-5)
- 3. Psychometric Flaws
- 4. Job Content Flaws
- 5. Other
- 6.
B/M/N
- 7.
U/E/S
- 8.
Explanation NRC developed exam. ES-401-9 only used for statistical / metric documentation.
Stem Focus Cues T/F Cred.
Dist.
Partial Job-Link Minutia
- /
units Back-ward Q=
K/A SRO Only 98 H
2 N
99 F
3 M
NRC 2016 Byron ILE 100 F
2 N
ES-401 Written Examination Review Worksheet Form ES-401-9 Facility: BYRON NUCLEAR GENERATING STATION Exam Date: Oct 28 - Nov 12, 2019 Page 7 of 7 RO TOTALS:
B= 24 F= 35 34*
E= N/A Additional Notes: NRC developed exam. ES-401-9 only used for statistical documentation.
- RO Question 10 deleted during the grading process.
M= 7 H= 40 U= N/A N= 43*
SRO TOTALS:
B= 1 F= 8 7**
E= N/A Additional Notes: NRC developed exam. ES-401-9 only used for statistical documentation.
SRO Question 92 answer changed from choice C to A during the grading process.
- SRO Question 94 deleted during the grading process.
M= 1 H= 17 U= N/A N= 23 22**
GENERAL COMMENT
S:
- 2.
Questions from the previous 2 NRC Exams: __1__(RO)/__0__(SRO)
- 3.
Average difficulty is _2.63 2.62*_ on the RO exam and 2.72 2.71** on the SRO exam.