ML20053C674

From kanterella
Jump to navigation Jump to search
Ack Receipt of 811019,1218 & s Informing NRC of Steps Taken to Correct Nonconformance Noted in QA Program Insp Rept 99900294/81-01.Corrective Actions in Response to Items 4 & 5 & Preventive Action Re Item 6 Required
ML20053C674
Person / Time
Issue date: 03/26/1982
From: Potapovs U
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
To: Hoover D
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
Shared Package
ML20053C670 List:
References
REF-QA-99900294 NUDOCS 8206020454
Download: ML20053C674 (1)


Text

y!

ic O

P.AR 2 61982 Docket No. 99900294/82-01 Westinghouse Electric Corporation tiedium Motor and Gearing Division ATTil: Mr. D. L. Hoover General Manager P. O. Box 225 Buffalo,tiY 14240 Gentlemen:

Thank you for your letters of October 19, and December 18, 1981, and February 25, 1982, in responic to our letters dated September 11, and November 27, 1981, and January 26, 1982. As a result of our review, we find that additional information as discussed with your Mr. R. McKeever during a telephone call on March 15, 1982, is needed.

Our letters dated September 11, and November 27, 1981 and January 26, 1982, have requested that you identify entrective actions in regard to items 1, 2, 3, 4, and 5 (Notice of Nonconformance items A, B, C, D, and E). Review of your letters dated October 19, and December 18, 1981, and February 25, 1982, indicates that you still have failed to supply all the requested information. Your letters fail to supply the corrective actions taken in regard to items 4 and 5 (Notice of Ncnconformance, items D and E). Additionally, you have still failed to supply the pre-ventive action taken to assure comitments to the NRC will be implemented as stated in regard to item 6 (Notice of Nonconfomance, item F).

Please provide this additional information witisin 25 days from the date of this letter in order that we may complete our review.

Sincerely, "Origir.at Signed byj U. POTAPOVS'8 Uldis Potapovs, Chief Vendor Inspection Branch 8206020454 820527 PDR GA999 EMVWEST 99900294 PDR bcc:

WMMcNeill JAMarshall KVSeyfrit f

_ fn )

RIV Cl:R&Ce5 dC:Rkes bu:veulpovs....)p:lteVSe 'f i t...41001

/

Ha

"'C'>

.....WMMctleill/rf.....lBarna s..

OP 3/g82...3L

.sa....j 3/;.(y r-

..a/;

3/p6/82..

........9.(..........!.........

/.82

$~~>

  • * >l... N...

I wac roau sis oo<eoisacu o2do OFFICIAL RECORD COPY