9 0

ENCLOSURE 1 PROPOSED TECHNICAL SPECIFICATIONS FOR SRQUOYAH NUCLEAR PLANT f

8203080614 820303 DR ADOCK 05000327 p

PDR

1 ys i

PROPOSED TECilNICAL SPECIFICATIONS SEQUOYAll NUCLEAR PLANT UNIT 1

~

l

t __

PLANT FACErTV ORQ1Ntf17@e-SEOuovi+4 StKt pe t# TE NDE N T g

43

.a M

CO I"~ tires &N OF--~

1 d

8 NUCLE AR POwCR l I OUAtrTV A SSU't ANCEe I

g AmeO COUPLIAreCE t _ _ ence _ _j pH 8""I uANAGLR p

TEOe4*C AL CHE.F FIELD OUALTTY l OU4lffY

- - - - _ _ _ _ _ _ _c_ S_tTE rF 1 A S';LM ANCE ST AFF $

ASSURANCE N'E uANAGLf4 g,

SA# L1 T f NL.#4 LHret.)

s cR.w

wt"wei 0ffsite OUAlfTY ASSURANCE SECTON Onsite OUALITY m

~ ~ ~ Mk hF OfV ASSLKLANCE COORDNATOR j NUCLEAR POWER OUALITY FIELD SERvCCS AS$fD4ANCE g

L _ _ Ja'"C."_ _ '

ENCnEERs I

j 8

9 e

ENGINEERING & OPERATIONS HEALTH & SAFETY SERVICES MAINTENANCE l

l l

l l

45515Y ANT ASSISTANT A$51$7 ANT

(__OmSONOr PLANT etANT etANT l

I SERV 1CES St.rERNTE NDENT SLPCRNTURNT 4 POWE.R SYSTEuS 8 SisTJtNTENUCNT L _ _OPUI ATONS______J l

r-- ; N---I r-------

l l

g g

I PUBLC SAFETY 8 e

3 uf DC AL uEDCAL SECLKWTY

---a 8

$CRVCES ENGe4E E R**G OPER A FONS 3

l uCCH ANIC AL NSTRUutvf ELE C TRC AL w^nTtNANCE u AnnN Am u A nTEN Am SECTON SECTON L.--_.

___J L_________I

,50 SECTON SECTON SECTON SUPERvSOR SUPERVfSOR SLPERytSOR SUPER N SUPERVISOR g

r - N N OF----

7 r-DivtSCN OF-----7 C

g g

HEALTN POWER

- g OMRTY e OCCLPATCNAL pqyggg STORES 9

y N aCAL R$

TECHNIC AL ENORS TECHNICAL ENGRS DEuCAL traf I MEALTM & SAFETY l 8

l L _ _& SLRVfCES OrER S

t________

____._s

,onoe.

,ORtuo.

,OREuCN Surm,504

,E C ro,,

SUPE pveSOR otArTSutM CRAFTSMEN CRAFTSMEN gag l

Div SON OF TR A UNG g

I NUCLE AR POWER JANTTORIAL &

[NGMEERNQ &

SMFT ENGe#EER

- - - - = * = - - -

g y

TE ST UNff SRO LABORER SERvlCES

@JPEKvaSOR SUP(RviSOR AS57 SarT l

l p_q

[Ncevt E R REACTOR sRo

  • SArETv n ANT u AN AGr utNT g

ENCTdEERNG UNIT ENCe.1rTrssG COuPLIANCE SERVICE S

[.

a fire protection Sur[xvcOR StrEnvuoR SuetRviSOR SurcRveOR Communication uN,7OeERATOR ReportInr' Figure 6.2-2

l l

f l

t l

l l

~

ADMINISTRATIVE CONTROLS 6.4 TRAINING 6.4.1 A retraining and replacement training program for the unit, staff shall be maintained under the direction of the appropriate Assistant Plant Superintendent and shall meet or exceed the requirements and reccommendations of Section 5.5 of ANSI N18.1-1971 and Appendix "A" of 10 CFR Part 55 and the supplemental requirements specified in Section A and C of Enclosure 1 of the March 28,1980 NRC letter to all licensees, and shall include familiarization with relevant ~

industry operational experience identified by the ISEG.

6.5 REVIEW AND AUDIT

~

5.5.0 The Manager of Power is responsible for the safe operation of all TVA power plants. The functional organization for Review and Audit is shown on Figure 6.2-1.

6.5.1 PLANT OPERATIONS REVIEW COMMITTEE (PORC)

FUNCTION 6.5.1.1 The PORC shall function to advise the Plant Superintendent on all matters related to nuclear safety.

COMPOSITION

6. 5.1. 2 The PORC shall be composed of the:

Chairman:

Plant Superintendent Member:

Operations Supervisor I

Member:

Engineering Supervisor Member:

Instrument Maintenance Supervisor Member:

Electrical Maintenance Supervisor Member:

Health Physicist M1mber:

Supervisor Quality Assurance Staff Member:

Mechanical Maintenance Supervisor l-l l -*

?^

i ]

SEQUOYAH - UNIT 1 6-7a

-l

ADMINISTRATIVE CONTROLS h.

Performance of special reviews, investigations or analyses and reports thereon as requested by the Plant Superintendent or the Nuclear Safety Review Board.

i.

Review of the Plant Physical Security Plan and implementing procedures and shall submit recommended changes to the Nuclear Safety Review Board.

f j.

Review of the Site Radiological Emergency Plan and implementing procedures and shall submit recommended changes to the Nuclear Safety Review Board.

k.

Review of every unplanned onsite release of radioactive material to the environs including the preparation and forwarding of reports covering evaluation, recommendations and disposition of the corrective action to prevent recurrence to the Director, Nuclear Power Division and to the Nuclear Safety Review Board.

1.

Review of changes to the radwaste treatment systems.

m.

Review of meeting minutes of the Radiological Assessment Review Committee (RARC).

AUTHORITY 6.5.1.7 The PORC shall:

ei Recommend in writing to the Plant Superintendent approval or disapproval of items considered under 6.5.1.6(a) through (d) above.

b.

Render determinations in writing with regard to whether or not each item considered under 6.5.1.6(a) through (d) above constitutes an unreviewed. safety question.

Provide written notification within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to the Director, Nuclear c.

Power Division and the Nuclear Safety Review Board of disagreement between the PORC and the Plant Superintendent; however, the Plant Superintendent shall have responsibility for resolution of such disagreements pursuant to 6.1.1 above.

RECORDS 6.5.1.8 The PORC shall maintain written minutes of each PORC meeting that, at a minimum, document the results of all PORC activities performed under the responsibility and authority provisions of these technical specifications.

Copies shall be provided to the Director, Nuclear Power Division and the Nuclear Safety Review Board.

6.5.2 NUCLEAR SAFETY REVIEW BOARD (NSRB) r FUNCTION 6.5.2.1 The NSRB shall function to provide independent review and audit of designated activities in the areas of:

SEQUDYAH - UNIT 1 6-9

ADMINISTRATIVE CONTROLS ALTERNATES 6.5.1.3 All alternate members shall be appointed in writing by the PORC Chairman to serve on a temporary basis; however, no more than two alternates shall participate as voting members in PORC activities at any one time.

MEETING FREOUENCY 6.5.1.4 The PORC shall meet at regular monthly intervals and as convened by the PORC Chairman or his designated alternate.

OUORUM

~

6.5.1.5 The minimum quorum of the PORC necessary for the perf#.aance of the PORC responsibility and authority provisions of these technical specifications shall consist of the Chairman or his designated alternate and five members including alternates.

RESPONSIBILITIES 6.5.1.6 The PORC shall be responsible for:

a.

Review of 1) all procedures required by Specification 6.8.1 and changes thereto, 2) all programs required by Specification 6.8.5 and changes thereto, 3) any other proposed procedures or changes

)

thereto as determined by the Plant Superintendent to affect nuclear safety.

b.

Review of all proposed tests and experiments that affect nuclear safety.

1 i

c.

Review of all proposed changes to Appendix "A" Technical Specifications.

d.

Review of all "roposed changes or modifications to unit systems or equipment that affect nuclear safety.

Investigation of all violations of the Technical Specifications e.

including the preparation and forwarding of reports covering evaluation and recommendations to prevent recurrence to the Director, Nuclear Po,<er Division and to the Chairman of the Nuclear Safety Review Beard.

f.

Review all written reports rc. quiring 24-hour notification to. the Cc: mission.

Review of unit operations to detect potential nuclear safety hazards.

g.

(

L l

SEQUOYAH - UNIT 1 6-8 l

a i

l l

O Qt b 9

e PROPOSED TECHNICAL SPECIFICATIONS SEQUOYAH NUCLEAR PLANT UNIT 2 7

t th t'1 FACtrTv OncAMEATVN-SEOuovAN SwtpraTINfit NT g

O v,

~ ~ E6N OY ~ '

DN

~

e NUCLE AR POWER

'0U ALITY A SSUR ANCE O

, ANO COuPtlANCE g

H3 L - _ EDE. _ J N

Wat4AGLR f ~ ~ ~ CW"~~

TECHW AL SUPPORT I

OU4UTY g

FELD OUALTTY 8

- - _ _ - - - - - = - _O_FF SrrE 8 ASSUFT ANCE ST AFF $

A SSLKIA NCE cn Onsnt t_-_

_._-2

%8ANAG(FI 1

e.Ut3eNoLNI D

Saf L T Y f NC.NL LHaNG

v. oui-Siruivism 0ffsitc

OUAtrTY ASSun ANCE

""~~~~ - " * - "

SECTON Onsite OUAlffY I

AS$mA~CE

-- o,v srO;rt>,,

OUAUTY COORON A TOR j NUCLEAR POWLR g

FELD SERvtCES 8 ASSURANCE b -

E" C"

_ _J l

ENCNEERS f

ENGINEERING & OPERATIONS HEALTH & SAFETY SERVICES MAINTENANCE I

I 1

A SSr3 T ANT ASSISTANT ASSa37 ANT c'-

DrVISON OF-----

rm PLANT PLANT PLANT 8

I SERVCES SLPERNTENDENT SUPCRflTDCENT I POWER SYSTEMS 4 STERNTENDOff L _ _OPER ATONS--.__

J l

r OfvtSON OF--___-

f"---------

)

l PUBLC S AFETY I e

l ufDeCAL WEDICAL SECLrtrry W

9 SERVICE S E NGt4E L NWG OPER A TONS g

l ME CH ANC AL IN S T HLMENT EL ECTRC AL SECTON SEC TION l_----__J L-__--____I PSO uaNTtNANCE uANTtNANCE u A e, TEN ANCE SE CTON SECT ON SEC TION SUPCRytSOR FUPERytSOR gyggvison surggvison SUPERvtSOR gno r - NtSON OF----

7 F - OlVISON OF-----7

~

C g

HEALTH power g

t OCCUPA TIONAL pqyg,gg STORES 9

PROPERTY

,33 g, TIQf4 CAL D4 GAS TECHNICAL ENGRS TECHNICAL ENCRS CHEMCL UNIT 0 NEALTH & $AFETY l 8

l L- & $[RylCES OPER A TON $


.2 n>nn<n rOREwee rOREuo.

SteLRviSOa St C noN Swt 84 VISOR M aWEN CRAFTsuCN CR AFTSME N g

________3 D ISON OF TRANNQ I

NUCLE AR POWER l

PERSONNEL M

'O E SHrf ENCHEER JANfTORIAL &

AD" L SEnvicr_S ST Ar_r_ j T[ST UNff SRO LABOAER SERVICES l

LEGEND:

SUPv wvr$0a ASST Sury l

l p___q ENcm4E ER lL.

_- l Offsite

  • Responsible for REACTOR spo
  • SArrTV n ANT M AN A GEMENT ENGHEEINQ UPa7 ENCNETT38G COMPLIANCE SERVICES 4

fire rotection SUPERytSOR SUPERv1SOR SUPERvlSOR SurtRviSOR Communication uNiTOPERATOR no Reporting

  • Figure 6.2-2

..v l

4 i

I ADMINISTRATIVE CONTROLS i

1 6.4 TRAINING i

6.4.1 A retraining and replacement training program for the unit' staff shall be niaintained under the direction of the appropriate Assistant Plant Superintendent and shall meet or exceed the requirements and reccommendations of Section 5.5 of ANSI N18.1-1971 and Appendix "A" of 10 CFR Part 55 and the supplemental requirementsspecifiedinSectionAan'dCofEnclosure1oftheMarch28,198g NRC letter to all licensees, and sha?' include familiarization with relevant' i

industry operational experience identified by the ISEC.

2

6. 5 REVIEW AND AUDIT j

6.5.0 The Manager of Power is responsible for the safe operation of all TVA

~

j power plants. The functional organization for Review and Audit is shown on Figure 6.2-1.

I 6.5.1 PLANT OPERATIONS REVIEW COMMITTEE (PORC) i FUNCTION 4

6.5.1.1 The PORC shall function to advise the Plant Superintendent on all 4

matters related to nuclear safety.

j COMPOSITION

]

6. 5'.1. 2 The PORC shall be composed of the:

Chairman:

Plant Superintendent

{

Member:

Operations Supervisor Member:

Engineering Supervisor Member:

Instrument Maintenance Supervisor Member:

Electrical Maintenance Supervisor i

Member:

Health Physicist j

Member:

Supervisor Quality Assurance Staff i

Member:

Mechanical Maintenance Supervisor l

l 1

i i

I 4

SEQUOYAH - UNIT 2 6-10

l

-l ADMINISTRdTIVECONTROLS ALTERNATES 6.5.1.3 All alternate members shall be appointed in writing by the PORC Chairman to serve on a temporary basis; however, no more than two alternates shall participate as voting members in PORC activities at any one time.

MEETING FRE00ENCY

6. 5.1. 4 The FORC shall meet at regular monthly intervals and as convened by the PORC Chairman or his designatec alternate. '

QUORUM i

6. 5.1. 5 The minimum quorum of the PORC necessary for the performance of the PORC responsibility and authority provisions of these technical specifications shall consist of the Chairman or his designated alternate and five members including alternates.

' RESPONSIBILITIES

6. 5.1. 6 Tne PORC shall be responsible for:

I a.

Review of 1) all procedures required by Specification 6.8.1_and I

changes thereto, 2) all programs required by Specification 6.8.5 and changes thereto, 3) any other proposed procedures or changes thereto as determined by the Plant Superintendent to affect nuclear safety.

b.

Review of all proposed tests and experiments that affect nuclear safety.

Review of all proposed changes to Appendix "A". Technical Specifications.

c.

d.

Review of all proposed changes or modifications to unit systems or equipment that' affect nuclear safety.

Investigation of all violations of the Technical Specifications e.

including the preparation and forwarding of reports covering evaluation and recommendations to prevent recurrence to the Director, Nuclear Power Division and to the Chairman of the riuclea.- Safety Review Board.

f.

Review all written reports requiring 24-hour notification to the Cc. ?.i s s i on.

. Review of unit operations to detect potential nuclear safety' hazards.

g.

fL SEQUOYAH - UNIT 2 6-11 4

r -- -, '

t ADMINISTRATIVE CONTROLS I

h.

Performan_e of special reviews, investigations or analyses and k

reports thereon as requested by the Plant Superintendent or the Nuclear Safety Review Board.

i.

Review of the Plant Physical Security Plan and implementing procedures i

and shall submit recommended changes to the Nuclear Safety Review Board.

j.

Review of the Site Radiological Emergency Plan and implementing procedures and shall submit recommended changes to the Nuclear Safety Review Board.

k.

Review of every unplanned onsite release of radioactive material to the environs including the preparation and forwarding of reports covering evaluation, recommendations and disposition of the corrective action to prevent recurrence to the Director, Nuclear Power Division and to the Nuclear Safety Review Board.

o.

1.

Peview of changes to the radwaste treatment systems.

m.

Review of meeting minutes of the Radiological Assessment Review Ccmaittee (RARC).

AUTHORITY 6.5.1.7 The PORC shall:

ri Recommend in writing to the Plant Superintendent approval or i

disapproval of items _ considered under 6.5.1.6(a) through (d) above.

)

b.

Render determinations in writing with regard,to whether or not each item considered under 6.5.1.6(a) through (d) above constitutes an a

unreviewed safety question.

Provide written notification within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> to the Director, Nuclear c.

Power Division and the Nuclear Safety Review Board of disagreement between the PORC and the Plant Superintendent; however, the Plant Superintendent shall have responsibility for resolution of such disagreements pursuant to 6.1.1 above.

RECORDS 6.5.1.8 The PORC shall maintain written minutes of each PORC meeting that, at 4

a minimum, document the results of all PORC activities performed under the responsibility and authority provisions of these technical specifications.

Copies shall be provided to the Director, Nuclear Power Division and the Nuclear. Safety Review Board.

6.5.2 NUCLEAR SAFETY REVIEW BOARD (NSRB)

FUNCTION 6.5.2.1 The NSRB shall function to provide independent review and audit of-

' designated activities in the areas of:

SEQUOYAH - UNIT 2 6-12

ENCLOSURE 2 JUSTIFICATION FOR PROPOSED CHANGES TO SEQUOYAH' NUCLEAR PLANT (SNP)

UNIT 1/2 TECHNICAL SPECIFICATIONS The purpose of this proposed change to the SNP unit 1 and 2 technical specifications to reflect the recent SNP reorganization and to make. the PORC membership consistent with other TVA plants. The reorganization within the Division of Nuclear Power (NUC PR) established three assistant Plant Superintendents as indicated on Figure 6.2-2.

Each of these superintendents is responsible for the training and/or retraining of that respective portion of the unit staff under his supervision.

4 f

+4Y~-