ML20042B095

From kanterella
Jump to navigation Jump to search
Forwards Vendor Insp Rept of Dravo Corp on 690107-09
ML20042B095
Person / Time
Site: Dresden, Indian Point, Turkey Point, Quad Cities, 05000000
Issue date: 02/25/1969
From: James O'Reilly, Oreilly T
US ATOMIC ENERGY COMMISSION (AEC)
To: Boyd R
US ATOMIC ENERGY COMMISSION (AEC)
Shared Package
ML20042B096 List:
References
NUDOCS 8203240559
Download: ML20042B095 (2)


Text

_

,o RD 2 51969 o

CO f3h 0

CO FJNolan JGReppler:kbp JP0' Reilly 2/24/69 2/24/69 2/24/69 R. S. Boyd, Assistant Director for Reactor Projects hit '

Division of Reactor Licensing (2)

C0FM0!MFALTH EDISON CCMPANY (DZ:CD23 2) DCCKET NO. 50-237 69-1 C0f0:0:P.CALTH EDISON CCMPANY (DICGE".3 3) DCC= T no. 50-249 69-1 C0:2'0 CiEALTH EDISON CC'IPM (QUAD CITES 1) DOCET NO. 50-254'69-1 cc: :0:mEALTH EDISO:1 CC:!PM (CUAD CITIES 2) DOC'CT UO. 50-265 69-1 CONSOLIDATED EDISON CCMPANY (IUDIAN POILT 2)

DOC.'tET NO. 50-247/69,

FLORIDA TOWER AND LIGHT COMPAI.T (TUREY POIZ7f 3) D0cr T to. 50-250/69-1 FLORIDA PO'JER AND LIGET CC'iPANY (suura.a ICIET 4) DOCCT NO. 50-251/69-1

.The enclosed report of a vendor inspection visit to the Drnvo Corporation on January 7-9, 1969, is forwarded for infor::stion. The primary purpose of this inspection was to review the quality assurance programs associated with the fabrication of pressure piping for certain reactor pro,1ects.

It vns scheduled at this time beenuse of deficiencies cetected in stain-less steel piping shipped by Dravo to the Indian Point 2 cite. This problem is discussed in CO Heport No. 247/68-5 The existence of fissures in certain stainless steel piping that was shipped from Dravo to the Indian Point 2 cite resulted frc::1 inadequate inspection requirements at the vendor plant. Dravo's inspection pro-gram has been noticeably strengthened since the discovery of this problem. The prompt detection of this proble:s at the C nsolidated Edison site reflects credit on their receipt inspection program.

Our audit of Dravo's current fabrication and quality control activities, relating to piping systems for Dresden 2 and 3, Quad Citics 1 and 2, Indian Point 2, and Turkey Point 3 and 4, choved that corrective measures have been taken and that these activities are nov vell documented and in i

compliance with codes, standards, specifications, and good practices.

On the other hand, the vendor inspection programs being carried out at Dravo by applicants, with the exception of Turkey Point 3 and 4, were noted to have notable venlutosses. Thece deficiencies are being pursued as part of our routine construction inspection program.

J ',

Odgnd signed 8 r, n r:s'y J. P.i' 0'Reilly, Chief Reactor Inspection and Enforcement Branch Division of Compliance

Enclosure:

CO Report Nos. as above b g~ d /

ccv/ enclosure:

L. Kornblith, Jzj., CO R.; W. S:nith, CO:V crmEn gp. Case, DRS

.-R. W. Kirkman, CO:I-H. D. Thornburg CO:III I

S. lLevine, DEL (d)

J. G. Davis,CO:%I v/o each

""D t J..h<ovhol t, ORL (3)

D.-I.. Walker, CO:IV~

ECG Central File-I nu,

i 8203240559 690225 mw---.wra~omo PDR ADOCK 05000237 G

PDR

m__

+

DIVISION OF COMPLIANCE MONTHLY REPORT, JANUARY 1969 s '

Eravo Corporatien, Ma-letta, Ohio - A quality control audit of the

. rwa Corporaticn was conducted ch January 7, 8, and 9 tc review piping acc. illes fecm specific systens of each of the follcwing projects:

irecr-n 2 an] 3; Quad Cities 1 and 2; Indian Point 2; and Tu" key Point 3...ii.

In addition, piping deficiencies found at varicus sites l

were investigated.

".e aucults of the audit indicate an kprovement in documentation anu co. ora truceacilny; however, cer tain poor practices were noted.

fir.ai incpe; tier was ccnsidered lax but steps have been taken to

rrea. ',r.Ja condition

.:n pracuicea of the purchaser's QC representativec were reviewed.

'E-A

':recden 2 el 3 an t Quad Citles 1 an'l 2) have writ. ten Jn-cp /

. prc tedures but its ancpection performance has been upcradic.

':nitel Er.gineers and Constructors (Indian Point 2) have no plar.ned e Mten inspection precedures and its inspection perfe r.ance is also poridic

.Rechtel (Turkey Point 3 and 4) maintains a full-tim reci-trJ. Inspecto: at Dravo who incpects 100% of every piping assembly is shipped.

La-

.