JUL 031982
Docket 50-247
Consolidated Edison Company of
New York, Inc.
ATTN.
Mr. John D. O'Toole
Vice President - Nuclear
Engineering and Quality Assurance
4 Irving Place
Gentlemen:
Subject:
Inspection No. 50-247/ 82-10
This refers to the routine safety inspection conducted by Dr. P. K. Eapen
of this office on May 24 through 28, 1982, at Indian Point 2 and at your
corporate offices, of activities authorized by NRC License No. DPR-26 and
to the discussions of our findings held by Dr. Eapen with Mr. Zarakas and
other members of your staff at the conclusion of the inspection.
Areas examined during this inspection are described in the NRC Region I
Inspection Report which is enclosed with this letter. Within these areas,
the inspection consisted of selective examinations of procedures and representative
records, interviews with personnel, and observations by the inspector.
Based on the results of this inspection, it appears that certain of your
activities were not conducted in full compliance with NRC requirements, as
set forth in the Notice of Violation, enclosed herewith as Appendix A.
These violations have been categorized by severity level in accordance with
the NRC Enforcement policy (10 CFR 2, Appendix C) published in the Federal
Register Notice (47 FR 9987) dated March 9, 1982. You are required to
respond to this letter and in preparing your response, you should follow
the instructions in Appendix A.
The responses directed by this letter and the accompanying Notice are not
subject to the clearance procedures of the Office of Management and Budget
as required by the Paperwork Reduction Act of 1980, PL 96-511.
In accordance with 10 CFR 2.790(a), a copy of this letter and the enclosures
will be placed in the NRC Public Document Room unless you notify this
office, by telephone, within ten days of the date of this letter and
submit written application to withhold information contained therein
within thirty days of the date of this letter. Such application must be
consistent with the requirements of 2.790(b)(1).
The telephone notification
of your intent to request withholding, or any :equest for an extension of
the 10 day period which you believe necessary, should be made to the
Supervisor, Files, Mail and Records, USNRC Region I, at (215) 337-5223.
0FFICIAL RECORD COPY
z
g0-
8207220504 820702
I
PDR ADOCK 05000247
G
._.
.
.
Consolidated Edison
Indian Point 2
2
Your cooperation with us in this matter is appreciated.
Sincerely,
original Signed By:
sTfiomas T. Martin, Director
.. b Division of Engineering and
Technical Programs
Enclosures:
1.
Appendix A, Notice of Violation
2.
NRC Region I Inspection Report Number 82-10
cc w/ enc 1:
C. W. Jackson, Vice President, Nuclear Power
K. Burke, Director, Regulatory Affairs
W. D. Hamlin, Assistant to Resident Manager (PASNY)
F. Matra, Resident Construction Manager
Lewis F. Liberatori, Nuclear Licensing Engineer
Thomas J. Farrelly, Esquire
Brent L. Brandenburg, Assistant General Counsel
Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
NRC Resident Inspector
State of New York
bcc:
Region I Docket Room (with concurrences)
Chief, Operational Support Section (w/o encis)
H. B. Kister
e
RI:DETP
RI:DETP
RI:DE
P.K.Eapen/jpf D.L Caphton
S.D.E neter
g{ Q7,
o
6/17/82
OFFIC L RECORD COPY
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _