Fifth Interim Deficiency Rept Re Seismic Qualification of B&W Equipment in TVA Panels,Initially Reported 801124.All But 32 of 253 Devices Have Been Determined Acceptable.B&W Will Consider Requalification to Higher G Level
ML20053B972
Person / Time
Site: Bellefonte  
Issue date: 05/18/1982
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
RTR-NUREG-0588, RTR-NUREG-588 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8206010386
Download: ML20053B972 (2)


Text

i a

s' NRO 0

TENNESSEE VALLEY AUTHORITY-4NT4 g,

' 9 [j,

CH ATTANOOG A. TENNESSEE 37401

^

/

k,f4 y g 400 Chestnut Street Tower II

/

9. O,.

May 18, 1982 U.S. Nuclear Regulatory Commission Region II Attn:

Mr. James P. O'Reilly, Regional Administrator 101 Marietta Street, Suite 3100 Atlanta, Georgia 30303

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - SEISMIC QUALIFICATION OF B&W EQUIPMENT IN TVA PANELS - NCR BLN BLP 8011 - FIFTH INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector R. W. Wright on November 24, 1980 in accordance with 10 CFR 50.55(e).

This was followed by our interim reports dated December 23, 1980 and April 23 and October 28, 1981 and February 18, 1982. Enclosed is our fifth interim report. We expect to submit our next report by July 19, 1982.

If you have any questions concerning this matter, please get in touch with R. H. Shell at FTS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY L

L. M. Mills, Manager Nuclear Licensing Enclosure oc:

Mr. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 Mr. James McFarland (Enclosure)

Senior Project Manager Babcock & Wilcox Company P.O. Box 1260 Lynchburg, Virginia 24505 ontalM2" 8206010 386 3

,g g ct7

[==l l

An Equal Opportunity Employer

e 4

o ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 SEISMIC QUALIFICATION OF B&W EQUIPMENT IN TVA PANELS NCR BLN BLP 8011 10 CFR 50.55(e)

FIFTH INTERIM REPCRT Description of Deficiency A number of B&W supplied instruments are intended for installation in TVA's free standing, open, local instrument panels. Because of imprecise specifications in a TVA procurement document, the instrumentation supplied by B&W has not been seismically qualified to a response spectra which is compatible with the response spectra for TVA local instrument panels.

The responsibility for this deficiency is TVA's.

A list of the instruments in question follows:

Type of Device Manu facturer Mfr ID No.

Diff. Pressure Transmitter Bailey Meter Co.

Type N1BQ8 N3BQ7 N3BQ8 N2BQ7 N2BQ8 Press Transmitter N3KS N2KS N1KS Rosemount 1152GP Dresser 1079 1188 Press Switch B400 Series Diff. Press Indicator ITT Barton Model 227 Diff. Press Switch ITT Barton Model 288A Electro / Pneumatic Converter Fisher Model 546 Interim Progress TVA is continuing to work both internally and with B&W in order to resolve the seismic problem. To date, of the 253 total B&W devices in question, all but 32 have been determined to be acceptable. For those 32, TVA has asked B&W to consider requalification of these devices to the higher "g" levels as part of the NUREG-0588 qualification program.

- -,