ML20043B264
| ML20043B264 | |
| Person / Time | |
|---|---|
| Site: | LaSalle |
| Issue date: | 06/14/1988 |
| From: | Marchleuba J OAK RIDGE NATIONAL LABORATORY |
| To: | Huang T Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML20042D069 | List: |
| References | |
| FOIA-90-13 NUDOCS 9005250166 | |
| Download: ML20043B264 (1) | |
Text
{{#Wiki_filter:f,,. '. S. t 4 t OAK MlDOE NATIONAL LABORATORY Post once som a oaa men.vtwassee um ) opteiAtto gy unarm uantita gasov sysitus, we. June 14, 1988 RO Mr. Tai Huang Reactor Systems Brar.ch Division of Engineering and Systems Technology U.S. Nuclear Regulatory Commission VIH 8E23 Washington, DC 20555 Reouest for RES Assistance in Evaluation of LaSalle Instability Event
Dear Tai:
I have reviewed the memorandum from H. W. Hodges to L. Shotkin dated June 2,1988, on the request for RES assistance in evaluation of the laSalle event. Enclosed are some general comments about the memorandum and about LAPUR's capabilities in this area. Please call me (FTS 624 5571) if you need further assistance. Sincerely, x p A cL-k c Jos6 March 14uba JML:kj s cc/ enc: E. D. Blakeman N. E. Clapp D. N. Fry L, D. Phillips (NRC) y L .w 9oos25o166 90o32e PDR FOIA PDR l HIATT90-13 =}}