ML20041B027

From kanterella
Jump to navigation Jump to search
Advises That Util Concerning NUREG-0737 Item III.D.1.1 Re Leakage Outside Containment Was Inadvertently Docketed W/Several Extraneous Encls,Therefore,Ltr Should Be Removed from Docket.Appropriate Required Info Provided
ML20041B027
Person / Time
Site: Farley 
Issue date: 02/15/1982
From: Clayton F
ALABAMA POWER CO.
To: Varga S
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-3.D.1.1, TASK-TM NUDOCS 8202230178
Download: ML20041B027 (2)


Text

~

M:lling AddG:s Alabama Power Company 600 North 18:h Street Post Ofhce Box 2641 0,rmingham Alabama 35291 Tctephone 205 783-6081 b

F. L. Clayton, Jr.

d 'y70"l"'

Alabamalhver o

ne wuven vaac syxm February 15, 1982 Docket No. 50-364 c)

G Q

\\

Director, Nuclear Reactor Regulation MECgfYED U. S. Nuclear Regulatory Commission r

Washington, D. C.

20555 9-Sg

~h Attention:

Mr. S. A. Varga Gentlemen:

4 Joseph M. Farley Nuclear Plant - Unit 2 NUREG-0737, item III.D.1.1 Leakage Outside Containment On September 8, 1981 Alabama Power Company submitted a letter to the NRC entitled, " Joseph M. Farley Nuclear Plant - Unit 2, Leakage Outside Containment." This letter inadvertently was docketed with several extranecus enclosures.

It is requested that the above mentioned letter dated September 8, 1981 be removed from Docket No. 50-364. The paragraph below provides the appropriate required information contained in the original letter.

As required by NUREG-0737, item III.D.1.1 and the Joseph M. Farley 1

Nuclear Plant Unit 2 Safety Evaluation Report, Supplement No 5, the below listed leakage rates of systems outside containment are submitted.

The allowable leakage rate levels given are those levels at which Alabama Power Company feels additional investigation and/or further leakage re-duction would be advisable.

1.

Containment Spray System.

Allowable leakage is 0.25 GPM, Unit 2 leakage is 0 GPM (3 drops / min.).

2.

High Head Safety Injection (CVCS System). Allowable leakage is 1.0 GPM, Unit 2 leakage is 0 GPM.

3.

Low Head Safety Injection (RHR). Allowable leakage is 1.0 GPM, Unit 2 leakage is 0 GPM.

em Q

4.

Containment Atcosphere Sample System. Allowable leakage is g

go@

100 SCCM, Unit 2 leakage is 16.7 SCCM.

y ruo 5.

Sampling System.

Allowable leakage is 0.25 GPM, Unit 2

/6

(

liquid leakage is 0.0006 GPM. Allowable VCT gas leakage determined by soap bubble (Snoop) leak check is 500 SCCM, o

Unit 2 leakage is 0 SCCM.

W om 6.

Waste Gas System. Allowable leakage is 500 SCCM, Unit 2

@@a leakage is 0 SCCM.

76 Mr. 5. A. Varga U. S. Nuclear Regulatory Comission February 15, 1982 Page 2 7.

All relief. lines of systems covered under the leakage assess-ment program are satisfactory.

If you have any questions, please advise.

Yours very truly,

^

/

x

/

F. L. Clayton, Jr. (

FLCJr/ JAR:lsh cc: Mr. R. A. Thomas Mr. G. F. Trowbridge Mr. J. P. O'Reilly Mr. E. A. Reeves Mr. W. H. Bradford t

o a