ML20054G298

From kanterella
Jump to navigation Jump to search
Ro:On 820513,error Discovered in Odyn Transient Code Which Could Result in .01 Nonconservatism in Cycle 3 Limiting Condition for Operation for Max Critical Power Ratio.Caused by Incorrect Programming in Axial Distribution Calculation
ML20054G298
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 05/13/1982
From: Curtis S, Nix H
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
NUDOCS 8206210394
Download: ML20054G298 (2)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _

~.

l 01 BAXLEY, GEORGIA 31513 PMS MR. JAMES P. O'REILLY UNITED STATES NUCLEAR REGULATORY COMMISSION a

DIRECTOR OF INSPECTION AND ENFORCEMENT N

E,53 REGION II v.

SUITE 3100 3

101 MARIETTA STREET

-t O

. c ATLANTA, GEORGIA 30303 m

o a

SUBJECT:

Hatch Unit 2, Docket No. 50-366, Notification c f Iggport'5ble Occurrence No. 50-366/1982-040 4

On.)

3..

NOTIMIED:

J.

Rogge tc C. ~ '

DATE: 5-13-82 DATE: 5-13-82 TIME:ll:45 CDT i

DESCRIPTION OF REPORTABLE OCCURRENCE Initial Condition At the time of discovery Unit 2 was in cold shutdown with mode switch in the refuel position.

Nature of Occurrence Site was notified by letter that an error had been discovered in the ODYN transient code which could have resulted in a

.01 non-conservatism in the Cycle 3 LCO for MCPR.

Immediate Corrective Action A.01 penalty will be incorporated into the MCPR limits for both fuel types.

As the unit had not begun Cycle 3 operation no other action was required.

Cause The error was the result of incorrect programing in the axial power distribution calculation.

Supplemental Corrective Action The vendor is reperforming the Cycle 3 analysis with a correct program.

Status of Redundant or Backup Systems The unit was not in operation at the time of discovery.

Impact to Other Unit The Unit 1 OLMCPR is based on the Rod Withdrawal Error and is not affected by the ODYN error.

Justification for Continued Operation A.01 additional penalty will be added to the Cycle 3 OLMCPR values to compensate for the error.

1819

/-

h Lk C 1 H.

C.

Nix Plant Manager 8206210394 820513 PDR ADOCK 05000366 q

PnR

9 CONFIRMATION STATEMENT _

2 0 Telea roin a-7a Vo For Document (Desttiption of Document)

I have checked the statements made in this document and, to the best of ray knowledge, the statements made in this response are gccurate.

(sign'ature) 5-/3-ft (Date)

L

'~~ " ' ' ~

- -,,.,, _ _,,