ML20055B803

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Radiographic Test Indications on Safety Injection Tanks & Reactor Pump Supports.Ebasco & C-E Directed to Assure Evaluation of safe-end Indications Are Performed.Final Rept by 820815
ML20055B803
Person / Time
Site: Satsop
Issue date: 07/01/1982
From: Leddick R
WASHINGTON PUBLIC POWER SUPPLY SYSTEM
To: Bishop T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION V)
References
10CFR-050.55E, 10CFR-50.55E, 23, G3-82-675, GO3-82-675, NUDOCS 8207230312
Download: ML20055B803 (1)


Text

a Docket Nos. 50-508/509 f -

50.55(e) Report L %'fE!)

Washington Public Power Supply System g'

Box 1223 Elma, Washington 98541 (206)482-4428

~_ PP G y

' July 1, 1982 G03-82-675 Docket Numbers 50-508 and 50-509 U. S. Nuclear Regulatory Commission, Region V Office of Inspection and Enforcement 1450 Maria Lane, Suite 260 Walnut Creek, California 94596-5368 Attention:

Mr. T. W. Bishop Chief, Reactor Construction Projects Branch

Subject:

POTENTIAL 10CFR50.55(e) DEFICIENCY RT INDICATIONS, SAFETY INJECTION TANKS AND REACTOR PUMP SUPPORTS lD/N #23)

References:

a) NRC letter dated June 22, 1982, T. W. Bishop to R. S. Leddick, same subject, b) Letter, G03-82-564, dated June 4, 1982, R. S. Leddick to T. W. Bishop, same subject.

In response to reference a),the Supply System has always acknowledged the need for assuring that the WNP-3 Safety Injection Tanks are fabricated in accordance with all Code and SAR requirements. Therefore, the Supply System will expand the response regarding the disposition and corrective actions for linear indications found in the safe-end welds of Safety Injection Tanks #3 and #4.

Ebasco, in conjunction with Combustion Engineering, has been directed to assure an evaluation of the safe-end indications per 10CFR50.55(e) is per-formed.

In addition, CE has connitted to repair the safe-end indications after Supply System review of the proposed CE repair plan.

The information required to supplement the final report for the subject condition (Reference b) will be forwarded to your office by August 15, 1982.

Should you have any questions or desire further information, please contact me directly.

s+-

,R. S. Leddick Program Director, WNP-3 cc: Mr. J. A. Adams, NESCO Mr. D. Smithpeter, BPA WNP-3/5 Files, Richland l{Q]

8207230312 820701 PDR ADOCK 05000508 S

ppg g.). g -