ML20045G671

From kanterella
Jump to navigation Jump to search

Forwards Safety Evaluation Granting Licensee Relief from Certain Requirements of ASME Boiler & Pressure Vessel Code, Section Xi.Concludes That Util May Invoke Code Case N-416 & W/Addl Exams,Structural Integrity of Sys Ensured
ML20045G671
Person / Time
Site: Haddam Neck File:Connecticut Yankee Atomic Power Co icon.png
Issue date: 07/09/1993
From: Stolz J
Office of Nuclear Reactor Regulation
To: Opeka J
CONNECTICUT YANKEE ATOMIC POWER CO., NORTHEAST NUCLEAR ENERGY CO.
Shared Package
ML20045G672 List:
References
GL-90-05, GL-90-5, TAC-M86237, NUDOCS 9307150032
Download: ML20045G671 (4)


Text

-

DMM k_ct

'p y

h

?*,

i i+(

E UNITED STATES i

NUCLEAR REGULATORY COMMISSION

\\.....,8 W ASHINGTON, D.C. 2055b0001 July 9, 1993 Docket No. 50-213 Mr. John F. Opeka Executive Vice President, Nuclear l

Connecticut Yankee Atomic Power Company Northeast Nuclear Energy Company Post Office Box 270 1

Hartford, Connecticut 06141-0270

Dear Mr. Opeka:

SUBJECT:

HADDAM NECK PLANT - REQUESTS FOR RELIEF FROM SECTION XI CODE REQUIREMENTS FOR THE HADDAM NECK PLANT (TAC M86237)

By letter dated April 8, 1993, Connecticut Yankee Atomic Power Company l

(CYAPC0) submitted a request for relief from certain requirements of the ASME l

Boiler and Pressure Vessel Code,Section XI (Code).

The relief request was l

for a temporary noncode repair for a leak in the elbow of the service water system piping to the emergency diesel generators. CYAPC0 stated that the Code repair would be completed during the upcoming refueling outage.

By letter l

dated June 25, 1993, CYAPC0 informed the staff that the Code repair was completed and requested to withdraw the relief request associated with the l

noncode temporary repair. The staff has reviewed the temporary repair request i

and withdrawal and concluded CYAPCO's submittals are consistent with Generic Letter 90-05. As the weld has been repaired, the staff agrees the relief request may be withdrawn.

By [[letter::B14466, Suppls 930408 Request for Relief from ASME Section XI Requirements,Per GL 90-05,to Make Interim Repairs to Two Pinhole Leaks in Svc Water Sys Elbow Weld.Leaking Weld on EDG B Svc Water Inlet Line Will Be Replaced W/New Elbow|letter dated May 21, 1993]], as supplemented by letter dated June 1, 1993, CYAPC0 submitted a relief request concerning the permanent repair and the replacement of additional service water piping necessitated by this repair.

l Upon completion of a Code repair,Section XI requires an elevated pressure test and visual examination to be performed.

CYAPC0 has requested the use of an alternative to the ASME Boiler and Pressure Vessel Code,Section XI (1983 edition with summer addenda) requirements pursuant to 10 CFR 50.55a(a)(3)(i).

Specifically, CYAPC0 requested the use of Code Case N-416 as an alternative to the hydrostatic pressure tests that are required after completion of the repairs to the Class 3 service water piping.

The relief request is necessary.

because while Code Case N-416 has been approved for Class 2 piping, CYAPC0 has requested to apply it to Class 3 piping.

The staff has reviewed the relief request dated May 21, 1993, and concluded CYAPCO' submittal is consistent with 10 CFR 50.55a(a)(3)(i).

CYAPC0 has demonstrated that the proposed alternative will provide an acceptable level of quality and safety.

Therefore, the staff concludes that CYAPC0 may invoke Code Case N-416 and with the additional examinations, the structural integrity of the system is ensured.

However, by invoking Code Case, N-416 CYAPC0 will not be able to use Code Case N-498, " Alternative Rules for 10-Year Hydrostatic Pressure Testing for Class 1 and 2 Systems," in 1997.

3N09 fLh$ N. b Y

93071500 2 DR ADOCK 0500 3-

July 9, 1993 Mr. John F. Opeka A copy of the Safety Evaluation is enclosed. If you have any questions please i

call Alan Wang at (301)504-1445.

Sincerely, Original signed by Ronald Hernan 4

for:

John F. Stolz, Director Project Directorate I-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/ enclosure:

See next page DISTRIBUTION:

l Docket File-l NRC & Local PDRs l

PDI-4 Plant l

TMurley/FMiraglia JPartlow ERossi JLieberman SVarga JCalvo JStolz l

SNorris AWang OGC EJordan GHill (2)

ACRS (10)

OPA OC/LFDCB VMcCree LDoerflein DNaujock

. Al.

,h[

OFFICE LA:PDI-4 PM:PDI-4 D:PDI-4 /)

OGC NAME St AWang:bh6W JStolzhllk Nbh

'/ / / /93 7/f/93

//

6 DATE 7/ l /93

'l / I /93 0FFICIAL RECORD COPY I

Document Name:

G:\\ WANG \\RRN16 l

l

,,.<,e

..w

o Mr. John F. Opeka July 9, 1993 A copy of the Safety Evaluation is enclosed. If you have any questions please call Alan Wang at (301)504-1445.

Sincerely, G4 y

i John F. Stolz, Director

~' -

Project Directorate I-4 Division of Reactor Projects - I/II Office of Nuclear Reactor Regulation

Enclosure:

Safety Evaluation cc w/ enclosure:

See next page i

1 l

l l

l l

l

l Mr. John F. Opeka Haddam Neck Plant Northeast Nuclear Energy Company cc:

Gerald Garfield, Esquire R. M. Kacich, Director Day, Berry and Howard Nuclear Licensing Counselors at Law Northeast Utilities Service Company City Place Post Office Box 270 Hartford, Connecticut 06103-3499 Hartford, Connecticut 06141-0270 W. D. Romberg, Vice President S. E. Scace, Vice President Nuclear Operations Services Millstone Nuclear Power Station Northeast Utilities Service Company Northeast Nuclear Energy Company Post Office Box 270 Post Office Box 128 Hartford, Connecticut 06141-0270 Waterford, Connecticut 06385 Kevin McCarthy, Director Regional Administrator Radiation Control Unit Region I Department of Environmental Protection U.S. Nuclear Regulatory Commission 165 Capitol Building 475 Allendale Road Hartford, Connecticut 06106 King of Prussia, Pennsylvania 19406 Allan Johanson, Assistant Director Board of Selectmen Office of Policy and Management Town Office Building Policy Development and Planning Division Haddam, Connecticut 06438 80 Washington Street i

l Hartford, Connecticut 06106 Resident Inspector Haddam Neck Plant i

J. P. Stetz, Vice President c/o U.S. Nuclear Regulatory Commission Haddam Neck Plant 361 Injun Hollow Road Connecticut Yankee Atomic Power Company East Hampton, Connecticut 06424-3099 362 Injun Hollow Road East Hampton, Connecticut 06424-3099 Nicholas S. Reynolds Winston & Strawn D. J. Ray 1400 L Street, NW l

Haddam Neck Unit Director Washington, DC 20005-3502 Connecticut Yankee Atomic Power Company 362 Injun Hollow Road East Hampton, Connecticut 06424-3099 l

l G. H. Bouchard, Director Nuclear Quality Services Northeast Utilities Service Company Post Office Box 270 Hartford, Connecticut 06141-0270 l

I 1

-