ML20042E495

From kanterella
Jump to navigation Jump to search
Notification of Rev 1 to Significant Licensee Meeting 90-37 W/Util on 900430 to Discuss Findings/Conclusions of Augmented Insp 50-219/89-81 Re Low Condenser Vacuum Transient
ML20042E495
Person / Time
Site: Oyster Creek
Issue date: 04/10/1990
From: Ruland W
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 9004230274
Download: ML20042E495 (2)


See also: IR 05000219/1989081

Text

,

,

c.,

~9 o

,

' ,.

,

APR 101903

U.S. NUCLEAR REGULATORY COMMISSION

No. 90-37

!

REGION I

Revision 1

i

NOTICE OF SIGNIFICANT LICENSEE MEETING

'

Licensee:

General Public Utilities Nuclear Corporation

1

Facility:

Oyster Creek

Docket No:

50-219

Time and Date:

1:00 P.M., April 30, 1990

i

Location:

ORS Conference Room, Region I

King of Prussia, PA

.

,

Purpose:

Discuss Findings / Conclusions of Augmented Inspection,

'

50-219/89-81, Low Condenser Vacuum Transient

NRC Attendees:

T. Martin, Region I Administrator

W. Hodges, Director, Division of Reactor Safety (DRS)

R, Gallo, Chief, Operation Branch, DRS

+

R. Conte, Chief, Boiling Water Reactor Section, DRS

,

l

T. Eas11ck, Operations Engineer, DRS

'

J. Wiggins, Deputy Director, Division of Reactor Projects

(DRP)

E. Wenzinger, Chief, Projects Branch No. 4, DRP

^

E. Collins, Senior Resident Inspector

Licensee Attendees: E. Fitzpatrick, VP/ Director, Oyster Creek

R. Barrett, Plant Operations Director

"

J. Sullivan, Emergency Preparedness Manager

M. Heller, Oyster Creek Licensing Engineer

E. Roessler, Manager, Nuclear Safety

A. Rone, Plant Engineering Director

W. Popow, Site Service

Note: Attendance by NRC personnel at this meeting should be made known by

4:00 p.m. on April 28, 1990 via telephone call to R. Conte, Region I, at

FTS 8-346-5210 or commercial 215-337-5210.

This is an open meeting.

Preparedby://

N

' William H.'Ruland, Acting Thief,

i

DRP Section 4B

i

!

0FFICIAL RECORD COPY.

MEETING NOTICE NO 90-37 - 0001.0.0

03/15/90

9004230274 900410

't

gon

noccxosoog9

/

go-

r

]

.,

w.

,

.

,

.,.4

l

Di stributi_on:

J. M. Taylor, Executive Director for Operations

Deputy Executive Director for Nuclear Reactor Regulation, Regional

Operations and Research (DEDR)

H. Thompson, Deputy Executive Director for Nuclear Material Safety, Safeguards

and Operations Support (DEDS)

8. K. Grimes, Director, Division-of Reactor Inspection and Safeguards, NRR.

J. Lieberman, Director, Office of Enforcement

T. E. Murley, Director, Office of Nuclear Reactor Regulation

F. J. Miraglia, Associate Director for; Inspection and Technical Assessment, NRR

B. Boger, Assistant Director for Region I Reactors, NRR

J. Dyer, Regional- Coordinator, EDD

J. Stolz, Director, Project Directorate I-4, NRR

>-

A. Dromerick, Project Manager, PD I-4, NRR-

W. Bateman, NRR

Public Document Room (PDR)

Local Public Document Room (LPDR)

State of New Jersey

bec:

Regional Administrator

Deputy Regional Administrator

Division Directors

Branch Chiefs

Section Chiefs

Public Affairs Officer (2 copies)

M. Miller, RI

D. Holody, RI

K. Smith, RI

Region I Receptionist

DRMA Files

DRP Files

Bulletin Board

M. J. DiDonato, DRP

R

01

Ruland

Wenz1nger

03/15/90

0FFICIAL' RECORD COPY

MEETING NDTICE NO 90-37 - 0002.0.0

03/15/90