I..
. , . ,
22 JUN E90
Docket / License Nos:
50-317/DPR-53-
50-318/0PR-69
Baltimore Gas and Electric Company
ATTN: Mr. George C. Creel
Vice President - Nuclear Energy
Calvert Cliffs Nuclear Power Plant
MD Routes 2 and 4
Post Office Box 1535
Lusby, Maryland 20657
Gentlemen:
Subject:
NRC Region I Resident Inspection Report Nos. 50-317/90-09 and
50-318/90-09 (April 29, 1990 to June 2, 1990)
This report transmits the findings of the routine resident inspection conducted
at the Calvert Clif fs Nuclear Power Plant. At the. conclusion of the inspec-
tion, these findings were discussed with Mr. Denton of your staf f.
Areas examined during this inspection are described in the NRC Region 1 Inspec-
tion Report which is enclosed with this letter.
Within . these ' areas, the
inspection consisted of selective examinations of procedures and representative
records, interviews with personnel, and observations by the inspectors.
Within the scope of this inspection, no violations were observed.
Your cooperation with us is appreciated.
Sincerely,
'A.Q
"
.
James C. Linville, Chief
'
Reactor Projects Branch No. 1
Division of Reactor: Projects
Enclosure:
NRC Region I Resident Inspection Report Nos.- 50-317/90-09 and
50-318/90-09
0FFICIAL RECORD COPY IR CC 90-09 - 0001.0.0
.'
06/14/90
y
/
90070200099006h{^g7
o
ADOCK ococ
/
'
j
'
' , , . ,
'-
Baltimore Gas and Electric Company
2
cc w/ encl:
R. McLean, Administrator, Nuclear Evaluation
G. Adams,Liceasing(CCNPP)
J. Walter, Engineering Division, Public Service Commission of Maryland
i
K. Burger, Esquire, Maryland People's Counsel
-
P. Birnie, Maryland Safe Energy Coalition
Public Document Room (POR)
Local Public Document Room (LPOR)
Nuclear Safety Information Center (NSIC)
NRC Resident inspector
State of Maryland (2)
bec w/ enc 1:
Region 1 Docket Room (with concurrences)
Management Assistant, ORMA (w/o enc 1)
T. Martin, RA
R. Burnett, ORA
M. Knapp, DRSS
W. Hodges, DRS
W. Kane, ORP
J. Wiggins, ORP
J. Linville, DRP
0. Vito, DRP
R. Summers, DRP
C.'Cowgill, ORP
K. Lathrop, DRP
L. Nicholson, SRI - Calvert Cliffs
J. Durr, DRS
R. Gallo, DRS
R. Bellamy, DRSS
K. Abraham, PA0
M, Taylor, SLO
J. Caldwell, E00
0. Mcdonald, NRR
M, Callahan, OCA
,
,
,0
Rl:0 P
i
RI:0RP[lb
RI:0RP
'
LHicholson/mjd
CCowgill
JLinvi
6/I'[/90
6/f/90
6/)f/90
0FFICIAL RECORD COPY IR CC 90-09 - 0002.0.0
06/14/90