MAINE YANKEE ATOMIC POWER C0tiPANY EFFLUENT AND WASTE DISPOSAL SEMI-ANNUAL REPORT JULY-DECEf1BER 1980 8205170411

T EFFLUENT AND WASTE DISPOSAL SD11-ANNUAL REPORT JULY - DECD1BER 1980 FACILITY: MAINE YANKEE ATOMIC IOWER COMPANY LICENSEE: MAINE YANKEE ATOMIC POWER GD1PANY 1.

Regulatory Limits a.

Fission and activation gases:

10 CFR 20; Paragraph 20.106 b.

Iodines:

c.

Particulates, half lives 8 days d.

Liquid effluents:

-2.

Maxinum Permissible Concentrations a.

Fission and actuation gases:

10 CFR 20; App. B. Table 2 Col. 1 b.

Iodines:

c.

Particulates, half lives 8 days d.

Liquid effluents:

3.

Average Energy - Not Applicable 4.

Measurenent and Approximations of Radioactivity a.

Fission and activation gases:

Continuous discharge - vent stack samples are analyzed nonthly and the levels of activities determined are assuned to hold for the period between samples. The continuous vent stack monitor reading is used as a basis for increasing periodic sample frequency. Air ejector is sampled monthly and on any increase in continuous air ejector monitor reading.

Batch discharges - direct measurenent of waste gas holdup drtms are made before discharge. Containment vents and purges are analyzed by direct measurenent of the containment atmosphere at periodic intervals during the discharge.

b.

Continuous monitoring of primary vent stack iodines are made by weekly measurenents of an in-line charcoal filter.

Batch discharges - direct measurement of waste gas holdup drums before discharge, c.

Particulates - continuous monitoring of primary vent stack is made by weekly measurenent of an in-line particulate filter.

Batch discharges - direct measurement. of waste gas holdup drums before discharge.

i

4

?

- ~

d.

' Liquid Effluents Weekly sample of secondary systems liquid effluents for gross Beta-ganma, alpha,- tritiun, dissolved gases and gama emitting isotopes each batch release'.

~

Composite samples are made of secondary and p-imary systems liquid effluents for a quarterly analysis of strontium 90 and 89.

5.

Batch Release a.

Liquid 1.

Number of releases:

70 2.

Total time' for batch releases:

294 hrs 36 min 3.

Maxinum time for batch releases:

19 brs 40 min 4.

Average time for batch releases:

4 hrs 13 min

'5.

Mininum time for batch releases:

41 min 6.

Average stream f1m during periods of release of effluent into a f1 ming stream:

7.

Maximun gross release rate (uci/ml) 2.02E-8 b.

Gaseous 1.

Number of batch releases:

-18 2.

. Total time period.for batch releases:

194 hrs 34 min 3.

Maximum time period for a batch release:

55 brs 45 min.

4.

Average time period for a batch release:

10 hrs 49 min 5.

Mininum time for a batch release:

1 hr 5 min 6.

Maximun gross release rate (uci/sec):

9.34E2

6. -Abnormal Releases a.

Liquid e

There were no abnormal liquid releases during this' reporting pe iod.

b.

Gaseous

~

There were no abnormal gaseous releases during this reporting period.

The fo11 ming table is not attached since there was no'~ app $icable' release c.

during this reporting period.

~

Table 1C - Gaseous. Effluents, Ground Level Releases. '

M 4

n d'

- /,

\\

k e_

j RE! EASE OF WASTE GAS S1DRAGE DRINS BFFORE 60-DAY HOLDUP PERIOD Technical Specification 3.17B3 requires a special effluent report should the average holdup time of waste gas be less than 60 days.

We folloaing drums had a holdup time of less than 60 days during normal operations in the 2d half of 1980.

(In days)

Release No.

Decay Drum Dite Isolated Dite Reicased Ibidup Time Cu.Ft.

518 B

6/11/80 7/29/80 48 774 519 C

6/13/80 7/29/80 46 785 522 E

8/18/80 10/3/80 46 964

%e average holdup time for the second half of 1980, of all decay druns during normal operation, was' 58.6 days.

We decay drums released by Permit !b's. ' 518 and 519 contained gas generated during plant startep follueing the June shutdown. % eir early release was dictated by the need for additional storage volume.

Early release of the decay drun by Pennit No. 522 was required because of decreased available storage space resulting from leaking valves on two decay druns. As these two druns were unavailable for use, storage space was decreased by 407..

'shis reduced volume forced the early release of the drum.

(

g l.

,2 g

~.

4

- - -. _.. _ _.. ~

THE.LE 1H l

EFFLUENT AND NASTE DISPOSAL SEMIANNUAL REPORT 1980 GASEOUS EFFLUENTS-SUMMATION OF ALL RELEASES j

i-!

3RD 4TH EST.

! UNIT QUARTER !

OUARTER !

TOTAL

! ERROR % !

=____

_____________________________________________________________________ =-

l,

________e______________________________________________________________________

A.

FISSION & ACTIVATION GASES

!- 1.

TOTAL RELEASE CI

?

2.07E-01!

5.00E+01! 2.34E+00!

?

2.

AVERAGE PELEASE RATE FOR PERIOD

!UCI/SEC!

2,64E-02!

6.35E+00!----------

l!

3.

% OF TECH. SPECIFICATION LIMIT 2.42E-04!

5.72E-02!

t j _______________________________________________________________________________

B.

IODINES

_____________________________________________________________________===-===__

1.

TOTAL IODINE-131 CI 1.51E-06!

1.70E-06! 6.61E+00!

]

2.

AVERAGE RELEASE RATE FOR PERIOD

!UCI/SEC!

1.92E-07!

2.17E-07!----------

3.

% OF TECH. SPECIFICATION LIMIT 4.97E-06!

5.6EE-06!

4 4

i C.

PARTICULATES

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ = - -

)~!

1.

PARTICULATES WITH T 1/2 > 8 DAYS !

CI 1.88E-05!

9.62E-06! 6.61E+00!

2.

AVERAGE RELEASE RATE FOR PERIOD

!UCI/SEC!

2.40E-OS!

1.22E-06!----------

i !

3.

% OF TECH. SPECIFICATION LIMIT 9.08E-06!

8.75E-06!

4.

GROSS ALPHA RADIOACTIVITY CI 5.32E-08!

1.60E-07!

1

____________________________________________________________=

D.

TRITIUM

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ =.

=____________________________________________

i !

1.

TOTAL RELEASE CI 9.98E-01!

8.92E-01! 8.87E-01!

! 2 AVERAGE RELEASE RATE FOR PERIOD

!UCI/SEC!

1.27E-01!

1.13E-01!----------

8 3.

% OF TECH. SPECIFICATION LIMIT 1.64E-03!

1.47E-03!

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - = -

I s.

L 1

4 w

+

M '

J

is LL l t.

~

EFFLUENT AND NASTE DISPOSAL SEMIANNUAL REPORT 1980 GASCOUS EFFLUENTS-ELEVATED rdLEASE CONTINUOUS MODE BATCH MODE 3RD 4TH 3RD 4TH

!'NUCIDES RELEASED

! UNIT !

QUARTER OURRTER !

OUARTER !

QUAR 1ER !

1.

FISSION GASES KR-85 CI

! < 8.OOE-05!< 8.00E-05!

8.06E-02!

2.38E-02!

< 1.00E-07!< 1.00E-07!< 1.00E-07!< 1.00E-07!

KR-85M CI KR-87 CI

! < 3.00E-0?!< 3.00E-07!< 3.00E-07!< 3.00E-07!

KR-88 CI

! < 3.50E-07!< 3.50E-07!< 3.50E-07!< 3.50E-07!

< 3.50E-07!< 3.50E-07!

1.15E-01!

4.87E+01!

XE-137 8

CI XE-135 CI

! < 7.00E-07!< 7.00E-07!

7.21E-03!

1.12E+00!

< 5.OOE-07!< 5.00E-07!< 5.00E-07!< 5.00E-07!

XE-135M CI

< 1.70E-07!< 1.70E-07!< 1.70E-07!< 1.70E-07' XE-138 CI

< 1.00E-06!< 1.00E-06!

3.88E-03!

1.59E-01!

XE-131M CI XE-133M CI

! < 5. 00E-07 ! < 5. 00E-07 ! < 5, 00E'-07 ! < 5. 00E-07 !

< 1.70E-06!< 1.70E-05!< 1.70E-06!< 1.70E-06!

AR-41 CI UNIDENTIFIED CI O.00E-01!

0.00E-01!

O.00E-01!

0.00E-01!

TOTAL FOR PERIOD CI O.00E-01!

0.00E-01!

2.07E-01!

5.00E+01!

_=---------------------------------------


.-----------=.

f 2.

IODINES I-131 CI 1.51E-06!

1.70E-06!< 9.60E-15!< 9.60E-15!

< 5.50E-13!< 5.50E-13!,< 5.50E-13!< 5.50E-13!

l !

I-132 CI I-133 CI

! < 4.60E-14!< 4.60E-14!< 4.6AE-14!< 4.60E-14!

I-134 CI

! < 1.60E-12!< 1.60E-12!< 1.60E-12!< 1.60E-12!

< 4.50E-13!< 4.50E-13!< 4.50E-13!< 4.50E-13!

I-135 CI TOTAL FOR PERIOD CI 1.51E-06!

1.70E-06!

0.00E-01!

O.00E-01!

3.

PARTICULATES

- - _ = = = - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

SP-89 CI 9.44E-07!

5.62E-07!< 1.00E-16!< 1.00E-16!

SR-90 CI 2.15E-08!< 4.70E-18!< 4.70E-18!< 4.70E-18!

CS-134 CI

! < 9.70E-15!< 9.70E-15!< 9.70E-15!< 9.70E-15!

CS-137 CI 3.42E-06!

2.76E-06!< 1.10E-14!< 1.10E-14!

BA-140 CI

! C 3.60E-14!< 3.60E-14!< 3.60E-14!< 3.60E-14!

OTHERS CO-58 CI 1.09E-05!

4.21E-07!< 8.90E-15!< 8.90E-15!

CO-60 CI 3.44E-06!

5.70E-06!< 1.40E-14!< 1.40E-14!

CI 0.00E-01!

0.00E-01!

0.00E-01!

O.00E-01!

CI

~!

0.00E-01!

0.00E-01!

0.00E-01!

0.00E-01!

CI O.OOE-01!

O.00E-01!

0.00E-01!

O.00E-01!

CI 0.00E-01!

0.00E-01!

0.00E-01!

0.00E-01!

CI 0.00E-01!

O.00E-01!

O.00E-01!

0.00E-01!

CI O.00E-01!

0.00E-01!

O.00E-01!

O.00E-01!

CI 0.00E-01!

0.00E-01!

0.00E-01!

0.00E-01!

UNIDENTIFIED CI O.00E-01!

0.00E-01!

O.00E-01!

O.00E-01!

_---------------------------~.-------_

= -----------

a

TABLE 2A EFFLUENT AtJD HASTE DISPOSAL SEMIANflUAL REPORT 1980 LIOUID EFFLUENTS--SUMMATIOtJ OF ALL RELEASES

+------ +-------_- +--------- +_------------- +

e i

.i e

i UtJIT !

3RD 4TH EST. TOTAL i

! OUARTER

! QUARTER ERROR %

+----_-_+_--_-_--- +--------- +-------------- +

l A.

FISSION AtJD ACTIVATIOra PRODUCTS +

! 1.

TOTAL RELEASE CI

! 1.55E-02 ! 1.57E-02 ! 7.75E-01

! 2.

AVERAGE DILUTED COtJCEtJTRATIOtJ DURItJG PERIOD

! UCI/ML! 8.07E-11 ! 8.29E-11 !

ir-------------------

c.----------------------------------

! 3.

% APPLICABLE LIMIT

! 1.09E-03 ! 8.20E-04 !

B.

TRITIUM

! 1.

TOTAL RELEASE CI

! 4.67E+01 ! 8.90E+01 ! 2.25E-01 l ! 2.

i AVERAGE DILUTED CONCEtJTRATIOtJ DURING PERIOD

! UCI/ML! 2.43E-07 ! 4.71E-07 !

! 3.

% APPLICABLE LIMIT

! 8.11E-03 ! 1.57E-02 !

l l-------------------------------------------------------

C.

DISSOLVED AND EtJTRAItJED GASES l ! 1.

TOTAL RELEASE CI

' 2.92E-03 ! 1.63E-03 3 3.74E+00 l------------------------!

i ! 2.

AVERAGE DILUTED I

CONCENTRATIOtJ I

i !

DURIfJG PERIOD

! UCI/ML! 1.52E-11 ! 8.61E-12 !


_ = _==-----------------------------

! 3.

% RPPLICABLE LIMIT

! 7.59E-06 4.31E-06 !

D.

GROSS ALPHA RADIOACTIVITY

==

! 1.

TOTAL RELEASE CI

! 1.98E-07 ! 2.06E-07 ! 8.54E+01 I k. VbLUMb bF BASTE

!LITdRb 1.b4k+b7 ! 1[96E+b7 I 1. Odd +b1 I

-=-----_---

! F.

VOLUME OF DILUTION

! LITERS ! 1.92E+11 ! 1.89E+11 ! 1.00E+01

- - = =

0 TOTAL RELEASE EXCLUDIfJG TR47IUM, GASES, Af4D AND ALPHA.

J EFFLUEtiT AND NASTE DISPOSAL SEMIANNUAL REPORT 1980 LIQUID EFFLUENTS COtlTINUOUS MODE BATCH MODE

! NUCLIDES PELEASED

! UNIT

! OUARTER-3 ! QUARTER-4 ! QUARTER-3 ! QUARTER-4!

SR-89 CI

!<1.00E-09

!<1.00E-09

!<1.00E-08

!<1.00E-08 !

SR-90 CI

!<1.00E-09

!<1.00E-09

!<1.00E-08

!<1.00E-08 !

CS-134 8

CI

' 9.52E-05

! 2.96E-04

! 2.04E-03

! 1.62E-03 !

CS-137 CI

! 2.31E-04

! 2.62E-04

! 6.01E-03

! 7.02E-03 !

I-131 CI

'<1.00E-08

!<1.00E-08

! 4.32E-04

! 2.05E-04 !

CO-58 CI

! 2.49E-04

! 1.01E-05

! 5.32E-03

! 3.11E-03 !

FE-59 CI

!<1.00E-Q7

!<1.00E-07

!<1.00E-06

!<1.00E-06 !

=-.

ZN-65 CI

!<9.00E-08

!<9.00E-08

!<9.00E-07

!<9.OOE-07 !

MN-54 CI

!<5.00E-08

! 5.04E-06

! 6.53E-05

!<5.00E-07 !

=___.

CR-51 CI

!<3.00E-07

!<3.00E-07

!<3.00E-06

!<3.00E-06 !

=-.

3R-95 CI

!<8.00E-08

!<8.00E-08

!<8.00E-07

!<8.00E-07 !

l '

MO-99 CI

! 6.56E-06

!<4.00E-08

!<4.0GE-07

!<4.00E-07 !

CI

'<4.00E-08

!<4.00E-08

!<4.00E-07

!<4.OGE-07 !

TC-99M CI

!<2.00E-07

!<P. 60E-07

!<2.00E-06

!<2.00E-06 !

BA-140 CE-141 CI

!<4.00E-07

!<4.00E-07

!<4.00E-07

!<4.00E-07 !

OTHER I-133 CI

!<4.00E-07

!<4.00E-07

! 8.65E-06

! 1.22E-94 !

KR-88 CI

!<2.00E-07

!<2.00E-08

!<2.00E-06

! 2.01E-05 !


__--_-------_-- --------------_-----__--_------_-------- _= --

-- =

F-18 CI

!<4.00E-08

!<4.00E-08

!<4.00E-07

! 4.73E-06 !

CI

!<0.00E-01

!<0.00E-01

!<0.00E-01

!<0.00E-01 !

UNIDEt4TIFIED CI

! 0.00E-01

! 0.00E-01

! 0.00E-01

! 0.00E-01 !

TOTAL FOR PERIOD CI

! 1.06E-03

! 2.44E-03

! 1.44E-02

! 1.32E-02 !

=-- _-------- ---------------

=

_ - - - _ _ - _ = - - - -

XE-133 CI

!<1.00E-07

!<1.00E-07

! 2.63E-03

! 1.34E-03 !

XE-135 CI

'<6.00E-06

!<6.00E-06

! 2.84E-04

! 2.92E-04 !

--___-_____-_---_-----------_-_------ -- --------------_-_------_---=

f1OTE: - ACTIVITIES OP -ZR AND-BA-1-40-INCLUDE-tYJf4TRIBUTIONS OF-DAUGHTERS. ~ ---

NOTE: LESS.THAN <<> VALUES ARE MI?lIMUM DETECTABLE ACTIVITIES I?J UCI/CC.

L s

v l,

TABLE 3 EFFLUENT AND WASTE DISPO. CAL SE!!IANNUAL REPORT SOLID WASTE AND IRRADIATED FUEL SHIPMENTS 1

A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL GR DISPOSAL (Not irradiated fuel) 6-month Est. Total

1. Type of waste Unit Period Error,.

l

a. Spent resins, filter sludges, evaporator m3 1.34 E + O2 3.0 E + 01 bottoms, etc.

Ci 6.66 E + O2

b. Dry compressible waste, contaminated m3 6.42 E + 01 3.0 E + 01 eouip, etc.

C1 4.38 E - 01 3

c. Irradiated components, control m

rods, etc.

Ci m3

d. Other (describe)

Ci

2. Estimate of major nuclide composition (by type of waste).

a.

CS-137 4.0 F + 01 C0-58 4.0 E + 01 CO-60 1.0 E + 01 CS-134 1.0 E + 01 b.

CS-137 3.0 E + 01 CO-58 3.0 E + 01 CO-60 3.0 E + 01 CS-134 1.0 E + 01 l

t,

[

e.

5 t

l i

d.

l l

3'. Solid Waste Disposition Number of Shipments Mode of Transportation Destination 21 Truck

,Chemt Nuclear System Barnwell, S. C.

1 Truck

'Juclear Eng. Co.

l B. IRRADIATED FUEL SHIPMENTS (Disposition)

.,'..Beatty, Nev.

i I

Number of Shipments Mode of Transportation Destination h

e l

e i

I e

6,

-