TTCD ES TABLE 3.6-1
>S gg CONTAINMENT ISOLATION VALVES nu
-e TESTABLE DURING
@co g
VALVE NUMBER FUNCTION PLANT OPERATION ISOLATION TIME gg g
(seconds) ou z
$20 U
D.
Containment Spray Actuation (Containment Isolation Barriers only) h M0 2053Af Containment Spray Pump A discharge - outside yes N.A.
MD 2053Bf Containment Spray Pump B discharge - outside yes N.A.
E.
Non-automatic Power Operated Valves MO 8702#(a)
RHR nomal suction inside no N.A.
MO 8701#(a)
RHR nomal suction inside no N.A.
w CV 8825#
RHR hot leg recirculation - inside no N.A.
2 M0 8703#
RHR hot leg recirculation -
os outside no N.A.
k M0 8835#
SIS discharge line - outside (cold leg) no N.A.
MO 8809A#
RHR pump "A" discharge - outside no N.A.
M0 88098#
RHR pump "B" discharge - outside no N.A.
M0 2069A SIS Recirculation Train "A" inside yes N.A.
M0 2052A SIS Recirculation Train "A" outside no N.A.
MD 8811A SIS Recirculation Train "A" outside no N.A.
M0 2069B SIS Recirculation Train "B" inside yes N.A.
M0 2052B SIS Recirculation Train "B" outside no N.A.
MO 8811B SIS Recirculation Train "B" -
outside no N.A.
Lal May be open during Mode 4 i