s a

APPENDIX A NOTICE OF VIOLATION Carolina Power & Light Company Docket No. 50-261 H. B. Robinson 2 License No. DPR-23 As a result of tne inspection conducted on flarch 11 - April 10,1982, and in accordance with the NRC Enforcement Policy, 47 FR 9987 (Ibrch 9,1982), the following violation was identified.

10 CFR 20.203(c) requires that each high radiation area shall be conspi-cuously posted with a sign or signs designating the area a high radiation 1

area.

This requirement is implemented by Health Physics Procedure HP-1, Section 5.2.5.

Section 5.2.5 also requires that if the high radiation area

^

is not completedly bounded by physical barriers, those perimeters shall be cordoned off in a manner that clearly indicates the bounds of the area.

Contrary to the above, as of ilarch 26, 1982, this procedure was not imple-mented in that a high radiation area on the second level of containment was not posted for access from the northwest personnel stairway; and, as of April 7,1982, the high radiation area around the spent fuel pit heat exchanger was posted as a radiation area, i

This is a Severity Lev?1 V Violation (Supplement IV.).

Pursuant to the provisions of 10 CFR 2.201, you are hereby required to submit to this office within thirty days of the date of this Notice, a written statement or explanation in reply, including:

(1) admission or denial of the alleged viola-tion;-(2) the reasons for the violation if admitted; (3) the corrective steps which have been taken and the results achieved; (4) corrective steps which will be taken to avoid further violations; and (5) the date when full compliance will be achieved.

Consideration may be given to extending your response time for good cause shown.

l E

Da te:

i i

8206220545 920603 PDR ADOCK 05000261 e

PDR

. _.