_. _

S GPU Nuclear g

Uhghg P.O. Box 388 Forked River, New Jersey 08731

  1. ,g w

609-693-6000 Wnter's Direct Dial Number:

May 21, 1982 Director Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Sir:

Subject:

Oyster Creek Nuclear Generating Station Docke t No. 50-219 Technical Specification Change Request No. 104 In accordance with 10 CFR 50.59 and 10 CFR 50.90, CPU Nuclear Corporation, operator of the Oyster Creek Nuclear Generating Station, Provisional Operating License No. DPR-16, requests a change to the license.

This Technical Specification change revises license DPR-16 to reflect that the replacement of all core spray spargers will occur during the Cycle 11 or later refueling outage vice the Cycle 10 refueling outage.

This Technical Specification Change Request has been reviewed and approved by the Director Oyster Creek Operat ons, the Plant Operations Review Committee, and an Independent Safety Review Group in accordance with Section 6.5 of the Oyster Creek Technical Specifications.

We have determined that the submittal is Class II per 10 CFR 107.22 and have enclosed a check for $1,200.00 pursuant to tha t section.

In the event that any comments or questions arise, please contact Mr. James Knubel of my staff at (201) 299-2264.

Very truly yours, j

I% ter B. Fredler fM Vke President and Director Cf ter Creek f/

wAbd:

/300.00 8 2 0 5 2 8 O E87,p GPU Nuclear is a part of the General Public Utilities System

General Public Utilities Nuclear Corporation Oyster Creek Nuclear Generating Station Docket No. 50-219 Provisional Operating License No. DPR-16 Applicant hereby requests the Commission to change the above captioned license as follows:

1.

Section to be Changed:

License No. DPR-16 2.

Extent of Change:

This license modification indicates that all core spray spargers will be replaced during or af ter the Cycle 11 refueling outage instead of the Cycle 10 refueling outage.

3.

Changes Requested:

The licensee requests that paragraph 2.C (7) of License No. DPR-16 Amendment No. 59 be changed to read as follows:

" Full inspections of the accessible surfaces and welds of both core spray spargers and repair assemblies at each refue.1',g outage will be perf onned. Comparisons of any indications to previous inspection indications will be made.

If additional or progressing indications are found, an evaluation of the spargers will be performed and documented by the licensee prior to resuming power operation.

If the analysis of inspection results indicates that the core spray sparger performance is unacceptable, the spargers will be repaired or replaced prior to resuming power operation."

4.

Discussion:

This Technical Specification Change Request confirms a presentation made l

by the upper management of GPU Nuclear Corporation to your staf f on December 11, 1981.

The meeting concerned the problems associated with our upcoming refueling outage including the requirement to replace all core spray spargers.

It was established that deferring this requirement might be acceptable provided that an inspection of the existing spargers be conducted during the next refueling outage.

The inspection should reveal that spray flow distribution and quantity of spray remains within specification and excessive cracking, beyond that which already exists, has not occurred.

(

f t

is t-s.

4

'l General Public Utilities Nuclear Corporation n

Provisional Operating License No. DPR-16 Technical Specification Change Request No. 10 4 Docket No. 50-219 t

Applicant submits by this Technical Specification Change Request No.

104 to the Oyster Creek Kuclear Generating Station Provisional Operating c

License a revision to Amendment No. 59 to that license. This change modifies the time requirements for replacement of all core spray spargers.

1 C

2 b_ _ d

~

By Peter B. Fiedler.

Vice President and Director q'-

Oyster Creek l

s Sworn to and subscribe'd to before me this c9. /

day of 7//a.c4 1982.

l Yt*

LLr M Y Notary Pub'lic 8[/

MKH:JL [t WAT foiArif PUB'.;C U *ai?i liR3M u, t.,

,fu

-. - al,IPs t

t A

r

+

\\

\\

4 u y

,r, UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION IN THE MATTER OF )

)

DOCKET NUMBER 50-219 GPU NUCLEAR CORP. )

CERTIFICATION OF SERVICE Th is is to certify that a copy of Technical Specification Change Request No. 104 for the Oyster Creek Nuclear Generating Station Technical S pe c i fica tion, filed with the U.S. Nuplear Regulatory Commission May 21, 1982, has this2'fM c[ap ef 7

, been served on the Mayor of on Lacey Township, Ocean County, New' Jersey, by deposit in the United States mail addressed as follows:

The Honorable Theodore Hut 1cr Mayor of Lacey Township 818 West Lacey Road Forked River, N.J.

08731 b

By Pe t e r B. Fiedler Vice President and Director Oyster Creek Dated:

May 21, 1982

GPU Nuclear Q g7 P O Box 388 Forked River. New Jersey 08731 609-693-6000 Writer's Direct Dial Number:

May 21, 1982 The Honorable 'Iheodore Hutler Mayor of Lacey Township 818 Wes t Lacey Road Forked River, N.J.

08731

Dear Mayor Hutler:

Enclosed is one copy of Technical Specification Change Request No.

104 for the Oyster Creek Nuclear Generating Station Operating License.

This document was filed with the United States Nuclear Regulatory Commission on May 21, 1982.

Very truly yours, I

/W,4o Peter B. Tledler Vice President und Director Oyster Creek PBF:JK:Ise Enclosure l

GPU Nuclear is a part of the General Puolic Utihties System