Proposed Tech Specs,Deleting Section 6.2.3, Independent Safety Engineering Group (Iseg) & Associated Administrative Controls
ML20056B508
Person / Time
Site: Shoreham File:Long Island Lighting Company icon.png
Issue date: 08/21/1990
From:
LONG ISLAND LIGHTING CO.
To:
Shared Package
ML20056B505 List:
References
NUDOCS 9008280380
Download: ML20056B508 (2)


Text

n h *,[

ADMINISTRATIVE CONTROLS

~

f.O INDEPENDENT SAFETY ENGINEERING GROUP (ISEG) (Deleted)

L i

(

l i

6.2.4 SHIFT TECHNICAL ADVISOR 6.2.4.1' The Shift Technical Advisor shall provide advisory technical support to the Watch Engineer in the areas of thermal hydraulics, resctor engineering, and plant analysis with regard to safe operation of the unit. The Shift Technical Advisor thall have a bachelor's degree or equivalent in a

ientific or engineering discipline and shall have received specific training in the response and analysis of the unit for transients and accidents, and in unit aesign and layout. including the capabilities of instrumentation and controls in the control room.

6.3 UNIT STAFF QUALIFICATIONS 6.3.1 -

Each member of the unit staff shall meet or exceed the minimum l

qualifications of ANSI N18.1-1971 for comparable positions and the supplemental 4

requirements specified in Sections A and C of Enclosure 1 of the March 28, 1980 1

NRC letter to all'11censees, except for the Health Physics Engineer who shall meet or exceed the qualifications of Regulatory Guide 1.8, September 1975. The

licensed Operators and Senior Operators shall also meet or exceed the minimum qualifications of the supplemental requirements specified in Section A and C of

. Enclosure 1 of the March 28, 1980 NRC letter to all licensees.

SHOREHAM - UNIT 1 6-6

%>R220390 900821

~

PDR~ ADUCK 05000322.

m H

PNU i

y 6 -,

y

a ADMINISTRATIVECONTRQS 6.4 TRAINING 6.4.1 A retraining and replacement training program for the station staff shall be maintained under the direction of the Training Supervisor, shall meet or exceed the requirements and recommendations of Section 5 of ANSI 18.1-1971 and-Appendix A of 10-CFR Part 55 and the supplemental requirements specified in i

Sections A and C of Enclosure 1 of the March 28, 1980 NRC letter to'all licensees, and shall include familiarization with relevant industry operational experience.-

l 6.5 REVIEW AND AUDIT 6.5.1 REVIEW OF OPERATIONS COMMITTEE (ROC)

FUNCTION 6.5.1.1 The ROC shall function to advise the Plant Manager on all me+.ters related to nuclear safety.

COMPOSIT10N e

6.5.1.2 The ROC shall be composed of the:

Chairman:

Operatio.; Manager 1

Alte-nate Chairman:

Plant Manager Alternate Chairman and Member:

Maintenance Manager-7 Member:

Operating Engineer Member:

Maintenance Engineer Member:

Instrament and Control Engineer Member:

Reactor Engineer Member:

Health Physics Engineer Member:-

Radiological Controls Manager ALTERNATES.

6.5.1.3 All alternate members shall be appointed in writing by the ROC Chairman; however, no more than two alternates shall participate as voting members in ROC activities at r.ay one time.

5 MEETING FRE0VENCY 6.5.1.4 The ROC shall meet at least once per calendar month and as convened by E

the ROC Chairman or his designated alternate.

QUORUM i

L

.6.5.1.5 The quorum of the ROC necessary for the performance of the ROC j

responsibility and authority provisions of these Technical Specifications shall consist of the Chairman or his designated alternate and four other members including alternates, y

J l

SHOREHAM - UNIT 1 6-7 I

L 4

,