,r '

hp UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION BEFORE THE-ATOMIC SAFETY AND LICENSING BOARD In the Matter of

)

)

Docket Nos. 50-445 and TEXAS UTILITIES GENERATING

)

50-446~

COMPANY, et. al.

)

)

(Application for (COMANCHE PEAK STEAM ELECTRIC

)

Operating Licenses)

STATION, Units 1 and 2)

)

AFFIDAVIT OF CHUN-MONG JAN REGARDING CONTENTION 2 (VERIFICATION AND ACCEPTANCE OF COMPUTER CODES I, Chun-Mong Jan, being first duly sworn, do depose and state:

I am employed by Gibbs & Hill, Inc.,.in the position of Chief Engineer-Special Analysis.

.I. directed the use and. verification of the computer codes used by Gibbs & Hill in structural dynamic analyses of the buildings at Comanche Peak, as set forth below.

A statement of my educational and professional qualifications is attached I

to this affidavit.

The purpose of.this affidavit is to establish that certain computer codes specified by Gibbs & Hill in the Comanche Peak

~ Final Safety Analysis Report ("FSAR") use accepted engineering mathematical techniques and that these codes have been properly

' verified.

- 8201290417 g20126

'Y PDR ADOCK 05000445

. O-PDR

-e--

i

.t The codes which are the subject of this affidavit are the STARDYNE, SCONV_and SPECTRA codes.

The STARDYNE code is operated and maintained by Control Data Corporation (CDC).

CDC provides access to the STARDYNE code to Gibbs & Hill and other users through its service bureau.

The SCONV.and SPECTRA codes were developed by Gibbs & Hill.

The STARDYNE code is one of the largest and most powerful i

and widely recognized codes in the public domain for performing _ structural analyses'of buildings.

It has been employed for approximately twelve (12) years by many engineering organizations'in performing a variety of static and dynamic structural analyses.

Gibbs & Hill has used the code for eight (8) years in performing static and dynamic analyses of buildings.

As a result, Gibbs & Hill believes that STARDYNE satisfies NRC Standard Review Plan acceptance criteria as "a recognized program in the public domain that has had sufficient history'of use to justify its.

applicability and validity without further demonstration."

i.

The SCONV code uses convolution' integration to solve dynamic problems;for linear elastic systems.

The integration technique employed by the code is recognized and used in'the i

field of. dynamic analysis.

Gibbs & Hill has verified this code by comparing results obtained from sample problems t

using the code of CSMP, which is one of the well I

recognized and accepted IBM scientific subrontine programs.

(

f, e

e The SPECTRA code is a subroutine which provides spectral accelerations corresponding to a set of specified pairs of frequencies and the associated modal damping values through the interpolation of the prescribed ground response spectra.

Gibbs & Hill has verified this code by comparison of results obtained from SPECTRA with those interpolated from NRC Regulatory Guide 1.60.

'f@1ef [

Chun-Mong Jan Sworn to before me this 15th day of January 1982.

W Y

)%c Notary Public

: ::. w::.n.u::
c res rauc. s :m ne nur reu
  • a 727 L3 C & ftei m.*:n
en. Ccu.ty h x;.:..o::
a d :.2 '!er6 'M 1S%

e' CHUN-MONG JAN, D.Sc, PE Chief Engineer - Specia'l Analysis GIBBS & HILL, INC'.

I 1959 National Taiwan University - Bachelor of Science, Civil Engineering 1964 Brigham Young University - Master of Science, Structural Engineering 1971

- Columbia University - Doctorate, Structural Mechanics Registered Professional Engineer in New York, New Jersey and Taiwan 1979 - Date - Chief Engineer-Special Analysis, cibbs & Hill, Inc., New York, New York, direction and supervision of structural static and' dynamic analyses and equipment seismic qualifications'of nuclear and fossil power plants.

1976 - 1979 - Assistant Chief Structural Engineer, Gibbs & Hill, Inc.,

New York, New York, supervision of dynamic analyses and computerized structural design for nuclear power plants.

1974 - 1976 Staff Engineer - Structural, Gibbs & Hill, Inc., New York, New York, supervision of dynamic analyses and computerized structural design for nuclear power plants.

1972 - 1974 Senior Engineer - Structural, Gibbs & Hill, Inc., New York, New York, supervision of seismic and other dynamic stress analyses for structural components of nuclear power plants.

1971 - 1972 Assistant Engineer - Structural', Gibbs & Hill, Inc., New York, New York,. seismic analysis of reactor safeguard building and reactor. coolant loop system; development of floor response spectra for several projects.

1969 - 1971 - Research Assistant and Research Associate, Columbia University, i

New York, New York, development of simulation technique for generating a multivariate or multidimensional random process with application to earthquake and wind-gust problems, F

teaching graduate courses in random vibration and finite element method; development of computer programs for engineering applications; structural dynamics and structural reliability problems.

1965 - 1969 - Structural Designer, Gibbs & Hill, Inc., New York, New York, overall and detailed structural design of nuclear power plants, including foundation mat, reactor containment (steel, concrete or prestressed), shear wall, and containment openings.

=,

y ry-=

7=-

w. e CliUN-MONG JAN, D.Sc, PE 1964 - 1965 Structural Engineer, Vollmer Associates, New York, New York, structural design for Saratoga Performing Arts Center and for various highway bridges.

1961 - 1963 - Assistant Civil Engineer, Engineering Section, Bank of Taiwan, Taipei, Taiwan, structural design, cost estimate, specifications and construction supervision, headquarters complex, Bank of Taiwan.

__