Amend 73 to License NPF-1,revising Surveillance Requirements for Pressurizer power-operated Relief Valves
ML20053C493
Person / Time
Site: Trojan File:Portland General Electric icon.png
(NPF-01-A-073, NPF-1-A-73)
Issue date: 05/12/1982
From: Clark R
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20053C491 List:
References
NUDOCS 8206020226
Download: ML20053C493 (4)


Text

.

~

o $iag'o UNITED STATES y 4

/

g g

NUCLEAR REGULATORY COMMISSION l

WASHINGTON, D. C. 20555

%,.....f PORTLAND GENERAL ELECTRIC COMPANY THE CITY OF EUGENE, OREGON PACIFIC POWER AND LIGHT COMPANY DOCKET NO. 50-344 TROJAN NUCLEAR PLANT AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 73 License No. NPF-1 1.

The Nuclear Regulatory Commission (the Commission) has found that:,

A.

The application for amendment by Portland General Electric Company, the City of Eugene, Oregon, and Pacific Power and Light Company (the licensee) dated February 10, 1982 f.osplies with the standards and requirements of the Atomic Energy Act_ of 1954, as amended (the Act) and the Commission's rules and regulations set forth in 10 CFR-Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.

There is reasonable assurance (i) that the activities authorized by this amendment can be conducted 'without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations;

'D.

The issuance of this anendment will not be inimical to the common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Conmission's regulations and all applicable requirements have been satisfied.

l i

8206020226 820512 PDR ADOCK 05000344 P

PDR

4 2-2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License flo. HPF-1 is hereby amended to read as follows:

l (2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 73, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications except as noted in paragraph 2.C.(11) bel ow.

- 3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR REGULATORY COMMISSION

/APAaFL '

~

Robert A. Clark, Chief Operating Reactors Branch #3 Division of Licensing

Attachment:

Changes to the Technical Specifications Date of Issuance:

May 12, 1982 9

9 A

+

e G

9 e

--- ~

- - -. - - - _ = _ -. _ _ _ _. _. _ _ _ _ _ _ _ _ _

b ATTACHMENT TO LICENSE AMENDMENT AMENDMENT N0. 73 TO FACILITY OPERATING LICENSE NO. NPF-1 DOCKET N0. 50-344 Revise Appendix A as follows:

Remove Pages Insert Pages 3/4 4-4a 3/4 4-4a l

W e

l 4

REACTOR COOLANT SYSTEM 3/4.4.3 SAFETY AND RELIEF YALVES - OPERATING RELIEF VALVES LIMITING CONDITION FOR OPERATION 3.4.3 2 Two power operated relief valves (PORVs) and their associated block valves shall be OPERABLE.

. APPLICABILITY:

MODES 1, 2 and 3.

ACTION:

a.

With one or more PORV(s) inoperable, within 1 hour1.157407e-5 days <br />2.777778e-4 hours <br />1.653439e-6 weeks <br />3.805e-7 months <br /> either restore the PORY(s) to OPERABLE status or close the associated block valve (s) and remove power from block valve (s); otherwise, be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the following 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

b.

With one or more block valve (s) inoperable, within l' hour either restore the block valve (s) to OPERABLE status or close the block valve (s) and remove power from the block valve (s), or close the PORV(s) and remove control power from the PORYls); otherwise, be in at least HOT STANDBY within the rext 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in COLD SHUTDOWN within the follow..g 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br />.

c.

The provisions of 3.0.4 are not applicable.

SURVEILLANCE REQUIREMENTS 4.4.3.2.1 In addition to the requirements of Specification 4.0.5, each PORV shall be demonstrated OPERABLE at least once per 18 months by:

a.

Performance of a CHANNEL CALIBRATION, and b.

.0perating the valve through one comp 1.ete cycle of full travel.

4.4.3.2.2 Each block valve shall be demonstrated OPERABLE at least once per 92 days by operating the valve through one complete cycle of full travel unless the block valve is closed with power removed in order to meet the requirements of Specification 3.4.3.2.a.

TROJAN-UNIT 1 3/4 4-4a Amendment No. 7.3 9

O