PY-CEI/NRR-1663 L Page 1 of 1 RESTATEMENT OF THE SUPPRESSION POOL AND CONTAINMENT AIR TEMPERATURE TECHNICAL SPECIFICATION AND BASES CHANGES Page Specification and Description of Changes 3.6.1.7 - Primary Containment Average Air Temperature 3/4 6-11 In the LCO and the Action, increase the primary containment average air temperature value from 90 to 95'F.

3.6.3.1 - Depressurization Systems:

Suppression Pool 3/4 6-22 In the LCO, item 3.6.3.1.b, increase the maximum average suppression pool temperature from 90 to 95'F.

In Actions 3.6.3.1.b, 3.6.3.1.b.1 and 3.6.3.1.b.2.a, increase the maximum average suppression pool temperature from 90 to 95'F.

3/4 6-23 In Surveillance Requirements 4.6.3.1.b, 4.6.3.1.b.2, and 4.6.3.1.b.3 and 4.6.3.1.c, increase the maximum average 3/4 6-24 suppression pool temperature from 90 to 95'F.

The above Specification changes are identical to those proposed in

', Page 2, of letter PY-CEI/NRR-1510 L.

Only the temperature related changes for the Containment Air and Suppression Pool Water are listed above.

l 9306290024 930621 PDR ADOCK 05000440 P

PDR

PY-CEI/NRR-1663 L Table 1 Page 1 of 4 SECTIONS OF THE CONTAINMENT RESPONSE ANALYSIS TECHNICAL SPECIFICATION AMENDMENT REQUEST THAT ARE APPLICABLE TO AN INCREASE IN CONTAINMENT AIR AND SUPPRESSION POOL VATER TEMPERATURE Section of Containment Response Analysis Letter PY-CEI/NRR-1510L Applicability Clarifications Cover Letter Yes Limited to suppression pool (SP) and containment air temperature related changes.

Introduction Yes Summary Yes References to upper containment pool (UCP) changes, SP level changes, and peak accident pressure (P ) changes are not applicable.

Refer to the listing of the TS changes in this letter (Attachment 1, page 1 of 1).

Reasons for the Change Yes

Background

Yes Safety Analysis - Part A:

Yes References to UCP changes, SP level and peak Containment Response Analysis P, changes are not applicable.

A.1 Inputs to the Containment Yes Response Analysis Increased SP Vater &

Yes Containment Air Temperature Expandad SP Water Level No Operating Band Dryvell-to-Containment dp No Assumed Higher Rx Power Level Yes Increases conservatism.

9 D

PY-CEI/NRR-1663 L i

Table 1 Page 2 of 4 UCP Vater Level and Temperature No A.2 Short-Term Containment Response Yes Increased conservatism.

i A.3 Long-Term (LT) Containment Yes Increased conservatism.

Response

Event Response for the LT Yes Increased conservatism.

Analysis SP Dravdown Event Analysis No A.4 Dryvell Negative Pressure Yes

Response

A.5 Containment Leakage Testing No Safety Analysis - Part B:

Yes References to the UCP changes are not Contai.. ment Structural and applicable.

Hydrodynamic Response B.1 S t ruc tu ra.1 Design Review-Yes B.2 LOCA Related Containment Loads Yes References to SP level changes are'not applicable.

1. LOCA Bubble & Pool Svell Yes References to SP level changes are not Loads applicable.
2. Condensation Oscillation-Yes References to SP level change's are'not

[

Loads applicable.

t

3. Chugging Yes

. References to SP level changes are not applicable.

B.3 SRV Operational Loads Yes References to SP level changes are not l

applicable.

D m

a

=

__=i,-

-.--e.

+-

ue m-

i PY-CEI/NRR-1663 L Table 1 Page 3 of 4

1. Air-Clearing Loads Yes References to SP level changes are not applicable.
2. Steam Condensation Loads Yes References to SP level changes and UCP changes are not applicable.

Safety Analysis - Part C:

Yes Plant-Specific Considerations C.1 NPSH Yes References to SP level changes are not applicable.

C.2 ECCS Pump Seal Integrity Yes C.3 Core. cooling capability Yes C.4 Impact on the E0Ps Yes References to SP level changes and UCP changes are not applicable.

C.5 SB0 Yes References to SP level changes and UCP changes are not applicable.

i C.6 ATVS Yes References to SP level changes and UCP changes are not anplicable.

C.7 Fire Hazards Analysis Yes C.8 Submergence of SP Temperature No SP vater levels are unchanged.

Monitors i

4 C.9 EQ Yes 1

C.10 Hydrogen Control Analysis Yes S'ummary of All the Parts Yes References to UCP changes,.SP level changes, Conclusions and peak P changes in-the summary paragraph a

are not applicable.

4 e

4 7

n

._-._.__...__,._.m

_.m..

PY-CEI/NRR-1663 L Table 1 Page 4 of 4 Significant Hazards Consideration Yes I.

Containment Response Input, Yes References to UCP changes, SP level Structural and Plant-Specific level changes, and peak P, changes are not Considerations applicable.

II.

Containment Response No Analysis - P 3

III. Reduction in UCP Depth -

No Refueling IV.

Editorial Changes No Environmental Consideratior.

Yes References Yes Table 1: Containment Response Yes References to UCP changes, SP level changes Input Parameters and Event Results and peak P changes are not applicable.

Figure 1: SP. Level Adjustment No Graph Attachment.2: Listing of the Yes Use the portions of the listing for Proposed TS and Bases Changes temperature changes to Specifications 3.6.1.7 and 3.6.3.1 (pages 3/4 6-11, 3/4 6-22, 3/4 6-23, and 3/4 6-24).

- : TS Mark-up Pages Yes Only revising Specifications 3.6.1.7 and 3.6.3.1 to reflect increased temperatures.

l GE Containment Response Analysis Yes Full capability of analysis not utilized Report through issuance of this limited scope amendment.

I 4