Responds to NRC Re Violation Noted in IE Insp Repts 50-424/82-05 & 50-425/82-05.Identified Weld Meets Criteria for Undercut.Violation Contested
ML20054G726
Person / Time
Site: Vogtle  
Issue date: 04/26/1982
From: Foster D
GEORGIA POWER CO.
To: Long F
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML20054G719 List:
References
GN-169, NUDOCS 8206220243
Download: ML20054G726 (2)


Text

. - _ _ _ _ _ _ _ _ _ _ _ _ _

o

^

ma k I 6 i tsNRO PEM "'

Georgia Power CorkanyyT f., 3 E L i s v ' <*

Post Office Box 4545 Atlanta, Georgia 30302 b

'*'*P""a434S y y 4 A8.3 ygg gqg Southern Company Seryges, Inc.

Post Office Box 2625 Birmingham, Alabama 35202 Telephone 205 870-6011 April 26, 1982 United States Nuclear Regulatory Commission Office of Inspection and Enforcement Region II Suite 3100 101 Marietta Street Atlanta, Georgia 30303

Reference:

ID:

II:

50-424/82-05 50-425/82-05 File: X7BG10 Log:

GN-169 Attention:

F. J. Long Gentlemen:

The Georgia Power Company wishes to submit the following information concerning the violation discussed in your inspection report 50-424/82-05 and 50-425/82-05.

We do not concur w:th the finding identified concerning " Failure to Follow Inspection Procedure". A group of qualified visual welding inspectors performed a thorough inspection of the affected weld. The total length of the vertical weld was measured to be fifty six and one half inches (56S").

The affected area of underfill was approximately seven inches (7") or 12 percent of the weld length. The worst area of the weld was marked using a one inch grid and the underfill was measured in each grid. There was no underfill that exceeded one-sixteenth (1/16) of an inch.

The width of the weld crown did not vary unreasonably and the group concluded that the fit-up of the plates prior to welding exaggerated the appearance of the underfill in the final weld.

Based on our inspection the weld in question meets the criteria for undercut (underfill) as specified in specification X2AP01.

gyEtCI AI C l

8206220243 82061o I

DR ADOCK 05000424 PDR

. Mr. F. J. Long 50-424/82-05, 50-425/82-05 April 26, 1982 Page 2 This response contains no proprietary information and may be placed in the NRC Public Document Room,upon receipt.

Very truly yours, D. O. Foster Project General Manager xc:

U. S. Nuclear Regulatory Commission Attn: Victor J. Stello, Jr., Director Office of Inspection and Enforcement Washington, D. C.

20555 R. J. Kelly R. E. Conway G. F. Head J. T. Beckham, Jr.

J. H. Boykin D. E. Dutton R. H. Pinson D. L. McCrary R. A. Thomas J. A. Bailey

0. Batum H. H. Gregory, III E. D. Groover L. T. Gucwa M. Malcom C. R. Miles, Jr.

M. Manry R. W. Staffa J. L. Vota W. F. Sanders - Resident Inspector 1

.