_ ')

4*-

i 1

l i

Vogtle Electric Generating Plant Request to Revise Technical Specifications Semiannual Radioactive Effluent Release Report i

ELoposed Technical Specification Changes

)

9307130159 930702 G(

i PDR ADOCK 05000424 M

P PDR f

I 4

3 RADI0 ACTIVE EFFLUENTS

)

LIOUID HOLOUP TANKS LIMITING CONDITION FOR OPERATION

.)

3.11.1.4 The quantity of radioactive material contained in each outside temporary tank shall be limited to less than or equal to 10 curies, excluding tritium and dissolved or entrained noble gases.

APPLICABILITY: At all times.

I ACTION:

a.

With the quantity of radioactive material in any of the outside temporary tanks exceeding the above limit, immediately suspend all additions of radioactive material to the tank, within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> reduce the tank contents to within the limit, and describe the events leading to this condition in the next-Semiannual Radioactive Effluent ReleaseReport,pursuanttoSpecification6.8.1.I!N Annul s s s, b.

The provisions of Specification 3.0.3 are not applicable.

l SURVEILLANCE RE0VIREMENTS 4.11.1.4 The quantity of radioactive material contained in each of the above listed tanks shall be determined to be within the above limit by analyzing a representative sample of either the tank's contents at least once per 7 days when radioactive materials are being added to the tank or each batch of radio-active material prior to its addition to the tank.

)

)

V0GTLE UNITS - 1 & 2 3/4 11-4 Amendment No. 59 (Unit 1)