Amends 15 & 1 to Licenses NPF-87 & NPF-89,respectively Changing TSs to Reduce Frequency of Turbine Valve Testing from Every 14 Days to Every 6 Wks & to Reduce Frequency of Direct Observation of Operation of Valves
ML20044H010
Person / Time
Site: Comanche Peak  
(NPF-87-A-015, NPF-87-A-15, NPF-89-A-001, NPF-89-A-1)
Issue date: 05/21/1993
From: Black S
Office of Nuclear Reactor Regulation
To:
Shared Package
ML20044H011 List:
References
NUDOCS 9306070211
Download: ML20044H010 (7)


Text

l

~

"N' j

t UNITED STATES '

l j

j j

NUCLEAR RESULATORY C3MMISSION i

2 WASHifeGToN. D.C. M i

4 11165 UTILITIES ELECTRIC COMPANY. ET AL.*

i COMANCHE PEAK STEAM ELECTRIC STATIM. MIT 1 I

j DOCKET NO. 50-445 i

AMENDMENT TO FACILITY OPERATING LICENSE

)

Amendment No. 15 License No. NPF-87 i

]

1.

The Nuclear Regulatory Commission (the Commission) has found that:

l A.

The.applicatiens for amendment by Texas Utilities Electric Company l

t i

(TV Electric) acting for itself and as agent for Texas Municipal Power Agency (licensees) dated November 10, 1992, as supplemented by letter dated March 17, 1993, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended. (the Act),

and the Comission's rules and regulations set forth in 10 CFR i

l Chapter I; j

B.

The facility will operate in confomity with the application, as l

amended, the provisions of the Act, and the rules and regulations of

^

the Comission; l

C.

There is reasonable assurance:

(i) that the activ_ities authorized j

by this amendment can be conducted without endangering the health j

and safety of the public, and (ii) that such activities will be conducted in compliance with the Commission's regulations; D.

The issuance of this license amendment will not be inimical to the common defense and security or to the health and safety of the public; and i

i E.

The issuance of this amendment is in accordance with'10 CFR Part 51 of the Commission's regulations and all-applicable requirements have been satisfied.

1

  • The current owners of the Comanche Peak Steam Electric Station are: Texas Utilities Electric Company and Texas Municipal Power Agency. Transfer.of ownership from Texas Municipal Power Agency to Texas Utilities Electric

,i Company was previously authorized by Amendment No. 9 to Construction Permit CPPR-126 on August 25, 1988 to take place in.10 installments as set forth in the Agreement attached to the application for Amendment dated March 4, 1988.

At the completion thereof, Texas Municipal Power Agency will no longer retain any ownership interest.

i I

9306070211 930521 PDR ADOCK 05000445 P

PDR

. 2.

Accordingly, the license-is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-87 is hereby amended to read as follows:

2.

Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No.15, and the Environmental Protection Plan contained in Appendix B, both of which are attached hereto, are hereby incorporated in the license.

The licensee shall_ operate the 1

facility in accordance with the Technical Specifications and the

]

Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance to be t

implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMISSION

/M Suzanne E. Black, Director Project Directorate IV-2 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation

Attachment:

Changes to the Technical Specifications Date of Issuance:

May 21, 1993

f k

UNITED STATES j

}

NUCLEAR REGULATORY COMMISSIDN WASHINGTON. D.C. M

%,...../

TEXAS UTILITIES ELECTRIC COMPANY. ET AL.*

COMANCHE PEAK STEAM ELECTRIC STATION. L511T 2 00CKET M. 50-446 AMENOMENT TO FACILITY OPERATING LICENSE Amendment No. 1 License No. NPF-89 1.

The Nuclear. Regulatory Commission ~(the Commission) has found that:

A.

The applications for' amendment by Texas Utilities Electric Company

~

(TV Electric) acting for itself and as agent for Texas Municipal Power Agency (licensees) dated November 10, 1992, as supplemented by i

-letter dated March 17,'1993, complies.with.the standards and I

requirements of the Atomic Energy Act of.1954, as amended-(the Act),

and the Commission's' rules and regulations' set forth in 10 CFR Chapter I; i

B.

The facility will operate in confonnity with the application, as amended, the provisions of the Act, and the rules :and regulations of the Comission; C.

There is reasonable assurance:

(1) that the activities authorized by this amendment can be conducted without endangering the health.

and safety of the public,. and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this license amendment will not be inimical to the i

common defense and security or to the health and safety of the public; and E.

The issuance of this amendment is in accordance with 10 CFR Part~51 of the Coinnission's regulations and all applicable requirements have been satisfied.

i

  • The current owners of the Comanche Peak Steam Electric Station are: Texas Utilities Electric Company and Texas knicipal Power Agency. Transfer of-i ownership from Texas Municipal Power Agency to Texas Utilities Electric Company was previously authorized by Amendment No. 8'to Construction Permit CPPR-127 on August 25, 1988 to take place in-10 installments as-set' forth in -

the Agreement attached to the application for Amendment dated March 4, 1988.

At the completion thereof, Texas Municipal Power Agency will no--longer retain any ownership interest.

.~.

.. -, ~.

~

.,,,.,v.-

2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment and Paragraph 2.C.(2) of Facility Operating License No. NPF-89 is hereby amended to read as follows:

l (2) Technical Specifications and Environmental Protection Plan l

The Technical Specifications contained in Appendix A, as revised l

through Amendment No.

1, and the Environmental Protection Plan l

contained in Appendix B, are hereby incorporated into this license.

TU Electric shall operate the facility in accordance with the l

Technical Specifications and the Environmental Protection Plan.

3.

This license amendment is effective as of its date of issuance to be 1

implemented within 30 days of issuance.

FOR THE NUCLEAR REGULATORY COMMISSION g%b Suzanne Y. Black, Director Project Directorate IV-2 Division of Reactor Projects III/IV/V Office of Nuclear Reactor Regulation j

Attachment:

Changes to the Technical Specifications Date of Issuance:

May 21, 1993 l

l 1

4

i ATTACHMENT TO LICENSE AMENDMENT NOS.15 AND 1

)

FACILITY OPERATING LICENSE NOS. NPF-87 AND NPF-89 DOCKET NOS. 50-445 AND 50-446 Replace the following pages of the Appendix A Technical Specifications with the attached pages. The revised pages are identified by Amendment number and contain vertical lines indicating the areas of change. The corresponding overleaf pages are also provided to maintain document completeness.

}

REMOVE INSERT 3/4 3-51 3/4 3-51 3/4 3-52 l

l l

I i

Y

INSTRUMENTATION 3/4.3.4 TURBINE OVERSPEED PROTECTION l

tIMITING CONDITION FOR OPERATION i

3.3.4 At least one Turbine Overspeed Protection System shall be OPERABLE.-

APPICABILITY: MODES 1, 2*, and 3*.

ACTION:

a.

With one stop valve or one control valve per high pressure _ turbine l

steam line inoperable and/or with one stop valve or'one control valve per low pressure turbine steam line inoperable, restore the inoperable valve (s) to OPERABLE _ status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, or close ~ at least one valve in the affected: steam _line(s) or isolate the turbine from the steam supply'within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.

b.

With the above required Turbine Overspeed Protection System'otherwise-inoperable, within 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> isolate the turbine from the steam supply.

i SURVEILLANCE REOUIREMENTS l

4.3.4.1 The provisions of Specification '4.0.4 are not applicable. -

4.3.4.2 The above required overspeed protection system shall be demonstrated l

OPERABLE:

l a.

At least once per 6 weeks by cycling each of the following valves through at least one complete cycle from the running position using i

the manual test or Automatic Turbine Tester (ATT):

1)

Four high pressure turbine stop valves, 1

2)

Four high pressure turbine control valves, 3)

Four low pressure turbine stop valves, and 4)

Four low pressure turbine control valves.

b.

At least once per 14 days by testing of the two mechanical overspeed j

devices using the Automatic Turbine Tester or manual test.

l c.

At least once per 6 weeks by direct observation of the movement of i

each of the above valves through one complete cycle from the running l

position.

l

  • Not applicable in MODES 2 and 3 with all main steam line isolation valves 'and i

associated bypass valves in the closed position.

i-COMANCHE PEAK

" NITS 1 AND 2 3/4 3-51

' Unit 1 - Amendment No.15 Unit 2 - Amendment No. I

.~.

INSTRUMENTATION 3/4.3.4 TURBINE OVERSPEED PROTECTION SURVEILLANCE REOUIREMENTS (Continued) d.

At least once per 40 months by disassembling at least one high pressure turbine stop valve and one high pressure control valve and performing a visual and surface inspection of valve seats, disks and stems and verifying no unacceptable flaws.

If unacceptable flaws are found, all other valves of that type shall be inspected.

e.

At least once per 40 months by visually inspecting the disks and accessible portions of the shafts of at least one low pressure turbine stop valve and one low pressure turbine control valve and verifying no unacceptable flaws are found.

If unacceptable flaws are found, all other valves of that type shall be inspected.

l l

i l

l COMANCHE PEAK - UNITS 1 AND 2 3/4 3-52 Unit 1 - Amendment No.15 l

Unit 2 - Amendment No. 1 j