f^

0 44 is

% gy l$$

)}

m g47 C

p Power cu N

""$'p'r'i1"5, 1982

  1. 3F-0432-02 File: 3-0-26 Dr. Roger J. Mattson, Director Division of Systems Integration Of fice of Nuclear Reactor Regu!ation U.S. Nuclear Regulatory Commission Washington, D.C. 20555

Subject:

Crystal River Unit 3 Docket No. 50-302 Operating License No. DPR-72 NUREG-0737, item II.F.2 Reactor Coolant System Water Level Measurement

Dear Dr. Mattson:

In your meeting of February 17 and 18,1982, you requested that each utility forward to you an estimate of the cost, time frame, and radiation exposure entailed in the installation of a reactor coolant system (RCS) water level measurement system. Florida Power Corporation (FPC) has developed such estimates for the B&W designed Hot Leg Level Measurement System (HLLMS). This includes both a narrow range (upper portion of the hot leg) and a wide range (reactor hot leg nozzle to top of the hot leg) subsystem. It does not include a reactor vessel head water level measurement subsystem. The estimates are as f

  • lows:

Narrow Range Wide Range Wide and Narrow Subsystem Subsystem Range Subsystems Cost

$1.3 million

$1.4 million

$1.8 million Installation Fall 1984 Fall 1987 Fall 1987 Radiation Exposure 5 Man-Rem 18-20 Man-Rem 23-25 Man-Rem if you require any clarification or need further information, please contact this of fice.

Very truly yours, A

David G. Mardis

(

/

h Acting Manager 5

Nuclear Licensing

/

/$

cc:

Mr. 3. P. O'Reilly, Regional Administrator Of fice of Inspection & Enforcement U.S. Nuclear Regulatory Commission 101 Marietta Street N.W., Suite 3100 Atlanta, GA 30303 8204090251 820405 PDR ADOCK 05000302 P

PDR General Of fice rot inirteourin street soutn. P O Box 14042, st Petersburg Florida 33733 813 - 866-5151