ML20040F466

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Potentially Loose Antirotation Pins on Low Pressure Safety Injection Pumps & Containment Spray Pumps,Initially Reported 811230.Final Rept Will Be Submitted 820323
ML20040F466
Person / Time
Site: Palo Verde  
Issue date: 01/28/1982
From: Van Brunt E
ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR
To: Faulkenberry B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, ANPP-20014-GHD, NUDOCS 8202090231
Download: ML20040F466 (3)


Text

w Docket No. 50-528/529/530

~

)U

$0.55(e) Report SMTZWM ls*JMSE 3'C 62Gd33 MlC3d CODNM37 P. O. B OX 216 G 6 PHOENIX, ARIZON A 85036 January 28, 1982 ANPP-20014-GHD/BSK to IA U. S. Nuclear Regulatory Commission Region V Creekside Oaks Office Park e-.,..

1450 Maria Lane - Suite 210 t/

9 Walnut Creek, California 94596-5368 pgg g )gg

{

Attention:

Mr. B. H. Faulkenberry, Chief g,numamng % -10 NWgW" CT u Reactor Construction and Engineering Support Branch g

f, N

Subject:

Interim Report - DER 81-52

~

A 50.55(e) Potentially Reportable Deficiency Relating to Unit 1 Low Pressure Safety Injection Pumps and Containment Spray Pumps Have Potentially Loose Anti-Rotation Pins File:

82-019-026 D.4.33.2

Reference:

Telephone Conversation between J. Eckhardt and G. Duckworth on December 30, 1981

Dear Sir:

The NRC was notified of a potentially reportable deficiency in the referenced telephone conversation. At that time, it was estimated that a determination of reportability would be made within thirty (30) days.

Due to the extensive investigation and evaluation required, an Interim Report is attached.

It is now expected that this information will be finalized by March 23, 1982, at which time a complete report will be submitted.

Very truly C c(.'\\ cutk c

nat E. E. Van Brunt, Jr.

APS Vice President p.q

' ~ ~ "

Nuclear Projects ANPP Project Director Ad I ~ O L -.

EEVBJr/GHD:ske Attachement ec: See Attached Page 2 u-I rao2o90231 e2012e PDR ADOCK 05000528 S

PDR

, j rj

s U. S. Nuclear Regulatory Commission Attention:

Mr. B. H. Faulkenberry, Chief ANPP-20014-CHD/BSK January 28, 1982 Page 2 cc:

Richard DeYoung, Director Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission Washington, D. C.

20555 J. A. Roedel D. B. Fasnacht G. C. Andognini F. W. Hartley J. M. Allen A. C. Rogers B. S. Kaplan W. E. Ide J. Vorees J. A. Brand A. C. Gehr W. J. Stubblefield W. G. Bingham R. L. Patterson R. W. Welcher R. M. Grant D. R. Hawkinson L. E. Vorderbrueggen R. L. Greenfield Assistant Attorney General Bataan Memorial Building Santa Fe, New Mexico 87503 Ms. Patricia Lee Hourihan 6413 South 26th Street Phoenix, Arizona 85040 i

l i

I 1

w e

e INTERIM REPORT - DER 81-52 POTENTIAL REPORTABLE DEFICIENCY ARIZONA PUBLIC SERVICE COMPANY (APS)

PVNGS UNIT 1 I.

Potential Problem Combustion Engineering identified a Low Pressure Safety injection Pump failure at the Arkansas One plant.

Subsequent Combustion Engineering correspondence requested Bechtel to check and reinstall any loose Anti-Rotation Pins in the Low Presuure Safety Injection and Containment Spray Pumps manufactured by Ingersoll-Rand.

II.

Approach To and Status Of Proposed Resolution Bechtel has requested assistance from Combustion Engineering in evaluating and dispositioning this item.

III. Projected Completion of Corrective Action and Submittal of the Final Report Evaluation of this condition and submittal of the Final Report is forecast to be completed by March 23, 1982.

-