Text

w...

r,

'g h

3[; QW MATTINGLY TESTING SERVICES, INC.

L,

= P.O. Box 3126 Great Falls, Montana 59403 (406) 452-8752

=,. _,

Q

- m-June 12, 1990, Mr. Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety

-Office of Nuclear Material Safety and Safeguards United States Nuclear Regulatory Commission Washington, DC 20555

Subject:

Request for renewal of Quality Assuranco Program.

Registration for Certificates Dear Mr. MacDonald; Mattingly Testing Services, Inc. (formerly known as Mattingly

& O'Reilly Services and Testing, Inc.) request renewal of our Quality Assurance Program for Radioactive Material Package No. 0542, which expires on June 30, 1990. A copy of-this O.

A.

Program is enclosed along with check no. 3850 in the amount

.of 150.00 (required application fee).

We aretalso' requesting registration for Mattingly Testing Services, Inc., NRC License No'.

25-21477-01, as a Certificate Holder and User for the following enclosed certificates:

1) Certificate No. USA /0121/S
2) Certificate No. USA /0166/S
3) Certificate No. USA /6717/B(U)T 4)' Certificate No. USA /9160/B(U)T
5) Certificate No. USA /9006/B(U)T 6)' Certificate No. USA /9135/B(U)T Please contact me at (406)264-5471 or at the above address

.if.you have any-questions or require additional information.

-Sincerely, f

'I ;

'. Mark M.

Mattingly Radiation Safety Officer g

?

.sdm l-Enclosures 1

d i

O kb i

1

'#"~N"'v ~

    • "f4 8

NUCLEAR REGULATORY COMMISSION i

WASHINGTON, D. C 20555 '

MAY 15 1990 '

SGTDsGMB 71-0542 Mattingly & O' Reil;,y Services

& Teuting., Inc.

ATTN:

Mr Mark M Mattinn.ty P.O.

Box 3126 Great Falls., MT 59403 Gentlemen:

Your. Quali ty Assurance Program Approval for Radioactive Material Packages No OS42 expiren on June 30, l990 I f you are an NRC licensee and conduct activiLies under the General Licenses of Subpart C of 10 CFR Part '71 or if you-3 are an Agreement State licensee subject to the requirements of 10 CFR Part 71, you are required by 10 CFR Part 130.20 to hold a quality ansurance (On) program approvea by the

. Commission as natisfyin a the provisionn of Subpart H of 10-CFR Part'71.

You shou:ld request renewal of your quality asuurance program at least 30 dayn prior to the expiration date.

.This will provide "for continuation of your UA program to satisfy part of-the provinionn of Subpart C of 10 CFR Part 71 un til a fina] determination has been tal:en on your application

- s

~Unless an. exemption is provided by 10 CFR 170.11, an appli-cation fee of $150.00, as required by 10 CFR Part l'70 31, should be included with your request for renewal.. This

-notico of-expiration shou]c not be construed that such notice will be provided-in the future.- 11 you do not

.~ desire to renew your OA program, please let me i<n ow.

Gincerely, Charles E.

MacDonald,. Chief Transportation Branch Division of Safeguards and Transportation l

/

h :,.m is n OG

1) U p / f U # U f;

1 r

E. '

Paga 1 of ~2 TTING.TESilNG SERVICES. INC.-

NRC LICENSE #25-21479-01 February 2, 1989 s

QUALITY ASSURANCE PROGRAM i

~1._0RGANIZATION The ultimate-responsibility for the QA Program in accordance with Part 71 requirements rest with Mattingly Testing Services, p

Inc.'

Design and fabrication shall not be accomplished under this QA program.-The Assistant' Radiation Safety Officer is designated as'the responsible individual for Part 71 quality assurance requirements.

l The Radiation Safety Officer is responsible for the overall administration-of the-QA Program and for training and certification.

The Assistant Radiation Safety Officer is responsible for document control and audits.

The Radiographers are responsible for handling, storing, shipping, inspection, test and operating status and record keeping.

2. QUALITY" ASSURANCE PROGRAM

-The management of Mattingly Testing Services, Inc. establishes

.and! implements this QA Program.

Training prior to performing HQA activities.is required'in compliance with written procedures.

RevisionsEto=the QA. Program shall be made in accordance with written procedures and with management approval. The QA Program will ensure that all defined QA procedures, engineering procedures and specific' provisions for package design approval are satisfied.

The QA Program shall emphasize control of characteristics of the package, which are critical to~ safety.

The Assistant Radiation. Safety Officer shall assure that all radioactive materials-shipping packages are designed and-manufactured under a QA' Program approved by the Nuclear Regulatory Commission for all packages designed and fabricated after January-1, 1979.

This' requirement may be satisfied by receiving a certification to this effect from the manufacturer and/or supplier.

3. DOCUMENT CONTROL All. documents related to a specific shipping package shall be

_ controlled through the implementation of written procedures.

All document changes shall be accomplished in compliance with written procedures approved by management.

L

.The Radiation-Safety Officer shall assure that all QA functions are conducted in compliance with the latest applicable changes to these documents.

G'&f)')Dl/h')//

fu;f ve ' t "n /

y.

(j e.

'!Wh

!^s

~

c; TTING TESTING SERVICES. INC.

%g* 7

^f

4. HANDLING, STORAGE AND SHIPPING 1 Written safety' procedures concerning the handling, storage and.

shipping of packages for certain special form radioactive material r

will be,followed. Shipments will not be made'unless all tests,

. certification, acceptances and final inspections have been completed.

Work instructions will be provided for handling, storage and shipping operations.

Radiography' personnel.shall perform the critical handling, storage and shipping. operations.

k, 5.

I NS P ECT 7.ON, TEST AND OPERATING STATUS i

h

' Inspection,~ test and operating status of packages for certain l

radioactive material will be indicated and controlled by~ written i

procedures. The status shallibe indicated by tag, label, marking f

and/or log entry. The status of nonconforming parts and/or packages

-j shall be maintained in compliance with written procedures.

Radiographers shall perform the Commission's required inspections and tests'in accordance with written procedures. The Radiation Safety officer shall assure that these' activities are performed.

l 6.

QUALITY ASSURANCE RECORDS Records.of package approvals (including references and drawings)

. procurement, inspections, tests, operating logs, audit results,-

personnel training and qualifications and records of shipments shall be maintained. Descriptions of equipment and written procedures shall also be maintained, a) The' records will be maintained in accordance with a written procedure.

b) The records will beLidentifiable and retrievable, c) The radiation Safety Officer shall maintain a list of the records and their storage locations.

7. AUDITS An established schedule for audits of the OA program shall be implemented in conducting audits using written procedures and/or.

check-lists. Results of audits shall be maintained. Audit reports shall be evaluated and deficient areas shall be corrected. The audits shall'be dependent on the safety significance of the activity being audited,' but each activity shall be audited at least once each year. Audit reports shall be maintained as a part of the quality assurance records. The Auditor shall not have direct responsibility for the activity being audited.

Mark M. Mattingly Radiation Safety Officer Mattingly Testing Services, Inc.

l D

- -.V k'

[

Y.

r k k+

(/ ;.

d5 Deponment of ironsponoton -

400 Se.enm sweet, s W w.3%.a. o e rosso Reseorth ond i

l$1n o% 8 -.lAEA CERTIFICATE OF COMPETENT AUTHORITY f

^ Special Form Radioactive Material Encapsulation i

_ Certificate Number USA /0121/S (Revision 4)

This certifies that the encapsulated sowces, as described, when loaded with the cuthorized radioactive contents, have been demonstrated to meet the regulatory rcquirements for special form radioactive material as prescribed inlAEA lj and USA L 2f regulations for the transpc-t of radioactive materials.

Ic Sowce Description - The sources described by this certificate are identifled as Gulf Nuclear Inc., Models RA-17;' RB-1, -2, -3, -4, -5, -6; RC-16; RG-13; RCSA-13; e

RS-12; RR-7, -9, -10, -11, -18; RS-18; RT-14, -15; RPL-4C, -lG, -2NA, -5, -3T; RAR- -

17; and RAG-17, which are welded encapsulations constructed of stainless steel and measure 0.240"in diameter and 0.400"in length.

11.

. Radioactive ' Contents - The authorized radioactive contents of this sot I

consist of not more than 200 Curles of Iridium-192 as metal pellets.

111... This certificate, unless renewed, expires May 31,1988.

This certillcate is issued in accordance with paragraph 803 of the IAEA Regulations 1),- In' response to the ~ petition by Gulf Nuclear, e

Inc., Wester, Texas - and in consideration of the associatedird armation therein.

Certilled by:

/00 duoad2U984 Richard R. Rawi Chief, Radioactive Materials Branch (Datp t

Office of Hazardous Materials Regulation

Materials Transportation Bureau 1973 Revised Edition", published by the International Atom Vitnna, Austria.'

l2/ Title 49,' Code of Federal Regulations, Part 170-178, US A.

- Rivision 1 issued to extend expiration date.

Revision'2 - extended expiration date; reflected conformance with 1973 IAEA regulations.

Revision 3 '- added model RAR-17.

/

I

. Revision 4 - added model RR-18.

L J

l

a US Depor1 ment

u. s,..nu, si,,,i 3 w ofIronsporlotion we.agion D C X4W J

nosearchand

. IAEA CERTIFICATE OF COMPETENT AUTHORITY Spec 6al Programs NM68" Special Form Radioactive Material Encapsulation Certificate Number USA /0166/S (Revision 4) 1 This certifies that the encapsulated sources, as described, when loaded with the authorized radioactive contents, have been demonstrated to meet the regulatory requirements for special form radioactive material as prescribed b lAEA l_/ and USA l

2/ regulations for the transport of radioactive materials.

j l.

Source Description - The sources described by this certificate are identified as the following Gamma industries models which are constructed according to the listed drawing numbers:

Model No.

Drawing No.

VD and VD(HP) 602-7001-004 NB, NBG and NB(HP) 602-7001-005 Single Encapsulation Universal Source 602-7001-006 Double Encapsulation Universal Source 602-7001-007

- Single Encapsulation Side Weld 602-7001-008 All models are welded encapsulations constructed of 300 series stainless steel or ARMCO Type 17-4PH stainless steel.

11.

Radioactive Contents - The authorized radioactive contents of these sources consist of not more than:

Model No.

Contents -

VD and VD(HP) 300 curies of Barium-131 Manganese-54 Cadmium-109 Phosphorus-32 Calcium-45 Rubidium-86 Calcium-47 Selenium-75 Cesium-137 Strontium-85 Chlorine-36 Thallium-204 Chromium-51 Thulium-170 Iridium-192 Tin-ll3 Cobalt-60 Ytterblum-169 Iron-59 Zinc-65

2 Certificate Number USA /0166/S, Revision 4 11.

Radioactive Contents (continued)

Model No. (cont'd)

Contents (cont'd)

NB, NBG and NB(HP) 23 Cwles Americium-241 30 millicuries Ra-226 500 millicuries Americum-241 and Ceslum-137 mixture Single Encapsulation Universal foruce 500 curies Irldlum-192 20 curies Cobalt-40 Double Encapsulation Universal Source 3000 curles Iridium-192 2000 curies Cobalt-60 Single Encapsulation $1de Weld 300 cutlas Iridium-192 y

20 curies Cobalt-60 111.

This certi!!cate, unless renewed, expires July 30,1987.

This certlilcate la issued in accordance with pNagraph 803 et the IAEA Regulations and in response to the May 1% 1984 petition by Gamma Indurtries, Baton Rouge, Loulslana, and in consideration of the associated 1.a. formation therein.

Certified by:

=

60kb0wh 6 4 /3.1984 Richard R. Rawl

(@te) U Chief, Radioactive Materials Branch Office of Hazardous Materials Regulation Materials Transportation Bureau 1/ "5af ety 5eries No. 6, Regulations for the Safe Transport of Radioactive Materials T973 Revised Edition", published by the International Atomic Energy Agency (IAEA),,

Vienna, Austria, jf Title 49, Code of Federal Regulations, Part 170-178, US A.

Revision 4 issued to correct materials of construction speelfication.

g g

w p neion. D C. FM m Research and 5pecnol Pro 9 tomb AdmMirolion IAEA CD7IFICATE CF Crr4PETDTP 1&rlDRITt Type B Radioactive Paterials Package Design, Cbrtificate thrnber USA /6717/B(U)T (Bevision 1) o

+,

nis establishes that tie packaging design described terein, when loadai with the authorizcd radioactive contents, hss b.cn certified b> the flational Competent Authority of tle Unittd States, as necting 'the regula-tory requirertents for Type B packaging for radioactive noterials as pre-scribed in IAEA lf Ngalations and SS 49 cra 173.393a ard 173.394 (b)(.1) of the USA 2/ Ngulations for the transport of radicoctive noterials.

I.

Package Identification - ttdel 16. 6717-B.

II. Packaging Description - Padaging aut)cri2cd by this certificate consists of an outer lo gallon steel drun with an inner container which is a netal-walled container nceting the requirutents of Inr Spccification 7A, surrourded by polyurethane filler and a 1-1/2" asbestos free liner.

Gross might is approxinately 75 pousds.

III. Autlerized Radicettive Contents - Tre acthorize3 contents ' consist of radioalEtive naterials, n.o.s,. as rot nore than 200 curies of iridium-192 as sealed sources which nust nect the requirments for special form as set forth in 49 CFR 173.389(g).

Centents nust be of a design whicg has teen testad and deacastrated to be leaktight to a snnsitivity of 10- atm-a::/sec or less.

IV. General Conditions -

Dach user of this certificate nust have in his possession a copy of a.

this certificate.

b.

Dach user of tlas certificate, other than Gamia Irdustries, Baton j

Touge, louisie.i, shall registe-hi* Mentity in writing to the Office of 11azardous Materials Regulation, U.S. Departncnt of Transportation, Washington, D.C.

20590.

This certificate dces rot relieve any consigror or carrier f2nn c.

cmpliance with any requiraient of the Goverment of any country through or into which tic package is to be transported.

Marking ard labeling - %e package nust bear the narking USA /6717/B(U)

{

V.

as wall as the other narking ard labbis prescritrd by the USA Ngulations.

      • W
  • POpt RAD 60 ACTIVE ALATE!!ALS PA00LA088 L,,eend manie o w ete

-.paon a eswie w o.u.oie e o.m te

. voi e.e o.

j 9006 l

9 L5A/9006/8(U) 1 2

.~.

em. w.moeu mio n.ev.ineenn o e si nep.asi ni. con ti. e.csee.no e e no w eenom.ee crees in nom s me

..no.

swai.= wm, wheem wii.nhin tn. 50.c.ee r

tronwonei.n. nw.e.ei.. nasi.e h

b The eartelisme esos hot rolese the coregrer trom compience enh any soevimment et the espuietions of the U s Desertment of transporteten er other aspimene sepuistory spences mcisoing u povernmeni o any sew try throsch or mis which t% pochepe w li to transportec s

n

$1 e areCA 16 Sk THE DAbit CW a SAFgTv Ate 44v6:$ ht 1

THE og MS o.s De e%

Oss

(

Amersham Corporation Tech / Ops Inc. application 40 North Avenue dated March 31, 1986.

i 1

Burlington, MA 01803 l

l 4.

J1 9006 e nac=, w e co.oto.,s ThO tertificate e COnditense pon luffalieng the regwivement6 of to CFm Port 71, es applicat>ie. en0 the ton 6itaans specited telom u

(a)

Packaging i

i (1) Model No.:

Al 500 SV (2) Desc ription A radiographic source chahger consisting of a welded 10-gauge stainless steel box, anproximately 5 wide x 6* high 411" long.

The source changer has a positive closure hinged flat plate cover and a depleted uranium shield.

Two titanium tubes are positioned in the center of the depleted uranium and house the source capsules and the source cable assemblies.

The two openings are closed by locking assemblies and thread (d caps.

The gross weight is approximately 65 pounds.

4 (3) Drawi ngs i

The packaging is constructed in accordance with Tech /Op',, Inc.

Drawing Hos. A15005U90, Sheets 1 through 7 of 7. Rev. B; A1500SU91, Sheets 1 and 2 of 2; A15005092; and optional Drawing No. A15005U93, j

Rev. A.

I (b) Contents (1) Type and fonn of material Iridium 192 as a sealed source Sich meets the requirements of special form radioactive material.

(2) Maximum quantity of material per package 120 curies

'l m____----------__--------------_---------_mw-~

r m.

..m________,

- * ' ! ' e' * "

o r. e.unt n i.t e.v$aten cowmpitw r

^ Page 2 - Certificate No. 9006 - Revision No. 9 - Docket No. 71-9006 e

6.

The source shall be positioned within the titanium tubing by a source cable l

assembly which meets the parameters shown in Tech / Ops, Inc. Drawing Nos. 42402-l l

i 1

Rev. F, and 42402-4, Rev. B.

l t

i 7.

The name plate shall be f abricated of materials capable of resisting the fire l

I test of 10 CFR Part 71 and maintaining its legibility.

i 8.

The package authorized by this certificate is hereby approved for use under the I

generpl license provisions of 10 CFR $71.12.

]

'I 9.

Expiration date:

May 31,19(B R E G 9,.

l D(>

REFERENCES i

'O i

s e-

/'

Tech / Ops, Inc. applicat'lon dated March 31, 1986.

?

/,

I l1 V:

N%.

ss l

Ni;.3 \\

s'.

FOR AfE' ALS. NUCLEAR REGULATORY COMMISSION ll N

( )

l

/ y; e

.~..\\

ll q/

\\;

x r

n, ti

~

. *.ch - -

  • j m_ _

j

[

5-v..C r es n00na..Mbier M i

3 It ansportation. Certification Branch I

^

Division of Fuel Cycle and I

Material Safety, INSS

[,

em:

m_c 3 e 4

1

.I l l

/

1 :

I I

I I

1 1

1 I

I I

l

'l l

l l l I

y.

I I

I i

I i

I, I

i 1

I i

I, c

gg d

I g

o s m.,o. _,

Ofl'o'up M o @

v'* W'pr#'

C P Research ond Speciol Pt09 roms Administration I AEA CERTIFICATE OF COMPETENT AUTHORITY Type B Radioactive Materials Package Design Certificate Number USA /9135/B(U)T Revision 0 4

This establishes that the packaCing design described herein, when loaded with the authorized radioactive contents, has been certified by the National Competent Authority of the United States as meeting the regulatory requirements for Type B packaging for radioactive materials as prescribed in IAEA Regulatiop and in accordance with 49 CFR Sections 173.393b and 173.394(b)(3) of the USA Regula-tions for the transport of radioective materials.

I.

Package Identification - Model Nos Century S, Century SA, Century Universal S, and Centry Universal SA.

1 11.

Psickr.ging Descript!on - Packaging authorized by this certificate cons!sts of a zircelloy or titanium "S tube which is surrounded by depicted uranium shleiding which is encased in an outer steel housing. The void t.etween the shiciding and housing is filled with polyurethane foam.

External dimensions are 7.0 inches long by 5.5 inches in diameter with a gross weight of 45 pounds.

!!J.

Authorized Radioactive Contents - The authorized contents consist of special form encapsulations meeting the requirements of 49 CFR )?3.389(g) and convaining not more than 120 curies of Iridium-192.

Contents must be of gdesign wg/sce or less,ich has been tested and demonstreted to a r,ensitivity of 10' atm-cm t

I V.

General Conditions -

Each user of this certificate,must have in his possession a copy of a.

this certificate.

b.

Each user of this certificate, other than Gamma Industries, Baton Rouge, LA shall register his identity in writing to the Office of Hazardous Materials Regulation, Materials Transportation Bureau, U.S. Department of Transportation, Washington, D. C. 20590, c.

This certificate does not relieve any consignor or carrier from compliance with any requirement of the Government of any country through or into which the package is to be transported.

t

I l

Certificate Number USA /9135/B(U)T, Revision 0 Page 2 V.

Marking and thbeling - The package must bear the marking USA /9135/B(U) as well as the other marking and labels prescribed by the USA Regulations.

1987. ppiration Date - This certificate, unless renewed, expires on April 30, Yl.

.s This certificate is issued in accordance with the requirements of the IAEA and USA n

f Regulations and in response to the June 21,19B2 petition by Gamma Industries, Baton Rouge, LA and in consideration of the associated information provided in U.S. NRC Certificate of Compliance No. 9135 (Appendix A) and related corre-spondence.

Certified by:

A!

b hichard R. Rawl D9tc Chief, Radionet!ve Materials Branch Offlee of Hazardous Materiels Regulation Materials Transportation Bureau I" Safety Series No. 6, Regulations for the Safe Transport of Radioactive Materials, i

1973 Revised Edition" published by the International Atomic Energy Agency (IAEA),

Ylenna, Austria.

1 Title 49, Code of Federal Regulations, Parts 100-199, USA.

i 0

e 6

4 c

d

__ - ---- - _ _ _ _ _ _ _ _ _ _ - - - - - -awawarm. m~ w _.... _ _' i U.S. touCLEA3 atauLAT0mf CotettistION I asmsipoempe t

CERTIFICATE CF CSMPLIANCE FOR RADICACTIVE C' ATE tALS PACKA!es

',,' an ums.

F #

.e e m.ca.ne o ro..u et.

...c.,

..ii

...,j

. v o m.

9160 1

USA /9169/Bful 1

l

. Th..one.sai. m 6 u.o to enety Mt th. p.ck. ping.nc cent.nt6 e cri.ee in tiem 6 te60s. eneet, In. oppiut,te et,.i.rio.,es.e lona en Tai.10.Cese i

c 3 4Amett f

pf Posee.l h.,wi.t on. P.,t t1.*P.ck.p.ng.,se t,. spon.ison of On.cectiv. 64.se,el *

.t, unieui.me.nn wn..,,

e,.mcome..c...i 9,

niein.

i.i. e mvso.p.n niut,.n. con.in.

I J

.,e uwi.

.i.i.,,.p

..nci.e u p,. nie.~,toonier m en...ni.

.en n p.c6.

..u i,.%,on 1

l l

t,.isggogs e uto ce t>< mass cv a suen awesis,.t,a4c 5 gtgag$goa icg.cw I

l l

l Arersham Corporation Gulf Nuclear, Inc. application dated 40 North Avenue Jarvary 21, 1954, as supplemented.

l l

t lj I

Burlington, MA 01803 t

I 71-9100

. anan.u l

l I

vi..en.

. ne n.i u a,omine a.n. e w er a e.n 7i.

.posat..no e oit on ea..e m.i.

. ca orto 1

I l

6 I

I (a) Packaging 7

(1) P.cde$)os,f 20-VS and 40-VS

,a

-i *

(2) Des}Hption fc' I

R6diographic divices. and shipping conta,inE fer sealed..scurces.

?be I

packagesareapproxipately.12".high4/6t'widex8"ic.pp. The outer I

case is constructed ot.35 gauge 303 $$tilevs steal. <The package is held in plice.by. potting (p$r'ywdY., lhe 34 pound Ur'anium sh provided with a O'.74%di_antp l

1 y.p d f brackets within t6e case.

The i

I sealedscurce%sheldpit rg ) prgloy or. titanium 5-tube by a lockb1cck I

asstmbly and a3efety plug aggtJy;.4t theropposite..~end cf the S-tute.

I The P.odel Ncs.'f20-VS eet 404'E' ate-4dstitel except<for shielding capabiliJy cf the' uranium shield'.s Theg,'ackage wefgtis 4? peu I

.w

-4 e

l l

(3)

Drawing [A.

' '. ' ' 2

-('

I The packag ccr.structed in accordance witt Gulf Nuclear, Inc.

R 1; A-31-1, Sheets 1 and 2, Drawing Nos. A-31,peet.s 3 and 4 I

.0 31-16, Rev. 1; A-31-18. Rev.

j Rev. 0; A-3-1, Res.. I t'A' dig $ bee 1, 2 and 3. Rev. 1; A-31-31, 1; A-31-20, Rev.1; A-31 21, Sheets 1, 2, and 3. Rev.1; A-31-32 Rev. 0; A-31-34, Sheet 3, Rev.1 I

I and Sheet 4. Rev. 0; 1000-5014, Rev. 0; and 1000 50-13. Rev. O, I

I I

l 1

l l

l l

l l

l l

-N l

G9 As, a n vlh I

12_v u t l&-

L '- - - -- - -- - - - - - - - - - - - - - - - - - - - - - - - - - - -'

l m.

~... __. ~~.~.

.~...,..c.

m.gg % m.m n conomons teontn ers v

j Page 2 - Certificatt ho. 9160 - Revisier No.1 - Docket No. 71 9160 i

I.

j 1

(b)

Contents (1) Type and form of material l

Iridiutt.192 as sealed source which n:ust be shown to freet the regt.irererts i

i of special form radioactive mattriel.

I 1

(2) Maximum quantity of material per package One Source containing:

(i) Model No. 20-VS package - 120 Ci; or (ii).Model No. 40-VS package - 220 Ci.

6.

The package model designation trust be detern.ined by the initial Acceptance j

criteria given in Section 5.3 (p 5-3) of the application, 7.

The packages authorized by this certificate are hereby approved for use 1

under the general license provisicns of 10 CFR 671.12.

l l

.P.

Expiration date: April 30, 1989.

o 1

i REFERENCE

.[

1 t

h~

Gulf Nuclear, Inc. application dated January 21, 1984.

I 1

Supplernents dated:

March 6 and 20, 1984 1

l' I

I FOR THE U.S. NUCLEAR REGULATORY COMMISSION t

I I

h v

1[

Charles E. MacDonald, Chief i

I:

Transportation Franch r

Division of Safeguards and

.l l

Transportation. FMSS I

FEB 191988 q

Date:

I 1l-li 4

li 1

1 1

1 1

I

!i i

)

.........y m

.,,..,[**'.\\

UNITE D STATES

'e, NUCLE AR REGULATORY COMMISSION WA6HINGTON D. C. 20666 l

Transportation Branch Approval Record l

Models 20-V5 and 40-V5 Packages Docket No. 71_9160 Revision No. 1 w

l By application dated December 15, 1987, Amersham Corporation requested Certificate of Compliance No. 9160 be issued to~them. Amersham Corporatior.

purchased Gulf Nuclear, Inc. and will be responsible for the maintenance of the certificate, safety analysis report for the cask design and quality assurance L

records in accordance with 10 CFR 671.91(c).

Amersham Corporation has been l

previously issued Quality Assurance Program Approval for Radioactive Material Packages No. 0040 under Subpart H of 10 CFR Part 71,

.c.ch Charles C. MacDonald, Chicf I

Transportation Branch Division of Safeguards and Transportation, NKSS Date:

FEB 19 2 9

l j

-...