a SOUTH CAROLINA ELECTRIC a GAS COMPANY post orrics som re.

CotuMaia, south CARouMA 29288 T. C. Nic Mots, J m.

va rm

.r... o. cmmm March 31, 1982

,e u..o..

no..

t-CO 9

Mr. Ilarold R. Denton, Director s

3

[4ECU t

Office of Nuclear Reactor Regulation

'p

~~

U. S. Nuclear Regulatory Cmmission Washington, D. C. 20555 APR 051987p EMgyMY V

Subject:

Virgil C. Stamer Nuclear Station as Docket No. 50/395 g

Technical Specifications jN

Dear Mr. Denton:

Attached are miscellaneous changes to the Proof and Review Copy of the Technical Specifications for the Virgil C. Stminer Nuclear Station.

'Ihe following is a brief explanation of the reasons for the requested changes:

PAGE EXPIRIATIOJ 3/4 1-18 OIANNEL FUNCTIONAL TEST is no longer defined in Section 1.0 and therefore should be changed to ANAIOG GIANNEL OPERATIORL TEST.

I 3/4 3-29

'Ihe response times of the Engineered Safety Features thru in Table 3.3-5 were reviewed. As a result, several 3/4 3-4 changes were made to e arify or correct the response

~

times. Notes 4 and L m re added to the Table l

Notation to describe the time delays for those Engineering Safety Features Systm s that are not associated with the operation of the charging or RHR pumps. Also, the clarification that the respanse l

times are based on undervoltage was added.

3/4 3-51 Tables 3.3-8 and 4.3-5 have been revised to reflect the and actual meteorological instnmentation at the Virgil C.

l 3/4 3-52 Stamer Nuclear Station.

3/4 6-7

'Ihe Surveillance Requirments for this Specification have been revised to provide a larger ntmber of locations for measuring contaiment air tmperature.

'Ihe arithmetical average of these tmperatures will better represent the contaiment average air tmperature.

i 8204060000 820331 DR ADOCK 05000395 08 PDR 1

4 1

ht

{k I

Mr. Harold R. Denton March 31, 1982 Page 'IWo Please contact Mr. Shealy if you have any questims.

Very truly yours, ff db

. C. Nich ls, Jr.

IDS:'KN, jr: jr

/*#

Attachments ces: Messrs. V. C. Suniter (w/o attach.)

G. H. Fischer (w/o attach.)

H. N. Cyrus (w/o attach.)

T. C. Nichols, Jr.

H. T. Babb W. A. Williams, Jr.

M. B. Whitaker, Jr.

D. A. Naunan O. S. Bradham L. D. Shealy.

-R. B. Clary W. R. Baehr M. N. Brome A. R. Koon G. J. Braddick J. L. Skolds J. B. Knotts, Jr.

B. A. Bursey M. J. Virgilio C. L. Ligon (NSBC)

J. C. Ruoff J. P. O'Reilly J. R. Cbokinham W. F. Kane NPCF File 4

I

-~

-..