Forwards IE Safeguards Insp Rept 70-0036/82-02 on 820308-12 & Notice of Violation
ML20050B838
Person / Time
Site: 07000036
Issue date: 03/30/1982
From: Roy G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Lichtenberger
ABB COMBUSTION ENGINEERING NUCLEAR FUEL (FORMERLY
Shared Package
ML20050B839 List:
References
NUDOCS 8204070474
Download: ML20050B838 (2)


Text

.

!E HQ RLE GOPY c

MAR 3 01T2 N

[

g

/!'

RECEIVED Docket No. 70-36(DETP) 4 2

APR 0 G 1982 > ;

Combi.stion Engineering, Inc.

Oy u p,mmu m ATIN:

Mr. H. V. Lichtenberger s'm wmu n S

Vice President cg Manufacturing Nuclear Power Systems 4'Ii Windsor, CT 06095 Gentlemen:

This refers to the routine safeguards inspection conducted by A. G. Finley of this office and J. Blaylock, Safeguards Branch, Division of Fuel Facilities, Materials and Safeguards, IE on March 8-12, 1982, of activities at. Combustion Engineering, Hematite Plant, authorized by License No. SNM-33 and to the discussion of our findings with Mr. J. Rode, Plant Manager, and~

members of his staff at the conclusion of the inspection.

The enclosed copy of our inspection report identifies areas examined during the inspection. Within these areas, the inspection consisted of a selective examination of procedures and representative records, observations, and in-terviews with personnel.

'During this inspection, certain of your activities appeared to be in non-compliance with NRC requirements, as specified in the enclosed Appendix.

A written response, submitted under oath or affirmation, is. required.

Areas examined during this inspection concern a subject matter which is exempt from disclosure according to Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations. Consequently, the enclosure to this letter, our report of this inspection, and your response to the noncompliance identified in the enclosure to this letter will not be placed in the Public Document Room. Therefore, your state-ment of corrective action regarding the noncompliance identified in the enclosure should be submitted as a separate enclosure to your transmittal letter.

The responses directed by this letter (and the accompanying Notice) are not subject to the clearance procedures of the Office of Management and Budget as required by the Paperwork Reduction Act of 1980, PL 96-511.

'1>ria:

ffDS S204070474 820330 ATTACHME!fr CONTAINS pDR ADOCM 03000036 CFR 2.790(d) INFORMATION

/[

C PDR

Combustion Engineering, Inc.

2 FAR 3 0 E02 We will gladly discuss'any questions you have concerning this inspection.

Sincerely,

" Original signed by, Gin V. by",

G. W. Roy, Acting Chief Technical Inspection Branch

Enclosures:

1.

Appendix, Notice of Violation

- 2.

Inspection Report No. 70-36/82-02(DETP)

(2.790(d) Information) cc w/encls:

J. A. Rode, Plant Manager DMB/ Document Control Desk (RIDS)

I RIII RII RIII[b

[8 RIII 8kI ll{

Finley/so reed RT5gway

- oy 3/22/82 f

? l')

ATTACHMENT CONTAINS 10 CFR 2.790(d) INFORMATION